• 제목/요약/키워드: Power meter

검색결과 530건 처리시간 0.168초

랜덤 잡음을 이용한 원자로의 제어계 최적안전운전에 관한 연구 (1) (Optimation of Reactor Control System by using Random Noise)

  • 고병준;신재인
    • 대한전자공학회논문지
    • /
    • 제6권1호
    • /
    • pp.1-11
    • /
    • 1969
  • TRIGA MARK-II 원자로의 각출력에 대한 주파수스펙트럼을 측정하므로서 원자로의 전달함수의 계수율을 선정하였다. 랜덤한 파일잡음의 검출은 전전력에서 10-7A인 평행원부형 전리함을 이용하였다. 주파수스펙트럼은 동조형대역통과 여파기를 가지고 해석하여 원자로의 동특성과 그 피라미터를 구하고 전력측정을 하였다.

  • PDF

전력선 통신을 이용한 원격 전력분석 및 제어시스템에 관한 연구 (The study of the remort power analysis and control system using power line communication)

  • 최원호;이후찬;박종연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.211-213
    • /
    • 2005
  • RPA(Remelt Power Analysis)and RC(Remote Control) System have been researched from former several decade for a various power rate system a efficent power service and rising of personal expenses, etc. But the existing RPA and RC System have disadventage which are complex and high cost to install an individual communication network of electricity company This paper proposed a new type of RPA and RC System using PLC with Internet. and made components for proposal system so we made the PLC modem, the digital watt-hour meter with a build in PLC modem and the softwere on server computer for establishing the proposal system. The bit rate of the proposed system is about 4800bps.

  • PDF

휴대용 극저주파 전장측정기 개발 (Development of a Portable ELF Electric Field Meter)

  • 길경석;송재용;김일권
    • 센서학회지
    • /
    • 제9권2호
    • /
    • pp.120-126
    • /
    • 2000
  • 본 논문은 평판형 센서, 아날로그 증폭기, 이득 조성 가능한 A/D 변환기 및 표시장치로 구성되는 휴대용 전장 측정기에 대하여 기술하였다. 극저주파 대역의 시변전장 검출을 위한 센서의 원리를 설명하고, 원통형 가드전극계와 평행평판 전극계의 교정장치를 제안하였다. 교정실험 결과로부터 전장측정기의 주파수 대역과 감도는 각각 $17[Hz]{\sim}7[kHz]$, 4.45[mV/V/m]이었다. 또한 측정 가능한 최대 전장의 세기는 10[kV/m]이며, 측정 결과는 액정화면에 숫자로 표시된다. 본 전장측정기는 전력선, 컴퓨터 및 헤어드라이기나 히터와 같은 가전기기 등에서 방사되는 전장의 세기 측정에 광범위하게 적용될 것이다.

  • PDF

250 m 급 Bi-2223/Ag 고온 초전도선재 제조 (Fabrication of 250 m class Bi-2223/Ag HTS Tapes)

  • 하홍수;오상수;하동우;장현만;김상철;송규정;박찬;권영길;류강식
    • Progress in Superconductivity
    • /
    • 제3권1호
    • /
    • pp.130-133
    • /
    • 2001
  • A multifilamentary Bi-2223 HTS tape for superconducting power applications was studied through the fabrication of 250-meter long tapes by the PIT(powder in tube) process. To fabricate continuous long wire, a drawing machine, a two-drum bull block and a rolled tape winding machine were developed. Especially, 250-meter long tapes were heat treated in the shape of pancake coil to reduce the heat affect zone and to achieve the high critical current. Engineering critical current density was improved through both the enhancements of critical current density by control of thermal process and the increase of filling factor by using thin Ag alloy sheath tubes less than 1.5 mm in thickness. We have made successfully 250-meter long 37 filamentary tapes with high filling factor up to 31 % employing the modified drawing and rolling technique. The critical current of 250-meter long tapes with pancake coil type was measured by transport method at self-field up to 250 gauss of center field. The measured values, based on the transport critical current at self-field, $I_{c}$ -B characteristics and magnetic field analysis, are 34 A of I$_{c}$ and 4.0 $kA/\textrm{cm}^2$ of $J_{e}$ at 250 m, 77 K, and 0 T. We also have achieved the 56 A of I$_{c}$ and 7.0 $0 kA/\textrm{cm}^2$ of$ J_{e}$ in short tapes at 77K, self-field, and 1$mutextrm{V}$/cm.

  • PDF

소규모 재생발전사업자의 중개시장참여 촉진요인 분석 (Analysis of Factors Driving the Participation of Small Scale Renewable Power Providers in the Power Brokerage Market)

  • 이드미트리;배정환
    • 신재생에너지
    • /
    • 제18권3호
    • /
    • pp.32-42
    • /
    • 2022
  • Rapid spread of intermittent renewable energy has amplified the instability and uncertainty of power systems. The Korea Power Exchange (KPX) promoted efficient management by opening the power brokerage market in 2019. By combining small-scale intermittent renewable energy with a flexible facility through the power brokerage market, the KPX aims to develop a virtual power plant system that will allow the conversion of existing intermittent renewable energy into collective power plants. However, the participation rate of renewable power owners in the power brokerage market is relatively low because other markets such as the small solar power contract market or the Korea Electric Power Corporation power purchase agreement are more profitable. In this study, we used a choice experiment to determine the attributes affecting the participation rate in the power brokerage market for 113 renewable power owners and estimate the value of the power brokerage market. According to the estimation results, a low smart meter installation cost, low profit variations, long contract periods, and few clearances increased the probability of participation. Moreover, the average value of the power brokerage market was estimated to be 2.63 million KRW per power owner.

Adaptive algorithm for optimal real-time pricing in cognitive radio enabled smart grid network

  • Das, Deepa;Rout, Deepak Kumar
    • ETRI Journal
    • /
    • 제42권4호
    • /
    • pp.585-595
    • /
    • 2020
  • Integration of multiple communication technologies in a smart grid (SG) enables employing cognitive radio (CR) technology for improving reliability and security with low latency by adaptively and effectively allocating spectral resources. The versatile features of the CR enable the smart meter to select either the unlicensed or the licensed band for transmitting data to the utility company, thus reducing communication outage. Demand response management is regarded as the control unit of the SG that balances the load by regulating the real-time price that benefits both the utility company and consumers. In this study, joint allocation of the transmission power to the smart meter and consumer's demand is formulated as a two stage multi-armed bandit game in which the players select their optimal strategies noncooperatively without having any prior information about the media. Furthermore, based on historical rewards of the player, a real-time pricing adaptation method is proposed. The latter is validated through numerical results.

다공성 표면 화염의 복사열효율측정에 관한 논의 (A Discussion on the Radiation Efficiency Measurement of Porous Surface Flames)

  • 정황희;심근선;이기만
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2014년도 제49회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.157-159
    • /
    • 2014
  • This article describes an investigation of basic combustion characteristics of radiant burner with various firing rate and equivalence ratios in porous metal. As a main experimental condition, firing rates and equivalence ratios each were adjusted from 204 to $408kW/m^2$ and 0.6 to 1.3. The purpose of this study is to investigate radiation efficiency using two experiment methods. The first way is to calculate the radiation efficiency by measuring the temperature of the burner surface, and the second is to compute the radiation efficiency by measuring the radiation intensity of the burner surface with a radio meter. The value of the radiation efficiency did not exactly match in the two cases. But we figured out that in accordance with increasing heat power, radiation efficiency was decreased. And additional complementary experiment on the relationship between these values is needed.

  • PDF

전력량계 무정전 교체장치 개발에 관한 연구 (Development of Watt-Hour Meter Exchange Equipment without Outage)

  • 정태훈;조성민;신희상;이희태;김재철
    • 조명전기설비학회논문지
    • /
    • 제23권8호
    • /
    • pp.99-103
    • /
    • 2009
  • 본 논문에서는 부하설비의 정전 시간을 최소화하기 위한 전력량계 무정전 교체 장치를 고안하여 개발하였다. 개발된 교체 장치는 전력량계 교체 시 정전을 피하기 위해 시행되고 있는 단순 우회회로 결선방법, UPS 사용법 등, 다른 방법들에 비해 간편하여 효율성을 증대하였다. 그리고 교체 작업동안 안전성을 확보하기 위하여 보호 요소들을 구성함으로써 신뢰성 또한 증대하였다. 본 장치의 적용으로 고객에게 정전 시간을 단축하여 신뢰성 있는 전력공급을 보장할 수 있게 되었다.

위험전압 측정기의 설계 및 제작

  • 장운용;박대원;한주섭;길경석
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 춘계학술대회 논문집
    • /
    • pp.25-25
    • /
    • 2010
  • This paper describes the design and fabrication of a Risk Voltage Meter (RVM) which can analyze the step and touch voltages in grounding systems. The meter consists of a sine-wave power source which generates up to 300 [$V_{rms}$] in ranges of 45 [Hz]~1 [kHz], a 8 Ch. data acquisition module, and a personal computer. Also, a noise elimination method by a digital band-pass filter during measurement is proposed.

  • PDF

Implematation of AMR system using Power ine Communication

  • Park, Byoung-Seok;Hyun, Duck-Hwa;Jang, Mun-Jeong;Lim, Young-Hoon;Cho, Sung-U
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.119.4-119
    • /
    • 2001
  • It is the advantage of PLC that digitalization and networking of existing facility can be organized at low price because there is no need further construction of communication line considering that home appliance, information device and various kind of control devices are digitalized at low price. Moreover, AMR(Automatic Meter Reading) is very attractive to utility company because not only does it reduce the cost of reading meter, but also it can control and monitor the demand for energy. So, it can solve the consumers problem best and easily. It also can be easily realized that the utilities can expand there areas to values-added service through existing network. The performance of the PLC modem which is being developed now is not moven enough and much more test for outdoor modem is needed especially. Therefore, we, KEPRI, concentrate our efforts on configuring AMR system for test and investigation of the actual performance of various kinds ...

  • PDF