• Title/Summary/Keyword: Power frequency voltage

Search Result 2,930, Processing Time 0.038 seconds

Development of Signal Coupler for Power Line Communication over Medium Voltage Distribution Line (고압 배전선로 전력선 통신 신호결합장치 개발)

  • Lee Jae-Jo;Park Young-Jin;Oh Hui-Myoung;Kim Kwan-Ho;Lee Dae-Young
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.6
    • /
    • pp.409-416
    • /
    • 2005
  • For broadband high-data-rate power line communication with the allocated frequency bandwidth from 2 to 30 MHz on medium voltage (MV) distribution power lines, a signal coupling unit is developed. The coupling unit is composed of a coupling capacitor for coupling communication signal, a drain coil, and an impedance matching part. The coupling capacitor made of ceramic capacitor is designed for transmission property of better than 1 dB in the frequency range. The drain coil is used for preventing low frequency high voltage from junction of medium voltage power line in case that a coupling capacitor is not working properly any more. Also, using ferrite core, a novel broadband impedance matching transformer is developed. A complete coupling unit with a coupling capacitor, a drain coil, and a matching transformer is housed by polymer for good isolation and distinguishing from high voltage electric facilities. Each is fabricated and its frequency behavior is tested. Finally, complete signal couplers are equipped in a MV PLC test bed and their performance are measured. The measurement shows that the coupling capacitor works excellently.

Phase Angle Control in Resonant Inverters with Pulse Phase Modulation

  • Ye, Zhongming;Jain, Praveen;Sen, Paresh
    • Journal of Power Electronics
    • /
    • v.8 no.4
    • /
    • pp.332-344
    • /
    • 2008
  • High frequency AC (HFAC) power distribution systems delivering power through a high frequency AC link with sinusoidal voltage have the advantages of simple structure and high efficiency. In a multiple module system, where multiple resonant inverters are paralleled to the high frequency AC bus through connection inductors, it is necessary for the output voltage phase angles of the inverters be controlled so that the circulating current among the inverters be minimized. However, the phase angle of the resonant inverters output voltage can not be controlled with conventional phase shift modulation or pulse width modulation. The phase angle is a function of both the phase of the gating signals and the impedance of the resonant tank. In this paper, we proposed a pulse phase modulation (PPM) concept for the resonant inverters, so that the phase angle of the output voltage can be regulated. The PPM can be used to minimize the circulating current between the resonant inverters. The mechanisms of the phase angle control and the PPM were explained. The small signal model of a PPM controlled half-bridge resonant inverter was analyzed. The concept was verified in a half bridge resonant inverter with a series-parallel resonant tank. An HFAC power distribution system with two resonant inverters connected in parallel to a 500kHz, 28V AC bus was presented to demonstrate the applicability of the concept in a high frequency power distribution system.

Zero Voltage Soft Switching PWM High-Frequency Inverter with Active Inductor Snubber for Induction Heated Roller in New Type Copy Machine

  • Muraoka S.;Feng Y.L.;Kunimoto H.;Chandhaket S.;Okuno A.;Nakaoka M.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.75-79
    • /
    • 2001
  • This paper presents a novel version of an active voltage clamped ZVS-PWM high frequency inverter using IGBTs for electromagnetic induction eddy current-based rolling drum heating in new generation copy and printing machines in consumer business use. The operating principle of this inverter circuit and unique features are described herein. Its constant frequency duty cycle (asymmetrical PWM) controlled voltage source quasi-resonant soft switching high frequency inverter employing IGBTs is proposed, which is capable of achieving stable and efficient zero voltage soft switching commutation over a widely specified power regulation range from full power to low power. The operating performances in a steady state of this inverter is discussed and evaluated on basis of simulation and experimental results as an induction heated roller in new generation copy machine.

  • PDF

Optimized Design of Bi-Directional Dual Active Bridge Converter for Low-Voltage Battery Charger

  • Jeong, Dong-Keun;Ryu, Myung-Hyo;Kim, Heung-Geun;Kim, Hee-Je
    • Journal of Power Electronics
    • /
    • v.14 no.3
    • /
    • pp.468-477
    • /
    • 2014
  • This study proposes an optimized design of a dual active bridge converter for a low-voltage charger in a military uninterrupted power supply (UPS) system. The dual active bridge converter is among various bi-directional DC/DC converters that possess a high-efficiency isolated bi-directional converter. In the general design, the zero-voltage switching(ZVS) region is reduced when the battery voltage is high. By contrast, efficiency is low because of high conduction losses when the battery voltage is low. Variable switching frequency is applied to increase the ZVS region and the power conversion efficiency, depending on battery voltage changes. At the same duty, the same power is obtained regardless of the battery voltage using the variable switching frequency. The proposed method is applied to a 5 kW prototype dual active bridge converter, and the experimental results are analyzed and verified.

RF Channel Characteristics of the Medium-voltage Power Line for PLC (전력선통신을 위한 중 전압용 전력선의 RF채널 특성)

  • Kim, Seon-Hyo;Kim, Gwan-Ho;Lee, Hyeong-Cheol;Sin, Cheol-Jae
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.7
    • /
    • pp.316-321
    • /
    • 2002
  • In this Paper, the channel characteristics of the medium voltage(22.9kV) power line to analysis the broadband power line communication in the frequency range up to 30MHz was measured. With the sideband electrical coupler in the operating frequency range from DC to 30MHz, we measured characteristic impedance, noise and attenuation of the medium voltage power line, and then characteristic impedance was measured at the state of unloaded medium voltage power line by Scattering parameter method of Vector Network Analyzer. As a measurement result, Channel impedance shows 100~380$\Omega$ at the less than 15MHz and 70~230$\Omega$ at the more than 15 MHz. Noise characteristics of power line shows -75dBm at 20MHz and Narrowband interference noise was from 3 MHz to 7MHz.

The analysis result of temporary operation of 765 kV transmission line as 345 kV rating (765 kV 송전선로의 345 kV 운전에 따른 계통 해석)

  • Woo, J.W.;Shim, E.B.;Kang, Y.W.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1647-1649
    • /
    • 1998
  • This paper describes the power frequency voltage and its countermeasure when a 765 kV transmission line is directly connected to a 345 kV line and operated at 345 kV voltage. The summary of this result is as follows : The western route of 765 kV transmission line doesn't need any countermeasure to reduce the power frequency voltage at the receiving end. The eastern route of 765 kV transmission needs 100 Mvar(3 phase) capacity of shunt reactor at the receiving end to reduce the power frequency voltage. The use of shunt reactors in the 765 kV transmission lines has unexpected problems, one of which is induction of high voltages on a de-energized circuit of two parallel lines. This paper examined the problem of resonance on two parallel transmission circuits in one routes.

  • PDF

The Characteristics on the Removal of Bacteria Using High Voltage and High Frequency Pulsed Power System (고압 고주파 펄스 파워 시스템을 이용한 세균 제거 특성)

  • Shim, Ji-Young;Kim, Mi-Jeong;Park, Je-Wook;Kim, Hee-Je
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1416-1417
    • /
    • 2007
  • The high frequency pulsed power system is widely available for use in high frequency generator applications. We designed and fabricated our own high frequency pulsed power system to obtain very sort pulse width and high peak value and investigated microbe removal characteristics using it. This paper introduces a simple high voltage high frequency pulsed power system for removing various bacteria caused by dirty water. This system include power supply circuit, switching MOSFET, and flyback converter. We can also control the switching using a PIC one chip microprocessor. As a result, we can obtain good removing characteristics of various bacteria by adjusting the charging voltage, the pulse repetition rate and the electrical field inducing time.

  • PDF

Design of nonlinear controller for voltage and frequency of power system using excitation and governor system (여자기와 거버너를 이용한 전력계통 단자전압과 주파수의 비선형제어)

  • Im, Sun;Yoon, Tae-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.669-671
    • /
    • 2004
  • This paper presents a MIMO nonlinear controller for the power system consisting of a turbine and a synchronous generator connected to an infinite bus. The controller proposed is based on feedback input-output linearization; its main goal is to regulate the terminal voltage and frequency, and is to improve the transient stability under large disturbances and unexpected faults. It is guaranteed that the voltage converges to its reference value exponentially, and that the frequency and the mechanical/electrical power are bounded. The design procedure is tested on a single machine infinite bus power system through simulations, and is seen to be effective.

  • PDF

A Voltage and Frequency Controller for Stand Alone Pico Hydro Generation

  • Kasal, Gaurav Kumar;Singh, Bhim
    • Journal of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.267-274
    • /
    • 2009
  • This paper deals with a voltage and frequency (VF) controller for an isolated power generation system based on an asynchronous generator (AG) driven by a pico hydro turbine. The proposed controller is a combination of a static compensator (STATCOM) and an electronic load controller (ELC) for decoupled control of the reactive and active powers of the AG system to control the voltage and frequency respectively. The proposed generating system along with its VF controller is modeled in MATLAB using SIMULINK and PSB (Power System Block Sets) toolboxes. The performance of the controller is verified for the proposed system and feeding various types of consumer load such as linear/non-linear, balanced/unbalanced and dynamic loads.

Battery Energy Storage Based Voltage and Frequency Controller for Isolated Pico Hydro Systems

  • Singh, Bhim;Rajagopal, V.
    • Journal of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.874-883
    • /
    • 2009
  • This paper deals with an integrated voltage and frequency (VF) controller for isolated asynchronous generators (IAG) driven by a constant power pico-hydro uncontrolled turbine feeding three-phase four-wire loads. The proposed VF controller is used to control the frequency and voltage of an IAG with load leveling. Such a VF controller is also known as an integrated electronic load controller (IELC) which is realized using an isolated star/polygon transformer with a voltage source converter (VSC) and a battery at its DC bus. The proposed generating system with a VFC is modeled and simulated in MATLAB along with Simulink and Simpower system (SPS) toolboxes. The simulated results are presented to demonstrate the performance of an isolated asynchronous generator feeding three-phase four-wire loads with neutral current compensation.