• Title/Summary/Keyword: Power network management

Search Result 757, Processing Time 0.032 seconds

An Optimization Algorithm for the Maximum Lifetime Coverage Problems in Wireless Sensor Network

  • Ahn, Nam-Su;Park, Sung-Soo
    • Management Science and Financial Engineering
    • /
    • v.17 no.2
    • /
    • pp.39-62
    • /
    • 2011
  • In wireless sensor network, since each sensor is equipped with a limited power, efficient use of the energy is important. One possible network management scheme is to cluster the sensors into several sets, so that the sensors in each of the sets can completely perform the monitoring task. Then the sensors in one set become active to perform the monitoring task and the rest of the sensors switch to a sleep state to save energy. Therefore, we rotate the roles of the active set among the sensors to maximize the network lifetime. In this paper, we suggest an optimal algorithm for the maximum lifetime coverage problem which maximizes the network lifetime. For comparison, we implemented both the heuristic proposed earlier and our algorithm, and executed computational experiments. Our algorithm outperformed the heuristic concerning the obtained network lifetimes, and it found the solutions in a reasonable amount of time.

A Study on the Implementation of Geographic Information System for an Intelligent Power Distribution Network with Location Informations of Power Line Communication-based Automatic Meter Reading System (전력선통신 기반 저압원격검침 시스템의 공간 정보를 활용한 지능형 배전망 지리정보시스템 구축에 관한 연구)

  • Seo, Chung-Ki;Lee, Seung-Gol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.3
    • /
    • pp.365-369
    • /
    • 2015
  • In this paper, geographic information system(GIS) for an intelligent power distribution network was implemented with location informations acquired from automatic meter reading system, where the location informations of power line communication(PLC) modems installed at customer side were collected at data concentration units(DCUs) of headend equipment via PLC and then were transmitted to front end processor server. By displaying the connection status of the power distribution network on GIS map, operation of advanced metering infrastructure(AMI) or management of power grid system could be performed intuitionally and in real time, because the configuration state of the power grid could be easily monitored. The feasibility of the proposed system was confirmed with the especially constructed laboratory-level test bed and the verification test of the system will be carried out for a real power distribution network.

Field Trial of Power Line Communication Access Network over Medium Voltage Power Distribution Grid (고압 배전선로를 이용한 고속 전력선 통신 가입자망 구축 연구)

  • Lee, Jae-Jo;Oh, Hui-Myoung;Park, Young-Jin;Kim, Kwan-Ho;Lee, Dae-Young
    • Proceedings of the KIEE Conference
    • /
    • 2005.07d
    • /
    • pp.3040-3042
    • /
    • 2005
  • During the last several years, interest in broad-band power line communications (PLC) has been grown over medium voltage(MV) power distribution lines as well as low voltage lines. This paper introduces a medium voltage PLC test field that is set up in the suburbs of Euiwang city in Korea. This test field could be used not only for the measurement of communication channel environment but also for internet service. This paper shows the configuration of medium voltage test field with network devices like MV signal coupler and the results of channel environment like noise and impulse response. It also shows the service performance of PLC access network through network management system.

  • PDF

A study for PDMS Application Scheme of Digital S/S with IEC61850 Base (IEC61850 기반 디지털 변전시스팀에서의 PDMS 적용 방안에 관한 연구)

  • Lee, D.C.;Kim, H.S.;Bae, U.L.;Min, B.W.
    • Proceedings of the KIEE Conference
    • /
    • 2006.05a
    • /
    • pp.78-82
    • /
    • 2006
  • The Partial Discharge Monitoring System is technology which is available to measure & analysis the partial discharge of Power equipment. This technology is in the limelight as a pre-forecast system of equipment defect but there are some problems like no protocol standard, layered network management and the limitation of physical size. This paper presents whole system structure includes engineering centers, LN(Logical Node) to apply PDMS for, base-digital substation system, ICE61850 compatible Condition Monitoring &Diagnosis (CMD), Local Unit(LU), Intelligent Electronic Device (IED) for the solution scheme of these limitations.

  • PDF

A Design of PC Power-Saving System Security Using IP Address Restriction (IP 주소 제한을 이용한 PC 절전 시스템 보안 설계)

  • Kim, Hong Yoon
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.9 no.3
    • /
    • pp.49-57
    • /
    • 2013
  • Power-saving PC software enables the inexpensive power control, but the installation of the power-saving software in all computers in the organization is not an easy task. Computer users in the organization are usually not cooperative as they do not think the power-saving cost is directly related to themselves. The PC power-saving system provides advantage to driving active participation in which users installs the power saving software by restricting IP address through the power management server. However, the problem with this approach is the security vulnerability to IP spoofing attacks, therefore we need to solve the problem that disrupt the entire network system rather than saving electric power. This paper proposes the security authentication system that can implement the efficiency saving power by providing high security for the members' computer system of the public institutions based on the PC power-saving system. Also, by analyzing it in comparison with other method, it is possible to check that the prospects of safety and efficiency are strengthened.

A Simple Power Management Scheme with Enhanced Stability for a Solar PV/Wind/Fuel Cell Fed Standalone Hybrid Power Supply using Embedded and Neural Network Controller

  • Thangavel, S.;Saravanan, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1454-1470
    • /
    • 2014
  • This paper propose a new power conditioner topology with intelligent power management controller that integrates multiple renewable energy sources such as solar energy, wind energy and fuel cell energy with battery backup to make best use of their operating characteristics and obtain better reliability than that could be obtained by single renewable energy based power supply. The proposed embedded controller is programmed for maintaining a constant voltage at PCC, maximum power point tracking for solar PV panel and WTG and power flow control by regulating the reference currents of the controller on instantaneous basis based on the power delivered by the sources and load demand. Instantaneous variation in reference currents of the controller enhances the controller response as it accommodates the effect of continuously varying solar insolation and wind speed in the power management. The power conditioner uses a battery bank with embedded controller based online SOC estimation and battery charging system to suitably sink or source the input power based on the load demand. The simulation results of the proposed power management system for a standalone solar/WTG/fuel cell fed hybrid power supply with real time solar radiation and wind velocity data collected from solar centre, KEC for a sporadically varying load demand is presented in this paper and the results are encouraging in reliability and stability perspective.

Performance Improvement of Air Conditioner Network System using Wireless Sensors Through System Performance Index and Dynamic Power Distribution Control (시스템 성능 지수 및 동적 전력분산 제어를 통한 무선센서를 이용한 에어컨 네트워크 시스템의 성능 개선)

  • Choi, Ho-seek;Kwon, Woo-hyen;Yoon, Byung-keun
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.1
    • /
    • pp.64-70
    • /
    • 2019
  • Wireless sensors have been developed in numerous ways for enhancing the convenience of installation, management and maintenance of sensors. Energy harvesting wireless sensors, which can collect energy from the external environment for permanent usage without the need of recharging and exchanging batteries, have been developed and employed used in Internet of Things and at various industrial sites. Energy harvesting wireless sensors are significantly affected by the sensor lifespan to sudden variation in the external environment. Furthermore, reduction in the sensor operating timespan can greatly affect the characteristics of the devices connected through a network. In this paper, a system performance index is proposed that can comprehensively evaluate the lifespan of a solar cell wireless sensor, determine the characteristics of devices connected to the associated network, and recommend dynamic power distribution control for improving the system performance index. Improvement in the system performance index was verified by applying the proposed dynamic power distribution control to an air conditioner network system using a solar cell wireless sensor. Obtained results corroborate that the dynamic power distribution control can extend the lifespan of the incorporated wireless sensor and reduce the air conditioner's power consumption.

Proposed measure for Smart Grid's Personal Information Security Issue (스마트 그리드 개인정보 보안이슈 방안 제시)

  • Choi, Heesik;Cho, Yanghyun
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.12 no.4
    • /
    • pp.41-49
    • /
    • 2016
  • Smart Grid is a next generation of new power growth electrical grid which provide high quality of electrical service by using Information Technologies to increase intelligence and performance. By using Smart Grid system, it can support energy management such as increase quality of electrical power, decrease energy and decrease emissions. However, Smart Grid uses information of energy consumption and when Smart Grid collects information, it will create private information. In this thesis, it will address issues of security private information which caused by Smart Grid for administrative measure and efficiency of Smart Grid in domestic. Also, cryptographic module algorithm, latest security solutions and strong wireless security policy for network environment such as wireless communication Iinternet are require for Smart Grid perform successfully and protect national power network equipment from cyber-attack and can stop leakage of user's personal information. Finally, it is urgent to prepare protection measures of National industrial facilities and power grid which can prepare for a cyber terrorism and penetration attacks and build emergency countermeasure management team for Smart Grid are require for safe Smart Grid environment.

Development of Network Analysis Applications for Korean Energy Management Systems (한국형 EMS 계통해석 프로그램 개발)

  • Cho, Y.S.;Yun, S.Y.;Lee, U.W.;Shin, C.H.;Lee, J.;Hur, S.I.;Kim, S.K.;Lee, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.258_259
    • /
    • 2009
  • This paper describes the development of robust processor for analyzing network state in Korean Energy Management System. The important function of topology processing is to convert the switching/device model into a bus/branch model by the status of switching devices. The state estimator also provides a consistent unified solution, not only for measurement of the observable system, but also for the unobservable system. The primary function of the online power flow is to provide a highly reliable and flexible power flow solution that can be used to solve a wide variety of power systems problems. The validity of the newly developed functions has been verified through comparative simulations with the existing EMS functions, which are currently in use in the Korean power system.

  • PDF

Efficient Authentication and Management System for PLC-based AMR (전력선통신기반 원격검침시스템을 위한 효율적인 기기인증 및 관리체계)

  • Ju, Seong-Ho;Choi, Moon-Seok;Lim, Yong-Hoon;Choi, Jong-Hyup
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.353-354
    • /
    • 2008
  • Security weakness in PLC network can be made up for by authentication and management scheme of PLC modules introduced in this paper. Each PLC module must pass the authentication procedure to work normally in PLC network as soon as being installed in the spot. Based on this scheme, all PLC devices are registered, certified, and managed automatically in central control center - AMR server, authentication server, NMS server, and DB server.

  • PDF