• 제목/요약/키워드: Power inverter

Search Result 3,965, Processing Time 0.039 seconds

Lossless Inductor Snubber-Assisted ZCS-PFM High Frequency Series Resonant Inverter for Eddy Current-Heated Roller

  • Feng Y. L.;Ishitobi M.;Okuno A.;Nakaoka M.;Lee H. W.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.304-308
    • /
    • 2001
  • This paper presents a novel prototype of ZCS-PFM high frequency series resonant inverter using IGBT power module for electromagnetic induction eddy current-heated roller in copy and printing machines. The operating principle and unique features of this voltage source half bridge inverter with two additional soft commutation inductor snubber are presented including the transformer modeling of induction heated rolling drum. This soft switching inverter can achieve stable zero current soft commutation under a discontinuous and continuous resonant load current for a widely specified power regulation processing. The experimental results and computer-aided analysis of this inverter are discussed from a practical point of view.

  • PDF

An Improved Carrier-based SVPWM Method By the Redistribution of Carrier-wave Using Leg Voltage Redundancies in Generalized Cascaded Multilevel Inverter

  • Kang, Dae-Wook;Lee, Yo-Han;Suh, Bum-Seok;Park, Chang-Ho;Hyun, Dong-Seok
    • Journal of Power Electronics
    • /
    • v.1 no.1
    • /
    • pp.36-47
    • /
    • 2001
  • The carrier-based space vector pulse width modulation(SVPWM), which is considered as highly simple and efficient PWM technology, can be also used in multilevel inverters. The method was originally designed for the two-level inverter and developed to the diode clamped multilevel inverter structure. however it may be noted that it also cause bad switch utilization in cascaded multilevel inverter. This paper introduces an improved carrier-based SVPWM scheme, which is fully suitable for cascaded multilevel inverter topologies because it can achieve the optimized switch utilization through the redistribution of the triangular carrier waves considering leg voltage redundancies while having the advantages of the conventional carrier-based SVPWM. Using simulation and experimental results, the superior performance of new PWM method is shown.

  • PDF

Design and manufacture of Inverter for Driving Electrode Fluorescent Lamp (외부전극 형광램프 구동용 인버터 설계 및 제작)

  • Yoon, Dong-han
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.6 no.2
    • /
    • pp.76-80
    • /
    • 2013
  • In this paper, a external electrode fluorescent lamp driving inverter for LCD backlight is designed. AC input from a lamp-driven system to process up to two inverter system for the existing configuration of power-efficient than the system as well as to increase the volume and weight reduction, Furthermore low-cost advantage. AC power input in order to drive EEFL stable and AC 85V ~ 265V power factor increase in the PFC Block can be used for running the Inverter Block EEFL and composed.

Robust Control of a Grid Connected Three-Phase Two-Level Photovoltaic Inverter (3상 2레벨 계통연계형 태양광 인버터의 강인제어)

  • Ahn, Kyung-Pil;Lee, YoungIl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.538-548
    • /
    • 2014
  • This study provides a robust control of a grid-connected three-phase two-level photo voltaic inverter. The introduced control method uses the cascade control strategy to regulate AC-side current and DC-link voltage. A robust controller with integration action is used for the inner-loop AC-side current control, which maximizes the convergence rate using a linear matrix inequality-based optimization design method and eliminates the offset error. The robust controller design method considers the parameter uncertainty set to accommodate parameter mismatch and un-modeled components in the inverter model. An outer-loop proportional-integral controller is used to regulate DC-link voltage with linearization of DC/AC relation. The proposed control strategy is applied to a grid-connected 100 kW photo voltaic inverter.

Design and Implementation of Low Cost Boost Type Single-Phase Inverter System for Compensation of Voltage Sag (순간전압강하 보상을 위한 저가의 승압형 단상 인버터 시스템의 설계 및 구현)

  • Lee, Seung-Yong;Hong, Soon-Chan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.85-92
    • /
    • 2012
  • In this paper, a 300[W] class boost type single-phase inverter system which can compensate voltage sag on source side is designed and implemented. This system is a two-stage conversion system composed of a boost converter and a PWM inverter. If the voltage sag has appeared at the point of common coupling, the boost converter would be operated to compensate it. The boost converter and the inverter were constructed on single smart power module(SPM) to implement low cost system. The system is designed for that the THD of output voltage is below 5[%]. Finally, the validity of the design for the inverter system is verified by both simulations and experiments.

A New Islanding Detection Method using Phase-Locked Loop for Inverter-Interfaced Distributed Generators

  • Chung, Il-Yop;Moon, Seung-Il
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.165-171
    • /
    • 2007
  • This paper proposes a new islanding detection method for inverter-interfaced distributed generators (DG). To detect islanding conditions, this paper calculates the phase angle variation of the system voltage by using the phase-locked loop (PLL) in the inverter controllers. Because almost all inverter systems are equipped with the PLL, the implementation of this method is fairly simple and economical for inverter-interfaced DGs. The detection time can also be shortened by reducing communication delay between the relays and the DGs. The proposed method is based on the fact that islanding conditions result in the frequency and voltage variation of the islanded area. The variation depends on the amount of power mismatch. To improve the accuracy of the detection algorithm, this paper injects small low-frequency reactive power mismatch to the output power of DG.

A Study on Grid-connected Photovoltaic Current-Source Inverter using Parallel Connection (병렬연결을 이용한 계통연계형 태양광 전류형 인버터에 관한 연구)

  • Lim, Joung-Min;Cheang, Eui-Heang;Moon, Chae-Joo;Chang, Young-Hak;Kim, Eui-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1222-1223
    • /
    • 2007
  • This paper suggests a 6-pulse-shift converter with PWM current-source inverter based on buck-boost configuration to improve the efficiency and to reduce the switching frequency of inverter for photovoltaic generation system, the device can be operated as interface system between solar module system and power system grid without energy storage cell. the circuit has six current-source buck-boost converter which operate chopper part has one full bridge inverter which make a decision the polarity of AC output. Therefore, the proposed PWM power inverter has advantages such as the reduction of witching loss and realization of unity power factor operation. the theoretical backgrounds are discussed and the input-output characteristics for the implemented prototype inverter using TMS320F2812 are verified experimentally in this paper.

  • PDF

Constant Frequency Adjustable Power Active Voltage Clamped Soft Switching High Frequency Inverter using The 4th-Generation Trench-Gate IGBTs

  • Miyauchi T.;Hirota I.;Omori H.;Terai H.;Abdullah Al Mamun;Nakaoka M.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.236-241
    • /
    • 2001
  • This paper presents a novel prototype of active voltage-clamping capacitor-assisted edge resonant soft switching PWM inverter operating at a constant frequency variable power (VPCF) regulation scheme, which is suitable for consumer high-power induction-heating cooking appliances. New generation IGBT with a trench gate is particularly improved in order to reduce conduction loss due to its lowered saturation voltage characteristics. The soft switching load resonant and quasi-resonant inverter designed distinctively using the latest IGBTs is evaluated from an experimental point of view.

  • PDF

Inverter Driven Air-Conditioner With Power Factor Correction Circuit (역률제어회로를 갖는 인버터 구동 에어컨)

  • 권경안;박병욱;김정태;정용채
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.1
    • /
    • pp.105-110
    • /
    • 1999
  • This paper describes the inverter driven air-condetioner with power factor correction (PFC) circuit. By adopting PFC in the rectifier, we can reduce harmonic injection into power line, improve the efficiency and lower the total system cost compared to conventional inverter only. Also, system performance is improved by stabilizing the output voltage of PFC. In this paper, detailed design procedures for PFC are given, and the several merits with PFC are verified through the simulation and experiment.

Voltage Source Resonant Inverter for Excimer Gas Discharge Load

  • Koudriavtsev, Oleg;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • v.2 no.3
    • /
    • pp.206-211
    • /
    • 2002
  • Silent gas discharge method has been widely applied fur ozone production, ultraviolet light and UV laser generation. Since ozone and ultraviolet applications have tendency to spread widely in industry, the development of efficient and low - cost power supply for such systems is an important task at present. This paper introduces high-frequency inverter type mode power supply designed fur ozone generation tube and ultraviolet generation excimer lamp and considerations on the design of the inverter and pulse density modulation control strategy applied in it.