• Title/Summary/Keyword: Power meter

Search Result 527, Processing Time 0.029 seconds

COMPARISON OF LINEAR POLYMERIZATION SHRINKAGE IN COMPOSITES AND COMPOMER POLYMERIZED BY PLASMA ARC OR CONVENTIONAL VISIBLE LIGHT CURING (리노미터를 이용한 할로겐 가시광선 광조사기와 플라즈마 아크 광조사기의 복합레진 및 컴포머의 광중합 양상 비교)

  • Lee, Jae-Ik;Park, Sung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.5
    • /
    • pp.488-492
    • /
    • 2002
  • The purpose of this study was to evaluate the effectiveness of plasma arc curing (PAC) unit for composite and compomer curing. To compare its effectiveness with conventional quartz tungsten halogen (QTH) light curing unit, the polymerization shrinkage rates and amounts of three composites (Z100, Z250, Synergy Duo Shade) and one compomer, that had been light cured by PAC unit or QTH unit, was compared using a custome made linometer. The measurement of polymerization shrinkage was peformed after polymerization with either QTH unit or PAC unit. In case of curing with the PAC unit, the composite was light cured with Apollo 95E for 6s, the power density of which was recorded as 1350 mW/$\textrm{cm}^2$ by Coltolux Light Meter. For light curing with QTH unit, the composite was light cured for 30s with the XL2500, the power density of which was recorded as 800 mW/$\textrm{cm}^2$ by Coltolux Light Meter. The amount of linear polymerization shrinkage was recorded in the computer every 0.5s for 60s. Ten measurements were made for each material. The amount of linear polymerization shrinkage for each material in 10s and 60s which were cured with PAC or QTH unit were compared with t test. The amount of polymerization shrinkage in the tested materials were compared with 1way ANOVA with Duncan's multiple range test. As for the amounts of polymerization shrinkage in 60s, there was no difference between PAC unit and QTH unit in Z250 and Synergy Duo Shade. In Z100 and Dyract AP, it was lower when it was cured with PAC unit than when it was cured with QTH unit (p<0.05). As for the amounts of polymerization shrinkage in 10s, there was no difference between PAC unit and QTH unit in Z100 and Dyract AP. The amounts of polymerization shrinkage was significantly higher when it was cured with PAC unit in Z250 and Synergy Duo Shade (p<0.05). The amounts of polymerization shrinkage in the tested materials when they were cured with QTH unit were Z250 (6.6um) < Z100 (9.3um), Dyract AP (9.7um) < Synergy Duo Shade (11.2um) (p<0.05). The amount of polymerization shrinkage when the materials were cured with PAC unit were Dyract AP (5.6um) < Z100 (8.1um), Z250(7.0um) < Synergy Duo Shade (11.2um) (p<0.05).

The Valuation of HSA Business Using Broadband over Power Line (전력선통신망을 이용한 HSA사업의 경제적 타당성 분석)

  • Lyoo, Tae-Ho;Kim, Chang-Seob
    • Journal of Energy Engineering
    • /
    • v.16 no.4
    • /
    • pp.202-214
    • /
    • 2007
  • The concept of HSA (Home Service Aggregator) is derived from performing the energy IT business efficiently as well as successfully launcing a new service based on BPL (Broadband over Power Line). The HSA business using a BPL can extend the field of energy industry and an give a chance to create a new demand by consumer-oriented services. This study focuses on the exact evaluation of HSA business using BPL, and reasonable trusty evaluation should be the first step to launch the HSA business. In this study, the categories of cost are comprised of equipment (mainly RSM and MGW) cost, instalation cost, and maintenance cost. AMR (Automatic Meter Reading), internet integration billing service, integration charging service, internet service, sorority service, and electricity safety are listed for benefit. In this study, the ROI of HSA business is 0.9594, which is less than 1. However, that value does not consider the electricity safety benefit which is classified as a social benefit. Therefore, the value can be above 1 if it includes social and private benefits.

Design of Speed-Variable Driving System and Tester for Electric Forklift Truck (전동지게차용 변속 구동부 및 시험기 설계)

  • Shim, J.H.;Kang, H.K.;Ham, S.H.;Oh, S.H.
    • Journal of Power System Engineering
    • /
    • v.12 no.3
    • /
    • pp.38-43
    • /
    • 2008
  • The usage of electric forklift truck is gradually increasing due to the convenience at conveying and arranging the materials in the industrial field. In this study, the author designed and suggested the optimum driving system and load tester which both of them are the most important part of the forklift truck. The planetary gear is chose to driving system because it makes big power even though the motor size is small. The gear teeth of planetary gear were designed and the designed planetary gear was tested considering the yield strength and the abrasion of gear teeth. The B-Type electric brake which consists of multiple plates and operates with non-magnetic type was connected with a single shaft in the driving system. So, it can be applied at the sudden braking situation which has the torque increment. And it has the compact size and excellent durability Load tester can give the various levels of load to the planetary gear of driving system in the electric forklift truck and it can also measure the levels of the load which were applied. Therefore, we can measure the noise, torque and perform the durability, vibration tests using load tester. It will be economical because many kinds of test can be performed using reasonable priced load tester The driving system of electric forklift truck which has sufficient competitive can be manufactured using our designed planetary gear reducer with reasonable price. The designed load tester can use for checking the performance of other reducers, as well.

  • PDF

Radiological Environment Investigation of Radioactive Waste Disposal Facility (방사성폐기물 처분시설 주변의 방사선환경조사)

  • Baek, Jeong-Seok;Jeong, Yeui-Young;Ahn, Sang-Bok;Kim, Wan
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.4
    • /
    • pp.387-398
    • /
    • 2008
  • To obtain base-line data in the low- and intermediate-level radioactive waste disposal facility, radiological environment investigation is required at least two years prior to the facility operation near the disposal facility. The investigation has been performed since January 2007 for the Wolsong LILW disposal center. In this paper, investigation procedure and detailed information obtained for six months in 2008 are described. Based on the current results, future investigation planning is also discussed for the radiological environment management of the disposal facility.

  • PDF

The Study of Verification Bi-Digital O-Ring Test by gauges (계측기(計測器)를 이용한 O-Ring Test법(法)의 검증(檢證)에 관(關)한 연구(硏究))

  • Kim, Jeong-Ryeol;Kim, Dal-Rae
    • The Journal of Korean Medicine
    • /
    • v.16 no.2 s.30
    • /
    • pp.225-247
    • /
    • 1995
  • Using Bi-Digital O-Ring Test which was developed by Ohmura Toshiaki, constiution classification by the vegetables' was Measured by various muscle power measurement meters and the results are as follow: 1. Pinch Gauge (Model:pc5030HPG, Japan) is the gauge to measure finger power between the thumb and the second finger, Grip Strength Dynamometer (Model: T.K.K. 5101, Japan) is to measure the hand power (hand dynamometer), Back Strength Dynamometer (Model: T.K.K. 5102, Japan) is to measure back muscle strength, Vertical jump Meter (Model: T.K.K. 5106, Japan) is to measure the height of jump. The above gauges were and its result found that the radish, potato, carrot and cucumber can influence to muscle strength was not true. 2. When the physical constitution is distinguished by the O-Ring Test method, Taeyangin's rate appeared as average 21% although it was insisted that there will be only 0.03-0.1%. This means that the physical constitution but it appears accidently according to the examinee's emotion about the material such as vegetable etc. as favor or unfavor. 3. It was found that the result of O-Ring Test is the same at any time and at any place was not true. there is no reemergence character. 4. The import of O-Ring Test mehtod to the physical discrimination disregarded that the mental factor influences absolutely to the physical heath in the ideological physi cal constitution medical science. 5. 'O-Ring Test method is a objective judgement method.' is wrong judgement. As you see on the above result, Bi-Digital O-Ring Test set the changeable voluntary muscle as the standard of the judgument, that was first mistake logically, second in spite of leass influence of mental influence by the examiner and examinee than the vegetable discrimination influence, the test disregarded the influence. Third, only grasp of some material on hand can influence to the voluntary muscle was a wrong theory disregarding the physiology. Finally the misunderstaning his subjective view as an objective view in spite of examiner and examinee's strong influence. Therefore such kind of physical descrimination method must be sublated.

  • PDF

A Design of an AMI System Based on an Extended Home Network for the Smart Grid (스마트 그리드를 위한 확장 홈 네트워크 기반의 AMI 시스템 설계)

  • Hwang, Yu-Jin;Lee, Kwang-Hui
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.49 no.7
    • /
    • pp.56-64
    • /
    • 2012
  • A smart grid is the next generation power grid which combines the existing power grid with information technology, so an energy efficient power grid can be provided. In this paper, in order to build an efficient smart grid an AMI system, which gears with the existing home network and provides an user friendly management function, is proposed. The proposed AMI system, which is based on an extended home network, consists of various functional units; smart meters, communication modules, home gateway, security modules, meter data management modules (MDMM), electric power application modules and so on. The proposed home network system, which can reduce electric power consumption and transmit data more effectively, is designed by using IEEE 802.15.4. The extended home gateway can exchange energy consumption information with the outside management system via web services. The proposed AMI system is designed to enable two-way communication between the home gateway and MDMM via the Internet. The AES(Advanced Encryption Standard) algorithm, which is a symmetric block cipher algorithm, is used to ensure secure information exchange. Even though the results in this study could be limited to our experimental environment, the result of the simulation test shows that the proposed system reduces electric power consumption by 4~42% on average compared to the case of using no control.

RCCA End-Tip Examination by ECT (원자로 제어봉 End-Tip 원주방향균열 와전류검사)

  • Lee, H.J.;Nam, M.W.;Jung, G.J.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.6
    • /
    • pp.455-463
    • /
    • 1998
  • RCCA(rod cluster control assembly) End-Tip suffers from neutron irradiation and constant vibration due to high-speed internal flow of primary coolant during plant operation. Such operating conditions cause the RCCA end-tip crackings around tile circumferential weldment of the end-tip, and in some cases, the defective end-tips were completly broken loose. However, no reliable inspection techniques for end-tip crackings were developed in the past, although some techniques exist for inspecting RCCA control rod wears. Therefore, NDE group at KEPRI has developed an ECT technique for the detection and the sizing of the end-tip crackings. The technique uses a specially designed surface-riding probe that can detect size of circumferential crackings with an accuracy of ${\pm}5.31%$ RMS error. This paper describes the ECT instrumentation including the ECT probes, calibration bars, as well as technical approaches.

  • PDF

Experimental study on characteristics of evaporation heat transfer of $CO_2$ in horizontal micro-channel tube (수평 다채널관 내 이산화탄소의 증발 열전달 특성에 관한 실험적 연구)

  • Lee, Sang-Jae;Kim, Dae-Hoon;Choi, Jun-Young;Lee, Jae-Heon;Kwon, Young-Chul
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2200-2205
    • /
    • 2007
  • In order to investigate the variation on a heat transfer coefficient during evaporation of $CO_2$, basic experiment on the evaporation heat transfer characteristics in a horizontal micro-channel tube was performed. Hydraulic diameters of micro-channels were 0.68 and 1.46 mm. The experiment apparatus consisted of a test section, a DC power supply, a heater, a chiller, a mass flow meter, a pump and a measurement system. Experiments were conducted for various mass fluxes of 300 to 800 kg/$m^2s$, heat fluxes of 10 to 40 kW/$m^2$ and saturation temperatures of -5 to 5$^{\circ}C$. With the increase heat flux, the evaporation heat transfer coefficient increased. And the significantly change of the heat transfer coefficient was observed at any heat flux and mass flux. As the saturation temperature increased and the hydraulic diameter decreased, the heat transfer coefficient increased.

  • PDF

Volume Resistivity, Specific Heat and Thermal Conductivity Measurement of Semiconducting Materials for 154[kV] (154[kV]용 반도전층 재료의 최적저항, 비열 및 열전도 측정)

  • Lee, Kvoung-Yong;Yang, Jong-Seok;Choi, Yong-Sung;Park, Dae-Hee
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.11
    • /
    • pp.477-482
    • /
    • 2005
  • We have investigated volume resistivity and thermal properties showed by changing the content of carbon black which is the component parts of semiconducting shield in underground power transmission cable. Specimens were made of sheet form with the nine of specimens for measurement. Volume resistivity of specimens was measured by volume resistivity meter after 10 minutes in the preheated oven of both 25$\pm$1[$^{\circ}C$] and 90$\pm$1[$^{\circ}C$]. And specific heat (Cp) and thermal conductivity were measured by Nano Flash Diffusivity and DSC (Differential Scanning Calorimetry). The measurement temperature ranges of specific heat using the BSC was from 20[$^{\circ}C$] to 60[$^{\circ}C$], and the heating rate was 1[$^{\circ}C$/min]. And the measurement temperatures of thermal conductivity using Nano Flash Diffusivity were both 25[$^{\circ}C$] and 55[$^{\circ}C$]. Volume resistivity was high according to an increment of the content of carbon black from these experimental results. And specific heat was decreased, while thermal conductivity was increased by an increment of the content of carbon black. And both specific heat and thermal conductivity were increased by heating rate because volume of materials was expanded according to rise in temperature.

Development of Monitering System for Remote Power Management Service (원격 전력관리 서비스를 위한 모니터링 시스템 개발)

  • Park, Ji-Saung;Jeon, Min-Ho;Lee, Myung-Eui
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.601-604
    • /
    • 2012
  • Recently, there have been many attempts to monitor the equipment's condition or the input devices in sensors remotely by using cable and wireless communications. Also, the research and development on this matter has been actively carried on. In this paper, we developed the monitoring system which will eliminate the errors of manual reading by humans and therefore will secure reliability between tenants and the building management office. Through the system, the private telecommunication network can be connected between the building management office and the households. This enables the control office to remotely read the electric meter and exact energy consumption of each household even when the tenants are absent.

  • PDF