• Title/Summary/Keyword: Power generation technology

Search Result 2,186, Processing Time 0.039 seconds

A study on An Optimal Protection System for Power Distribution Networks by Applying Multi-Agent System (Multy-agent system을 애용한 배전계통 최적 보호시스템 연구)

  • Jung, K.H.;Min, B.W.;Lee, S.J.;Choi, M.S.;Kang, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.299-301
    • /
    • 2003
  • In this paper, a protection system using Multi-Agent concept for power distribution network is proposed. Multi agent system consist of Feeder agent, OCR(Over Current Relay) agent, Recloser agent and Switch agent. An agent calculates and corrects its parameter by itself through communication with neighboring agents and its own intelligence algorithm. Simulations in a simple distribution network show the effectiveness of the suggested protection system. Multi-Agent System, protection of distribution network, Communication.

  • PDF

Data Compression using Waveform Comparison (파형 비교를 이용한 데이터 압축 기법)

  • Sung, S.M.;Lim, S.I.;Lee, S.J.;Bae, Y.J.;Jin, Y.W.;Kim, J.H.;Kim, B.J.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.151-153
    • /
    • 2003
  • This paper was studied on using data of the protective relay by Power Quality Monitor. The protective relay will have problem to save data for PQM(Power Qualify Monitoring) analysis because the protective relay memory is limited. So this paper was proposed new data compression of the data was get from the protective relay. The scheme is compared each cycle after DFT(Discrete Fourier Transform). And scheme is verified through simulation of protective relay data was from real distribution system.

  • PDF

The Development and Application of a Training Base for the Installation and Adjustment of Photovoltaic Power Generation Systems

  • Chuanqing, SUN
    • International Journal of Advanced Culture Technology
    • /
    • v.4 no.1
    • /
    • pp.37-50
    • /
    • 2016
  • In recent years, the development and application of green energy resources have attracted more and more /$^*$ 'tention of people. The training room presented here is focused on the terminal applications of a photovoltaic power generation system (PPGS). Through introducing the composition and the general design principles, we aimed at leading the students to master the fundamental skills required for its design, installation and construction. The training room consists of numerous platforms, such as: PPGS, Wind and Photovoltaic Hybrid Power Generation Systems, Wind Power Generation Equipments, Simulative Grid-Connected Power Generation System, Electronic Technology Application of New Energy, etc. This enables the students to obtain their project and professional skills training via assembling, adjusting, maintaining and inspecting, etc., various component parts of the photovoltaic and new energy power generation systems, to further grasp the fundamental and related theoretical knowledge, and to further reinforce their practical and operational skills, so as to improve their problem-analyzing and problem-solving abilities.

A Restoration Algorithm using Moving the tie Switch in Distribution System in case of Fault Occur in Power system Substation MTR (변전소 내 주변압기 사고 발생 시 배전계통 연계점 이동을 통한 복구 알고리즘)

  • Hong, Jun-Ho;Lee, Seung-Jae;Choi, Myeon-Song;Lim, Il-Hyung;Kim, Tae-Wan
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.159_160
    • /
    • 2009
  • In this paper proposes a new algorithm of efficiency outage restoration using a outage load switching to a healthy MTR a fault occurrence at a MTR. In addtion, proposed algorithm includes a outage restoration method which keeps MTR optimal capacity with reorganization of distribution network in case it can not restore outage state loads caused by shortage of healthy MTR remain capacity. In case that proposed sequence still can not complete restoration, this paper suggests a efficiency outage restoration with objective function included priority in outage loads.

  • PDF

Adaptive Over Current Relay for power systems having Decentralized Generator (분산전원용 적응형 과전류 계전기)

  • Kim, Hyung-Kyu;Song, Hwang-Bin;Ahn, Jong-Pil;Jeong, Cheal-Hyun;Kang, Sang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.195-196
    • /
    • 2008
  • Output of wind generators are changed by windy level. The change of the output also affects the amplitude of fault current. And this fault current causes OCR's mal-operation. To solve the problem, this paper adopts that Over Current Relay adapted for Decentralized generator algorithm.

  • PDF

A Development of MMI using Open Interface (Open Interface를 적용한 MMI 개발)

  • Oh, S.M.;Min, B.U.;Lee, S.J.;Choi, M.S.;Yoon, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.253-255
    • /
    • 2002
  • The paper presets the improvements of MMI at the PROSET2000 correction program which is totally computerized system of the power system protection. The Base Form that is an open interface is developed to be able to compose the screen by reading the input screen from the database. It also is developed to be suitable for the environment of the Graphical User Interface instead of the DOS window when the users do the pannel settings. Program development in this paper is designed by Unified Modeling Language(UML) techniques.

  • PDF

Examination with Transmission Line Distance Relay Setting Rule Considering Error (오차를 고려한 송전선 보호 거리계전 정정룰에 대한 고찰)

  • Cho, Seong-Jin;Choi, Myeong-Song;Hyun, Seung-Ho;Kim, Joung-Wook;Lee, Joo-Wang;Cho, Bum-Sub;Yoo, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.12-15
    • /
    • 2002
  • Korea Power System Protection Setting Rule was used from the rectify 1990's. Thereafter transmission voltage is raised the voltage into 765kV, and introduction to new technology of Power System, and was many of variation but, it is using. The present is using Digital type distance relay for 765kV transmission line protection. If impedance value of transmission line were to value lower than setting, this would be operating and relay setting rule is for 85% into Zone 1 self section, and Zone 2 is a 125%, Zone 3 is a 225%. Which's $15{\sim}25%$ include current transformer error 5%, potential transformer 5%, relay calculation error 5% and margin factor from the field experience. This paper is discussed transmission protective relay and relay setting rule of high voltage power system and we verify the correctness relay setting rule with distance relay using Matlab simulation.

  • PDF

The Realization of a Transmission Line Protection IED based on IEC61850 (IEC61850 기반 송전선 보호 IED 구현)

  • Kim, Cheol-Hun;Kwon, Young-Jin;Lee, Dong-Gyu;Ryu, Ki-Chan;Kang, Sang-Hee;Nam, Soon-Ryul
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.6-8
    • /
    • 2006
  • 변전소 자동화 시스템에서 IED(Intelligent Electronic Device)들 간의 효과적인 통신을 위해 표준프로토콜인 IEC-61850이 제시되면서 이를 구현하고 응용하기 위한 관심이 높아지고 있다. 본 논문은 IEC-61850 표준규격을 분석하여 제시된, 거리 계전 IED 모델을 이용해 송전선 보호 IED를 구현하였다. 통신기능 구현은 리눅스 커널 2.6 기반의 통신보드를 사용하였고 계전 알고리즘의 수행은 TMS320C32 기반의 DSP(Digital Signal Processor) 보드를 사용하였다. 보드간 통신은 CAN(Cont roller Area Network) 통신으로 이루어 졌으며 사례연구를 위해 RTDS(Real Time Digital Power System Simulator)를 이용하여 입력신호를 생성하였다. 구성된 시스템의 검증을 위해 거리계전기에서 후비보호 시 발생할 수 있는 문제점을 시뮬레이션 하였다.

  • PDF

The Study on Correction of Protective Relaying Set Value for the Power Electric Network Paralleled with Wind Farm (풍력전단지의 계통 연계 운전에 따른 보호 계전기 설정치 정정에 관한 고찰)

  • Jang, Sung-Il;Choi, Don-Man;Choi, Jeong-Hwan;Kim, Kwang-Ho;Oh, Jong-Youl;Kim, Joo-Yearl
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.487-490
    • /
    • 2002
  • Wind farm paralleled with electric power network can supply the power into a power network not only the normal conditions, but also the fault conditions of distribution network. If the fault happened in the power line with wind farm, the fault current level measured in a relaying point might be lower than that of distribution network without wind turbine generator. Consequently, it is difficult to detect the fault happened in the distribution network connected with wind generator. This paper describes the influence of wind turbine generator on the protective relaying system for detecting the fault occurred in a power line network. Simulation results shows that the fault current depends on the fault impedance, location, and the capacity of wind farm and distribution network load.

  • PDF

Implementation of an Over-Current Relaying Algorithm with TMS320C32 (TMS320C32를 이용한 한시 과전류 계전기의 구현)

  • Yoo, Sung-Rok;Yoon, Byung-Wook;Park, Byung-Woo;Choi, Chang-Yung;Kang, Sang-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2193_2194
    • /
    • 2009
  • A digital over current relay(OCR) is realized by using TMS320C32 microprocessor. Fourier Transform is used to obtain the phasor of a current signal and a 2nd low pass filter is adopted to prevent aliasing error. H/W test shows almost same results with those of the S/W test. It could be possible that confirm simularity between H/W and S/W test in this paper.

  • PDF