• Title/Summary/Keyword: Power of two side test

Search Result 54, Processing Time 0.036 seconds

Power analysis attack resilient block cipher implementation based on 1-of-4 data encoding

  • Shanmugham, Shanthi Rekha;Paramasivam, Saravanan
    • ETRI Journal
    • /
    • v.43 no.4
    • /
    • pp.746-757
    • /
    • 2021
  • Side-channel attacks pose an inevitable challenge to the implementation of cryptographic algorithms, and it is important to mitigate them. This work identifies a novel data encoding technique based on 1-of-4 codes to resist differential power analysis attacks, which is the most investigated category of side-channel attacks. The four code words of the 1-of-4 codes, namely (0001, 0010, 1000, and 0100), are split into two sets: set-0 and set-1. Using a select signal, the data processed in hardware is switched between the two encoding sets alternately such that the Hamming weight and Hamming distance are equalized. As a case study, the proposed technique is validated for the NIST standard AES-128 cipher. The proposed technique resists differential power analysis performed using statistical methods, namely correlation, mutual information, difference of means, and Welch's t-test based on the Hamming weight and distance models. The experimental results show that the proposed countermeasure has an area overhead of 2.3× with no performance degradation comparatively.

The Effect of Dong-gi Acupuncture(DGA) on Rehabilitation after Stroke (중풍(中風) 편마비(偏痲痺) 환자(患者)의 기능적 회복에 있어 침시술(鍼施術) 시(時) 동기요법(動氣療法)의 효과)

  • Lee, Yun-Ju;Jang, Jun-Ho;Park, Seon-Kyeong;Kim, Min-Cheul
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.15 no.2
    • /
    • pp.155-167
    • /
    • 2005
  • Objectives : The purpose of this study is evaluate of the effect of Dong-gi Acupuncture(DGA) on rehabilitation after stroke. Methods : 32 patients who had a stroke of paralysis were randomized into two groups. 17 patients were treated with DGA on sound side combined active or passive exercise on affected side. The other 15 patients were exclusive DGA group and the method retaining needles on acupoints of affected side for about 20 minutes were applied. We evaluated by Manual muscle test, Range Of Motion(ROM), Visual Analog Scale(VAS) and Modified Barthel index(MBI) before treatment, after 10 days and after 20 days. Results : In terms of power of lower limb, active ROM of shoulder abduction and MBI, the sample group showed statistically significant improve. In terms of power of lower limb ROM of hip joint abduction and affected side pain, significant difference between two groups was not shown. Conclusions : In this clinical study, Dong-gi Acupuncture therapy can be used for improving the power of upper limb, active ROM of shoulder abduction and MBI score after hemiplegic stroke.

Power Analysis for Tests Adjusted for Measurement Error

  • Heo, Sun-Yeong;Eltinge, John L.
    • 한국데이터정보과학회:학술대회논문집
    • /
    • 2003.05a
    • /
    • pp.1-14
    • /
    • 2003
  • In man cases, the measurement error variances may be functions of the unknown true values or related covariate. In some cases, the measurement error variances increase in proportion to the value of predictor. This paper develops estimators of the parameters of a linear measurement error variance function under stratified multistage random sampling design and additional conditions. Also, this paper evaluates and compares the power of an asymptotically unbiased test with that of an asymptotically biased test. The proposed method are applied to blood sample measurements from the U.S. Third National Health and Nutrition Examination Survey(NHANES III)

  • PDF

Fabrication and test of a miniaturized superconducting DC cable system (축소형 초전도 직류 케이블 시스템의 제작 및 시험)

  • Kim, Jin-Geun;Kim, Sung-Kyu;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.794-795
    • /
    • 2011
  • The DC side voltage and current of a HVDC transmission system are directly affected by non-linear switching devices such as the thyristor valve which causes real power losses, even under the superconducting conditions of a high temperature superconducting (HTS) power cable. This paper deals with the development of miniaturized superconducting DC cable system. The authors designed and fabricated two thyristor converters for DC transmission system. One is operated as a rectifier and the other is an inverter. The HTS model cable was connected between the DC side of the rectifier and inverter. Real DC transport current and voltage were applied to the miniaturized HTS DC cable. Experimental results are discussed in detail.

  • PDF

Tidal Current Power Generation by a Darrieus Type Water Turbine at the Side of a Bridge Pier

  • Kyozuka, Yusaku;Wakahama, Hisanori
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.99-104
    • /
    • 2006
  • There are several advantages to make use of a bridge pier for the tidal power generation. Current velocity increases near the pier, therefore the tidal power generation becomes more efficient because the power is proportional to the cubic of the current velocity. The pier is convenient for access and maintenance of the hydraulic turbine and the power unit. The project is now underway at the Ikitsuki Bridge in Tatsuno-Seto Strait of Nasasaki Prefecture, where the tidal current was measured by the bottom mount ADCP for almost one year. Model experiments for a Darrieus water turbine with two and three straight blades were carried out in the circulating water channel, in which the power coefficients of the turbine were obtained as a function of blade section and the attaching angle of a blade to the rotor. Those experimental results are discussed to obtain an optimum Darrieus turbine for tidal power generation.

  • PDF

A Study on the Fluid Mixing Analysis for Proving Shell Wall Thinning of a Feedwater Heater (급수가열기 동체 감육 현상 규명을 위한 유동해석 연구)

  • Kim, Kyung-Hoon;Hwang, Kyeong-Mo;Kim, Sang-Nyung
    • Journal of ILASS-Korea
    • /
    • v.9 no.4
    • /
    • pp.24-30
    • /
    • 2004
  • Feedwater flowing tube side of number 5 high pressure feedwatrr heaters was heated by extracting steam from high pressure turbine and draining water from moisture separators and number 6 high pressure feedwater heaters and supplied into steam generators. Because the extracting steam from the high pressure turbine is two phase fluid of high temperature, high pressure, and high speed and flows to inverse direction after impinging to impingement baffle. the shell wall of the number 5 high pressure feedwater heater may be affected by flow accelerated corrosion. On May 14, 1999, Point Beach Nuclear Plant (PBNP) with operating at full power experienced a steam leak from rupture of shell side of number 4B feedwater heater. Also, d domestic nuclear power plant experienced a severe wall thinning of shell side of number 5A and 5B feedwater heaters. This paper describes the fluid mixing analysis study using PHOENICS code in order to get at the root of the shell wall thinning of the feedwater heaters. The sections included in the fluid mixing analysis model are around the number 5h feedwater heater shell including the extracting pipeline. To identify the relation between the local velocities and wall thinning. the local velocities according to the analysis results were compared with the distribution of the shell wall thickness by ultrasonic test.

  • PDF

Influence of Pilates on physical factors related to exercise performance

  • Yu, Jae-Ho;Lee, Gyu-Chang
    • The Journal of Korean Physical Therapy
    • /
    • v.23 no.3
    • /
    • pp.57-63
    • /
    • 2011
  • Purpose: The purposes of this study were to investigate the effectiveness of Pilates exercise on Fitness Factors related to motor performance including flexibility, agility, power, balance, and muscle endurance. Methods: Forty subjects were randomly allocated to one of two groups. The Pilates group did Pilates exercises 3 times a week for 8weeks, 60 minutes each time, and submitted to evaluation of protocols to assess sitting and reaching tests, a standing broad jump test, a side step test, a balance test using a Biodex Stability System, and muscle endurance using CSMI. Results: The Pilates group (n=20) participated in Pilates exercises three times in a week for eight weeks. The results show significant post-test differences in the Pilates group in the following areas: flexibility, agility, power, balance and muscle endurance. There was no significant increase in the control group. Post-exercise, there was no significant difference between the Pilates and control group. Conclusion: The Pilates method can offer significant improvement in personal flexibility, agility, power, balance, and muscle endurance. This study suggests that individuals can improve their Fitness Factors related to motor performance using Pilates exercises that do not require equipment or a high degree of skill. Further study is required to quantify the benefits of Pilates exercise.

Development of a Novel 30 kV Solid-state Switch for Damped Oscillating Voltage Testing System

  • Hou, Zhe;Li, Hongjie;Li, Jing;Ji, Shengchang;Huang, Chenxi
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.786-797
    • /
    • 2016
  • This paper describes the design and development of a novel semiconductor-based solid-state switch for damped oscillating voltage test system. The proposed switch is configured as two identical series-connected switch stacks, each of which comprising 10 series-connected IGBT function units. Each unit consists of one IGBT, a gate driver, and an auxiliary voltage sharing circuit. A single switch stack can block 20 kV-rated high voltage, and two stacks in series are proven applicable to 30 kV-rated high voltage. The turn-on speed of the switch is approximately 250 ns. A flyback topology-based power supply system with a front-end power factor correction is built for the drive circuit by loosely inductively coupling each unit with a ferrite core to the primary side of a power generator to obtain the advantages of galvanic isolation and compact size. After the simulation, measurement, and estimation of the parasitic effect on the gate driver, a prototype is assembled and tested under different operating regimes. Experimental results are presented to demonstrate the performance of the developed prototype.

An Experimental Study on the Fire Investigation to the Broken Plane Types of Glass (유리 파단면의 화재감식에 관한 실험적 연구)

  • Mun, Yong-Soo;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.4
    • /
    • pp.105-109
    • /
    • 2008
  • The purpose of this study is to distinguish the causes of broken glass on doors or windows when it is originally kept among the remains on the floor in fire site - whether it was broken due to heating or outer power-through test and characteristics of the broken plane including the pattern on the plane. Addition to it, the study tries to find characteristics to judge the point and direction of breakdown through the analysis of glass broken by outer power. With two assumed causes - a) breakdown due to heating and b) breakdown due to outer power-3 pieces of glass plates ($30cm{\times}30cm{\times}5mm$) were tested for each case, getting the results as following: First, for the glass broken due to the change of temperature, the broken plane is of slow and smooth curve without any pattern. Second, for the glass broken due to outer power, with the impact point as the center, the glass shows breakdown of radial type and the side shows breakdown of near-perpendicular type. The far the broken piece is from the impact point, the bigger the size is. The broken piece at the impact point is of long triangle type and the two long planes of the triangle shows semi-arc with the center of breakdown point and the other plane shows opposite pattern. Third, when glass that is damaged by outer power is heated, damaged forms and side patterns of the glass that is damaged by outer power are heated and disappeared.

Speed Control Of The Magnet Gear-Based Speed Reducer For Non-contact Power Transmission (비접촉 동력 전달을 위한 마그네트 기어 기반 감속기의 속도 제어에 관한 연구)

  • Jung, Kwang Suk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.7
    • /
    • pp.380-388
    • /
    • 2016
  • Using the magnet gear, it is possible to transmit power without mechanical contact. As the drive shaft in a magnet gear-based speed reducer system is isolated from the drive shaft, the system is a two-inertia resonance system that should cope with an external load with the limited air-gap stiffness. On the other hand, the drive shaft or low-speed side is controlled only by the torque of the drive shaft through an air-gap, and the excessive oscillation or the slip can then be generated because of an abrupt disturbance that is different from the general mechanical gear system. Therefore, the disturbance loaded at the low speed side should be measured or estimated, and considered in the control of the driving shaft. This paper proposes a novel full-state feedback controller with a reduced-order observer for the speed reducer system using a magnet gear with a unified harmonic modulator. The control method was verified by simulation and experiment. To estimate the load at the low speed side, a novel observer was designed, in which the new state variable is introduced and the new state equation is formulated. Using a full-state feedback controller including the observer, the test result against disturbance was compared with two D.O.F PI speed controllers. The pole slip was compensated within relatively a short time, and the simulation result about the estimated variable shows a similar tendency to the test result. The test results showed that the magnet gear-based reducer can be applied to an accurate servo system.