• 제목/요약/키워드: Power line

검색결과 6,051건 처리시간 0.034초

전력선 통신채널의 시뮬레이터 개발 (Simulator Development for Power Line Communication Channel)

  • 박종연;정동열
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제49권9호
    • /
    • pp.546-553
    • /
    • 2000
  • W e have developed a power line simulator which is one of the basic tools for the research of the power line communication and its control system. In the developed simulators, we have considered the transfer function of the power line, noises and signal attenuation characteristics. Simulator was made using the matlab tool program. We made the power line modem using the FSK chip(ST7537) and experimentalized to show the efficiency grade of simulator. We have expected that the developed simulators are very useful in the area for the power line communication research and the control system design.

  • PDF

전기철도 전원계통에서의 화재 사고사례 분석 (Analysis of Fire Accidents on Power Line for DC Electric Traction Vehicles)

  • 송재용;조영진;김진표;박남규;길경석
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.241-247
    • /
    • 2008
  • This paper describes a cause of fire accidents on power system for DC electric traction vehicles. We investigated fire scene of power line for DC electric traction vehicles. From analysis results, the cause of fire on power line turned out line to ground fault between a feeder of electric power services(pantagraph) and DC electric traction vehicle roof. Fire accidents of DC electric traction vehicles be assumed that electric sparks had been produced between the pantagraph and the power line conductor by repetitively making contact and separation, maybe if some material like branches get in between connecting rod it make progress line to ground fault. ZnO arresters are widely used to protect DC electric traction vehicles against overvoltages caused by lightning or switching surges. However, the arresters are deteriorated by commercial frequency overvoltages and/or lightning one. Deteriorated arresters could lead power failures, such as line to ground fault by a thermal runaway resulting from the increases in leakage current even in a nominal power system voltage. The power failures, such as line to ground fault would be causative of the fire accidents.

  • PDF

가공송전선로의 AAR 적용 시 Risk Tolerance 분석을 이용한 계절별 최대 허용전류 산정 및 적용에 관한 연구 (Study on the Estimation of Seasonal Ambient Current for the Application of Ambient Adjusted Line Rating(AAR) in Overhead Transmission Lines Using Risk Tolerance(RT) Method)

  • 이재걸;배영재;송지영;신정훈;김용학;김태균;윤용범
    • 전기학회논문지
    • /
    • 제66권1호
    • /
    • pp.7-15
    • /
    • 2017
  • Ambient Adjusted line Rating(AAR) method for overhead transmission lines considering Risk Tolerance(RT) was proposed in this paper. AAR is suitable for system operators to plan their operation strategy and maintenance schedule because this can be designed as a seasonal line rating. Several candidate transmission lines are chosen to apply the proposed method in the paper. As a result, it is shown that system reliability was significantly enhanced through maximizing transfer capability, solving the system constraints.

고속 전력선통신의 현장성능 분석 (Field Testing of High-Speed Power Line Communications)

  • 김상조;이병구;김근영;김석호
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 한국정보통신설비학회 2009년도 정보통신설비 학술대회
    • /
    • pp.227-230
    • /
    • 2009
  • In this paper, the results of field testing of high-speed power line in-home networking in Korea are reported. When multiple networks share a common channel, they can interfere destructively and reduce system capacity. This is major problem in-home power line communications, especially in MDU deployments. The effects of neighboring network interference in power line communications are reported.

  • PDF

끝이 단락된 결합선로를 이용한 전력 분배기의 초소형화 (A New Reduced-Sized Lumped Distributed Power Divider Using The Shorted Coupled-line Pair)

  • 강인호;최재교
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2003년도 종합학술발표회 논문집 Vol.13 No.1
    • /
    • pp.283-287
    • /
    • 2003
  • A new method to miniaturize ${\lambda}/4$ transmission line of power divider is proposed. The method utilizes simple combination of the shorted coupled-line pair instead of the transmission line with very high impedance and shunt lumped capacitors. The length of ${\lambda}/4$ transmission line of power divider is about 16% over the conventional power divider at 1 GHz.

  • PDF

입력전원 센서리스 능동형 전력필터의 구현 (Implementation of a Line-voltage Sensorless Active Power Filter)

  • 정강률
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.189-191
    • /
    • 2005
  • This paper proposes an implementation of a line- voltage sensorless three-phase active power filter. The line synchronization for an active power filter does not require any additional hardware. It can be properly operated under various line-voltage variation. Current compensation is done in the time domain allowing fast time response. All control functions are implemented in software using a single-chip microcontroller, thus simplifying the control circuit. It is shown via experimental results that the proposed controller gives good performance for the line-voltage sensorless active power filter.

  • PDF

전력선 통신을 이용한 plant 감시 제어 시스템 (Spread Spectrum Method based Power Line Communication for Plant Monitoring and Control System)

  • 서민상;성석경;안병규
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.211-215
    • /
    • 1997
  • Localized communication networks for office automation, security monitoring, environmental management of buildings, computer communications, and other applications enjoy every increasing demand. This paper proposes a direct sequence spread spectrum communication system for use in power line data transmission. Advantages of power distribution circuits include reasonably universal coverage and easy access vis a standard wall plug. Disadvantages include limited communication bandwidth, relatively high noise levels, and varying levels of impedance, noise, and attenuation. Spread spectrum signalling provides immunity to narrow-band signal impairments and multiplexing capability. Our prototype power line communication module supports completely physical and data link layers based on the international standard ISO 10368 for reliable high-speed power line communication system. Moreover it provides useful functions to compose a plant monitoring and control system. All the circuits of the communication module are included in one compact circuit. Thus a functional communication system for the power line plant monitoring and control is implemented.

  • PDF

신재생에너지 예측을 위한 송전선로의 계량 데이터 계산 방법 (Calculation Method of Dedicated Transmission Line's Meteological Data to Forecast Renewable Energy)

  • 백자현;김현진;최순호;박상호
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.55-59
    • /
    • 2022
  • This paper introduce Renewable Energy forecasting technology, which is a part of renewable management system. Then, calculation method of dedicated transmission line's meteorological data to forecast renewable energy is suggested. As the case of dedicated transmission line, there is only power output data combined the number of renewable plants' output that acquired from circuit breakers. So it is need to calculate meteorological data for dedicated transmission line that matched combined power output data. this paper suggests two calculation method. First method is select the plant has the largest capacity, and use it's meteorological data as line meteorological data. Second method is average with weight that given according to plants' capacity. In case study, suggested methods are applied to real data. Then use calculated data to Renewable forecasting and analyze the forecasting results.

신뢰적인 전력선 통신을 위한 라인 커플러의 개발 (Development of the line coupler for reliable power line communication system)

  • 최원호;임병노;박종연
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.2009-2010
    • /
    • 2006
  • This paper presents an adaptive line coupler to match input impedance of the Power line Communication(PLC) modem between access impedance of the power line. This line coupler provides maximum signal power transmiting capability, high reliability. The structure of this coupler is simple and designed to make a easy and low cost. The proposed line coupler is suitable for Amplitude Shift Keying(ASK) or Phase Shift Keying(PSK) modem. To figure out our models, the analysis of the transmitting features of power line channel is performed in the time domain at the carrier frequency. As a result of this study, we present the values of capacitors in the capacitor bank and adaptive line coupler circuit.

  • PDF

PN 시퀀스 방식의 광대역 임펄스 응답 측정을 통한 고압 배전선로 채널 특성 연구 (A Study On The Characteristics Of The Medium Voltage Power Distribution Line Channel By Wideband Channel Impulse Response Measurement Using PN Sequence)

  • 오휘명;최성수;이재조;김관호;황금찬
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제54권1호
    • /
    • pp.56-60
    • /
    • 2005
  • In the power-line communication(PLC) systems, the power line is a wired medium. However, the power line channel has the multi-path fading characteristics like the wireless channel in the wireless communication systems because it has the signal reflection and divergence by the impedance mismatching between many branch lines and loads. So the analysis of the multi-path characteristics is very important, and it has been doing by the several measurement methods for the impulse response between the transmitter and the receiver. PN sequence method has originally been used as a wideband impulse response measurement mettled for wireless channel, but it is recently being applied to not only the wireless channel but also the wired channel like the power line channel. This method is more useful and effective for the long distance communication channel like the medium voltage power distribution line with the multi-paths[1]. In this thesis, we have measured impulse response for the medium voltage power distribution line channel by the wideband measurement method using PN sequence, analytically studied the measured data and presented the results.