• 제목/요약/키워드: Power management and control system

검색결과 805건 처리시간 0.03초

Design of a Cooperative Voltage Control System Between EMS (VMS) and DMS

  • Shin, Jeonghoon;Lee, Jaegul;Nam, Suchul;Song, Jiyoung;Oh, Seungchan
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제6권3호
    • /
    • pp.279-284
    • /
    • 2020
  • This paper presents the conceptual design of a cooperative control with Energy Management System (EMS) and Distribution Management System (DMS). This control enables insufficient reactive power reserve in a power transmission system to be supplemented by surplus reactive power in a power distribution system on the basis of the amount of the needed reactive power reserve calculated by the EMS. This can be achieved, because increased numbers of microgrids with distributed energy resources will be installed in the distribution system. Furthermore, the DMS with smart control strategy by using surplus reactive power in the distribution system of the area has been gradually installed in the system as well. Therefore, a kind of hierarchical voltage control and cooperative control scheme could be considered for the effective use of energy resources. A quantitative index to evaluate the current reactive power reserve of the transmission system is also required. In the paper, the algorithm for the whole cooperative control system, including Area-Q Indicator (AQI) as the index for the current reactive power reserve of a voltage control area, is devised and presented. Finally, the performance of the proposed system is proven by several simulation studies.

독립형 태양광 발전을 이용한 효율적인 하이브리드 LED 가로등 조명관리 시스템 설계 (An Efficient Hybrid LED Street Lighting Management System Design using Standalone Solar Photovoltaic)

  • 홍성일;인치호
    • 제어로봇시스템학회논문지
    • /
    • 제20권9호
    • /
    • pp.984-993
    • /
    • 2014
  • In this paper, we propose a design for an efficient hybrid LED street lighting management system using standalone solar photovoltaic. The proposed efficient hybrid LED street lighting management system was composed of hybrid power conditioning system, gateways, LED street lights and a monitoring server. The hybrid power conditioning system was designed to charge produced power by solar photovoltaic panels in day time, and supply power to the LED street lights in night time. If there is insufficient power, the system was designed to operate using firm power, because the system utilizes photovoltaic power. A system control algorithm allied to the lighting management system, and experimented by being configured to the functions that are able to perform real-time monitoring and remote control through the lighting management system even when absent. In the result of the efficiency analysis of the hybrid lighting management system proposed in this paper, we were able to increase the energy efficiency compared to existing lighting control systems by reducing power consumption and electricity costs.

수요 제어에 의한 전력 시스템의 효율 운전 (Effective Management of Power System by Demand Control)

  • 최진원
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.77-79
    • /
    • 2003
  • For the management of maximum demand power, power control system that is consist of CCMS(Central Control and Management System) and MCCS(Minimum Cost Control and management Software) is proposed. MCCS has the basic functions of the set of target power and the enrollment of load control logic. And also MCCS give the simulation of Power rate that help more effective Demand Control.

  • PDF

Power Management of Open Winding PM Synchronous Generator for Unbalanced Voltage Conditions

  • EL-Bardawil, Ashraf;Moussa, Mona Fouad
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2192-2201
    • /
    • 2016
  • Wind energy is currently the fastest-growing electricity source worldwide. The cost efficiency of wind generators must be high because these generators have to compete with other energy sources. In this paper, a system that utilizes an open-winding permanent-magnet synchronous generator is studied for wind-energy generation. The proposed system controls generated power through an auxiliary voltage source inverter. The VA rating of the auxiliary inverter is only a fraction of the system-rated power. An adjusted control system, which consists of two main parts, is implemented to control the generator power and the grid-side converter. This paper introduces a study on the effect of unbalanced voltages for the wind-generation system. The proposed system is designed and simulated using MATLAB/Simulink software. Theoretical and experimental results verify the validity of the proposed system to achieve the power management requirements for balanced and unbalanced voltage conditions of the grid.

A Multiagent-Based Hybrid Power Control and Management of Distributed Power Sources

  • Yoon, Gi-Gab;Hong, Won-Pyo;Lee, Ki-Hong
    • 조명전기설비학회논문지
    • /
    • 제25권8호
    • /
    • pp.70-81
    • /
    • 2011
  • In this paper, a multi-agent control system for DC-coupled photovoltaic (PV), fuel cell (FC), ultracapacitor(UC) and battery hybrid power system is studied for commercial buildings & apartment buildings microgrid. In this proposed system, the PV system provides electric energy to the electrolyzer to produce hydrogen for future use and transfer to the load side, if possible. Whenever the PV system cannot completely meet load demands, the FC system provides power to meet the remaining load. A multi-agent system based-power management and control algorithm is proposed for the hybrid power system by taking into account the characteristics of each power source. The main works of this paper are hybridization of alternate energy sources with FC systems using long and short storage strategies to build the multi-agent control system with pragmatic design, and a dynamic model proposed for a PV/FC/UC/battery bank hybrid power generation system. A dynamic simulation model for the hybrid power system has been developed using Matlab/Simulink, SimPowerSystems and Stateflow. Simulation results are also presented to demonstrate the effectiveness of the proposed multi-agent control and management system for building microgrid.

Effective modular assembly line control system

  • Eom, Eu-Gan;Kim, Dong-Shin;Ahn, In-Seok;Park, Jong-Oh;Kim, Young-Tae;Kim, Sung-Kwon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1993년도 한국자동제어학술회의논문집(국제학술편); Seoul National University, Seoul; 20-22 Oct. 1993
    • /
    • pp.293-297
    • /
    • 1993
  • In this paper, a new design method for Assembly Line Control System(ALCS) is presented. This system consists of five independent modules having their own specific functions such as production management, facility management material management, quality management, and remote control. To implement the ALCS, we propose design of the common data management module(CDMM). This module has the roles of integrating the above five modules and of communicating the common data between them. Using this method, we realize an information management method in the view of CIM. In addition, we standardize the inter-communication of common data between machines having different interface protocols.

  • PDF

효율적인 배전관리를 위한 컴퓨터 응용연구 (A study on the computer application for efficient management of the power distribution system)

  • 이병철;서영노;정진현;고윤석;김호용
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1993년도 한국자동제어학술회의논문집(국내학술편); Seoul National University, Seoul; 20-22 Oct. 1993
    • /
    • pp.975-980
    • /
    • 1993
  • In accordance with increase, if electronic power demanded, more efficient supervisory control of distribution system will be required. This study contains development of MMI(man-machine-interface) system with GUI(graphic-user-interface), for the automatic power distribution system. The main function of MMI system is to edit network of power distribution and to management of data base for network. The GUI function of MMI system enables more efficient management of power distribution system.

  • PDF

개별 부하 시스템의 에너지 절감을 포함한 선박 전력 에너지 관리 시스템 개발 (Development of Power Energy Management System for Ships including Energy Saving of Separated Load Systems)

  • 강영민;오진석
    • 한국정보통신학회논문지
    • /
    • 제22권1호
    • /
    • pp.131-139
    • /
    • 2018
  • 최근 4차 혁명과 연계하여 많은 선박 분야의 연구들이 수행되고 있으며, 그 중 하나로 에너지 관리시스템 (EMS: Energy Management System)이 관심을 받고 있다. 에너지 관리시스템은 선박의 에너지를 관리하기 위한 시스템을 통칭하며, 다양한 시스템을 포함한다. 본 논문에서는 선박에서의 에너지 절감 분야를 분석하고, 기관실에서 에너지 절감이 가능한 개별 부하 제어 시스템을 포함한 선박 전력 에너지 관리 시스템을 제안한다. 제안하는 EMS는 PCS (Pump Control System), ERFCS (Engine Room Fan Control System), LCS (Load Control System), HVACS (Heating, Ventilation, Air conditioning Control System)의 개별 부하 제어 시스템을 포함한다. 1차적으로, 제안하는 EMS는 기관실의 개별적인 부하 시스템에서 에너지를 절감한다. 2차적으로는 통합 모니터링 및 제어 시스템을 통해 발전 시스템과 전력 부하 시스템을 적절히 제어하여 에너지를 절감한다.

안전한 전력 제어시스템 설계를 위한 위험관리 프레임워크 제안 (A Proposal of Risk Management Framework for Design as a Secure Power Control System)

  • 박준용;신수민;송경영
    • 정보보호학회논문지
    • /
    • 제26권2호
    • /
    • pp.425-433
    • /
    • 2016
  • 지능형 전력망에서 전력 서비스의 효율성 및 상호운용성 확보를 위한 지능형 전력망과 외부망 연계로 인해 전력 제어시스템을 대상으로 한 공격 위협이 증가하고 사이버테러의 주요 목표가 되고 있어 이에 따른 안전한 시스템 설계가 중요한 화두로 등장하고 있다. 일반적으로 SSDLC를 적용하여 설계 단계에서부터 위험에 대한 관리를 하고 있으나 전력 제어 시스템의 특성을 고려한 사항은 부족한 실정이다. 따라서, 전력 제어시스템의 진단 모형 및 평가 프로세스 설계가 가능하고 정보보안 방향성 및 관련 지표를 제공하기 위해, IEC 62351 TC 57에서 제시한 운영보안통제 사항 및 표준 아키텍처에 전사적 위험관리 프레임워크를 응용한 전력 제어시스템 위험관리 프레임워크를 제안하고자 한다.

Variable Priority Number Control of SPMS for Leisure Ship

  • Oh, Jin-Seok;Park, Do-Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권1호
    • /
    • pp.141-148
    • /
    • 2012
  • The power system of leisure ship has a character of stand-alone type, so it continuously checks the usable power. Especially, the leisure ship using renewable energy needs to adjust the power consumption of loads according to the usable power. Also, the important loads of leisure ship are different by operation mode. However, current power management system doesnot consider such character. This paper studied load management system of the SPMS(Smart Power Management System) and composed using the smart plug. The SPMS controls the loads depending on a user's pattern and character through variable priority number control. This control algorithm was verified through simulation of assumed user and situation using LabVIEW.