Power analysis attack resilient block cipher implementation based on 1-of-4 data encoding

  • Shanmugham, Shanthi Rekha;Paramasivam, Saravanan
    • ETRI Journal
    • /
    • 제43권4호
    • /
    • pp.746-757
    • /
    • 2021
  • Side-channel attacks pose an inevitable challenge to the implementation of cryptographic algorithms, and it is important to mitigate them. This work identifies a novel data encoding technique based on 1-of-4 codes to resist differential power analysis attacks, which is the most investigated category of side-channel attacks. The four code words of the 1-of-4 codes, namely (0001, 0010, 1000, and 0100), are split into two sets: set-0 and set-1. Using a select signal, the data processed in hardware is switched between the two encoding sets alternately such that the Hamming weight and Hamming distance are equalized. As a case study, the proposed technique is validated for the NIST standard AES-128 cipher. The proposed technique resists differential power analysis performed using statistical methods, namely correlation, mutual information, difference of means, and Welch's t-test based on the Hamming weight and distance models. The experimental results show that the proposed countermeasure has an area overhead of 2.3× with no performance degradation comparatively.

중풍(中風) 편마비(偏痲痺) 환자(患者)의 기능적 회복에 있어 침시술(鍼施術) 시(時) 동기요법(動氣療法)의 효과 (The Effect of Dong-gi Acupuncture(DGA) on Rehabilitation after Stroke)

  • 이윤주;장준호;박선경;김민철
    • 한방재활의학과학회지
    • /
    • 제15권2호
    • /
    • pp.155-167
    • /
    • 2005
  • Objectives : The purpose of this study is evaluate of the effect of Dong-gi Acupuncture(DGA) on rehabilitation after stroke. Methods : 32 patients who had a stroke of paralysis were randomized into two groups. 17 patients were treated with DGA on sound side combined active or passive exercise on affected side. The other 15 patients were exclusive DGA group and the method retaining needles on acupoints of affected side for about 20 minutes were applied. We evaluated by Manual muscle test, Range Of Motion(ROM), Visual Analog Scale(VAS) and Modified Barthel index(MBI) before treatment, after 10 days and after 20 days. Results : In terms of power of lower limb, active ROM of shoulder abduction and MBI, the sample group showed statistically significant improve. In terms of power of lower limb ROM of hip joint abduction and affected side pain, significant difference between two groups was not shown. Conclusions : In this clinical study, Dong-gi Acupuncture therapy can be used for improving the power of upper limb, active ROM of shoulder abduction and MBI score after hemiplegic stroke.

Power Analysis for Tests Adjusted for Measurement Error

  • 허순영
    • 한국데이터정보과학회:학술대회논문집
    • /
    • 한국데이터정보과학회 2003년도 춘계학술대회
    • /
    • pp.1-14
    • /
    • 2003
  • In man cases, the measurement error variances may be functions of the unknown true values or related covariate. In some cases, the measurement error variances increase in proportion to the value of predictor. This paper develops estimators of the parameters of a linear measurement error variance function under stratified multistage random sampling design and additional conditions. Also, this paper evaluates and compares the power of an asymptotically unbiased test with that of an asymptotically biased test. The proposed method are applied to blood sample measurements from the U.S. Third National Health and Nutrition Examination Survey(NHANES III)

  • PDF

축소형 초전도 직류 케이블 시스템의 제작 및 시험 (Fabrication and test of a miniaturized superconducting DC cable system)

  • 김진근;김성규;박민원;유인근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.794-795
    • /
    • 2011
  • The DC side voltage and current of a HVDC transmission system are directly affected by non-linear switching devices such as the thyristor valve which causes real power losses, even under the superconducting conditions of a high temperature superconducting (HTS) power cable. This paper deals with the development of miniaturized superconducting DC cable system. The authors designed and fabricated two thyristor converters for DC transmission system. One is operated as a rectifier and the other is an inverter. The HTS model cable was connected between the DC side of the rectifier and inverter. Real DC transport current and voltage were applied to the miniaturized HTS DC cable. Experimental results are discussed in detail.

  • PDF

Tidal Current Power Generation by a Darrieus Type Water Turbine at the Side of a Bridge Pier

  • Kyozuka, Yusaku;Wakahama, Hisanori
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2006년 창립20주년기념 정기학술대회 및 국제워크샵
    • /
    • pp.99-104
    • /
    • 2006
  • There are several advantages to make use of a bridge pier for the tidal power generation. Current velocity increases near the pier, therefore the tidal power generation becomes more efficient because the power is proportional to the cubic of the current velocity. The pier is convenient for access and maintenance of the hydraulic turbine and the power unit. The project is now underway at the Ikitsuki Bridge in Tatsuno-Seto Strait of Nasasaki Prefecture, where the tidal current was measured by the bottom mount ADCP for almost one year. Model experiments for a Darrieus water turbine with two and three straight blades were carried out in the circulating water channel, in which the power coefficients of the turbine were obtained as a function of blade section and the attaching angle of a blade to the rotor. Those experimental results are discussed to obtain an optimum Darrieus turbine for tidal power generation.

  • PDF

급수가열기 동체 감육 현상 규명을 위한 유동해석 연구 (A Study on the Fluid Mixing Analysis for Proving Shell Wall Thinning of a Feedwater Heater)

  • 김경훈;황경모;김상녕
    • 한국분무공학회지
    • /
    • 제9권4호
    • /
    • pp.24-30
    • /
    • 2004
  • Feedwater flowing tube side of number 5 high pressure feedwatrr heaters was heated by extracting steam from high pressure turbine and draining water from moisture separators and number 6 high pressure feedwater heaters and supplied into steam generators. Because the extracting steam from the high pressure turbine is two phase fluid of high temperature, high pressure, and high speed and flows to inverse direction after impinging to impingement baffle. the shell wall of the number 5 high pressure feedwater heater may be affected by flow accelerated corrosion. On May 14, 1999, Point Beach Nuclear Plant (PBNP) with operating at full power experienced a steam leak from rupture of shell side of number 4B feedwater heater. Also, d domestic nuclear power plant experienced a severe wall thinning of shell side of number 5A and 5B feedwater heaters. This paper describes the fluid mixing analysis study using PHOENICS code in order to get at the root of the shell wall thinning of the feedwater heaters. The sections included in the fluid mixing analysis model are around the number 5h feedwater heater shell including the extracting pipeline. To identify the relation between the local velocities and wall thinning. the local velocities according to the analysis results were compared with the distribution of the shell wall thickness by ultrasonic test.

  • PDF

Influence of Pilates on physical factors related to exercise performance

  • Yu, Jae-Ho;Lee, Gyu-Chang
    • The Journal of Korean Physical Therapy
    • /
    • 제23권3호
    • /
    • pp.57-63
    • /
    • 2011
  • Purpose: The purposes of this study were to investigate the effectiveness of Pilates exercise on Fitness Factors related to motor performance including flexibility, agility, power, balance, and muscle endurance. Methods: Forty subjects were randomly allocated to one of two groups. The Pilates group did Pilates exercises 3 times a week for 8weeks, 60 minutes each time, and submitted to evaluation of protocols to assess sitting and reaching tests, a standing broad jump test, a side step test, a balance test using a Biodex Stability System, and muscle endurance using CSMI. Results: The Pilates group (n=20) participated in Pilates exercises three times in a week for eight weeks. The results show significant post-test differences in the Pilates group in the following areas: flexibility, agility, power, balance and muscle endurance. There was no significant increase in the control group. Post-exercise, there was no significant difference between the Pilates and control group. Conclusion: The Pilates method can offer significant improvement in personal flexibility, agility, power, balance, and muscle endurance. This study suggests that individuals can improve their Fitness Factors related to motor performance using Pilates exercises that do not require equipment or a high degree of skill. Further study is required to quantify the benefits of Pilates exercise.

Development of a Novel 30 kV Solid-state Switch for Damped Oscillating Voltage Testing System

  • Hou, Zhe;Li, Hongjie;Li, Jing;Ji, Shengchang;Huang, Chenxi
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.786-797
    • /
    • 2016
  • This paper describes the design and development of a novel semiconductor-based solid-state switch for damped oscillating voltage test system. The proposed switch is configured as two identical series-connected switch stacks, each of which comprising 10 series-connected IGBT function units. Each unit consists of one IGBT, a gate driver, and an auxiliary voltage sharing circuit. A single switch stack can block 20 kV-rated high voltage, and two stacks in series are proven applicable to 30 kV-rated high voltage. The turn-on speed of the switch is approximately 250 ns. A flyback topology-based power supply system with a front-end power factor correction is built for the drive circuit by loosely inductively coupling each unit with a ferrite core to the primary side of a power generator to obtain the advantages of galvanic isolation and compact size. After the simulation, measurement, and estimation of the parasitic effect on the gate driver, a prototype is assembled and tested under different operating regimes. Experimental results are presented to demonstrate the performance of the developed prototype.

유리 파단면의 화재감식에 관한 실험적 연구 (An Experimental Study on the Fire Investigation to the Broken Plane Types of Glass)

  • 문용수;공하성
    • 대한안전경영과학회지
    • /
    • 제10권4호
    • /
    • pp.105-109
    • /
    • 2008
  • The purpose of this study is to distinguish the causes of broken glass on doors or windows when it is originally kept among the remains on the floor in fire site - whether it was broken due to heating or outer power-through test and characteristics of the broken plane including the pattern on the plane. Addition to it, the study tries to find characteristics to judge the point and direction of breakdown through the analysis of glass broken by outer power. With two assumed causes - a) breakdown due to heating and b) breakdown due to outer power-3 pieces of glass plates ($30cm{\times}30cm{\times}5mm$) were tested for each case, getting the results as following: First, for the glass broken due to the change of temperature, the broken plane is of slow and smooth curve without any pattern. Second, for the glass broken due to outer power, with the impact point as the center, the glass shows breakdown of radial type and the side shows breakdown of near-perpendicular type. The far the broken piece is from the impact point, the bigger the size is. The broken piece at the impact point is of long triangle type and the two long planes of the triangle shows semi-arc with the center of breakdown point and the other plane shows opposite pattern. Third, when glass that is damaged by outer power is heated, damaged forms and side patterns of the glass that is damaged by outer power are heated and disappeared.

비접촉 동력 전달을 위한 마그네트 기어 기반 감속기의 속도 제어에 관한 연구 (Speed Control Of The Magnet Gear-Based Speed Reducer For Non-contact Power Transmission)

  • 정광석
    • 한국산학기술학회논문지
    • /
    • 제17권7호
    • /
    • pp.380-388
    • /
    • 2016
  • 마그네트 기어를 이용하면 기계적인 접촉없이 동력을 전달할 수 있다. 마그네트 기어 기반 감속 시스템에서 종동축은 구동축으로부터 분리되어있기 때문에 시스템은 제한된 공극 강성으로 부하 변화에 대응해야하는 2관성 공진 시스템이다. 종동축 즉, 저속측은 구동축 인가 토크만으로 제어되고 갑작스런 외란에 따라 일반적인 기계식 기어 시스템과 달리 과도한 진동이나 슬립이 발생할 수 있다. 따라서 저속측에 인가되는 부하 등의 외란은 실시간으로 측정되거나 추정되어야 한다. 본 논문에서는 고조파 조절기 일체형 마그네트 기어를 이용한 감속 시스템의 저속측 속도 제어를 위한 전상태 되먹임 제어기를 제안하고 이를 전산 모의 시험과 실험을 통해 검증하였다. 저속측 부하를 추정하기 위해 새로운 상태변수를 도입하여 관측기를 설계하였으며 이를 기반으로 하는 전상태 제어기를 통한 외란에 대한 강건성은 2자유도 PI 속도 제어기와 비교하였다. 상대적으로 짧은 시간안에 극의 슬립이 보정되는 것을 확인하였으며 추정된 변수는 실제 측정 결과와 유사한 경향을 나타내었다. 이러한 결과는 마그네트 기어 감속기의 서보 시스템으로의 응용 가능성을 담보해주는 결과인 것으로 판단된다.