Causes and Overcoming of the Algae Excess in a Dam Water - Based on the Data of Water Quality Analysis of Mulgum Area - (댐호화된 하천의 조류 과다 발생원인과 해소 방안 - 낙동강 물금 지역의 수질 분석 데이터를 중심으로 -)

  • Yang, Shi-Chun;Xia, Tian-Tian;Kang, Tai-Ho
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.20 no.4
    • /
    • pp.1-13
    • /
    • 2017
  • The purpose of this study is to analyze a term of decade of water quality data of the Mulgum intake station on the Nakdong river(dam) to find the cause of algal blooms and to set an alternative to prevent artificial lake water pollution. Our study shows that water quality changes have regular periodic regularity and there was a certain correlation between specific analytical items. According to the analysis results of each factor, the decline in precipitation was not the main reason for algal blooms. TP concentration had a slight effect on Chl-a concentration but was not a limiting nutrient of a bloom. TN concentration had a strong correlation with Chl-a and strongly negative correlation with temperature, but was not a bloom's limiting nutrient, and was only a dependent variable. As the temperature was negatively correlated with the Chl-a concentration, it is found that the aspect of the ecological influence of the temperature was the most important factor of the phytoplankton concentration change. The N/P ratio lies under a power function with a high degree of reliability by the TP concentration, and the phenomenon appeared to be the same as the results of two other comparative areas. This result confirms that TN is dependent on TP and the biota in the lake that TN is a dependent variable whose concentration is determined by TP it. In conclusion, the increase in lake bloom is the result of a food chain change, and it is necessary to control the ecosystem by the food chain in the lake in order to reduce the lake's bloom. In particular, it is important to keep the benthic ecosystem as wide as possible in the aerobic state.

Blazed $GxL^{TM}$ Device for Laser Dream Theatre at the Aichi Expo 2005

  • Ito, Yasuyuki;Saruta, Kunihiko;Kasai, Hiroto;Nshida, Masato;Yamaguchi, Masanari;Yamashita, Keitaro;Taguchi, Ayumu;Oniki, Kazunao;Tamada, Hitoshi
    • Journal of Information Display
    • /
    • v.8 no.2
    • /
    • pp.10-14
    • /
    • 2007
  • A blazed $GxL^{TM}$ device is described as having high optical efficiency (> 70% for RGB lasers), and high contrast ratio (> 10,000:1), and that is highly reliable when used in a large-area laser projection system. It has a robust design and precise stress control technology to maintain a uniform shape (bow and tilt) of more than 6,000 ribbons, a $0.25-{\mu}m$ CMOS compatible fabrication processing and planarization techniques to reduce fluctuation of the ribbons, and a reliable Al-Cu reflective film that provided protection against a high-power laser. No degradation in characteristics of the GxL device is observed after operating a 5,000- lumen projector for 2,000 hours and conducting 2,000 temperature cycling tests at $-20^{\circ}C$ and $+80^{\circ}C$. At the 2005 World Exposition in Aichi, Japan the world's largest laser projection screen with a size of 2005 inches (10 m ${\times}$ 50 m) and 6 million pixels (1,080 ${\times}$ 5,760) was demonstrated.

Performance of 8SQAM System in a Nonlinearly Amplified Channel Environment (비선형 증폭 채널 환경에서 8SQAM 시스템의 성능)

  • 성봉훈;서종수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.7C
    • /
    • pp.669-677
    • /
    • 2003
  • A new Modem technique - 8SQAM(8-state Superposed Quadrature Amplitude Modulation) - for use in power and bandwidth limited digital communication system is proposed. 8SQAM is free of inter-symbol interference(ISI) and generates output signals which have a smooth and continuous phase transition and a reduced envelope fluctuation by keeping correlation between amplitudes and phases of two subsequent symbols. Accordingly, 8SQAM, as compared with a conventional 8PSK, is influenced a little by ISI and inter-modulation(IM) caused by nonlinear distortions. In this paper, the performance of the 8SQAM system, in a nonlinearly amplified channel impaired by additive white Gaussian noise(AWGN), ISI and IM, is analyzed via computer simulation. The simulation result shows that 8SQAM outperforms 8PSK with roll-off value of $\alpha$=0.25 by 2.5dB in CNR to maintain BER=1$\times$10$^{-4}$ when input back-off(IBO) of HPA is 3dB.

Underwater Acoustic Communication Channel Modeling Regarding Magnitude Fluctuation Based on Ocean Surface Scattering Theory and BELLHOP Ray Model and Its Application to Passive Time-reversal Communication (해수면에 의한 신호 응답 강도의 시변동성 특성이 적용된 벨홉 기반의 수중음향 통신 채널 모델링 및 수동 시역전 통신 응용)

  • Kim, Joonsuk;Koh, Il-Suek;Lee, Yongshik
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.2
    • /
    • pp.116-123
    • /
    • 2013
  • This paper represents generation of time-varying underwater acoustic channels by performing scattering simulation with time-varying ocean surface and Kirchhoff approximation. In order to estimate the time-varying ocean surface, 1D Pierson-Moskowitz ocean power spectrum and Gaussian correlation function were used. The computed scattering coefficients are applied to the amplitudes of each impulse of BELLHOP simulation result. The scattering coefficients are then compared with measured doppler spectral density of signal components which were scattered from ocean surface and the correlation time used in the Gaussian correlation function was estimated by the comparison. Finally, bit-error-rate and channel correlation simulations were performed with the generated time-varying channel based on passive time-reversal communication scenario.

Performance and Variation-Immunity Benefits of Segmented-Channel MOSFETs (SegFETs) Using HfO2 or SiO2 Trench Isolation

  • Nam, Hyohyun;Park, Seulki;Shin, Changhwan
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.4
    • /
    • pp.427-435
    • /
    • 2014
  • Segmented-channel MOSFETs (SegFETs) can achieve both good performance and variation robustness through the use of $HfO_2$ (a high-k material) to create the shallow trench isolation (STI) region and the very shallow trench isolation (VSTI) region in them. SegFETs with both an HTI region and a VSTI region (i.e., the STI region is filled with $HfO_2$, and the VSTI region is filled with $SiO_2$) can meet the device specifications for high-performance (HP) applications, whereas SegFETs with both an STI region and a VHTI region (i.e., the VSTI region is filled with $HfO_2$, and the STI region is filled with $SiO_2$) are best suited to low-standby power applications. AC analysis shows that the total capacitance of the gate ($C_{gg}$) is strongly affected by the materials in the STI and VSTI regions because of the fringing electric-field effect. This implies that the highest $C_{gg}$ value can be obtained in an HTI/VHTI SegFET. Lastly, the three-dimensional TCAD simulation results with three different random variation sources [e.g., line-edge roughness (LER), random dopant fluctuation (RDF), and work-function variation (WFV)] show that there is no significant dependence on the materials used in the STI or VSTI regions, because of the predominance of the WFV.

Solvation of a Small Metal-Binding Peptide in Room-Temperature Ionic Liquids

  • Shim, Youngseon;Kim, Hyung J.;Jung, YounJoon
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.11
    • /
    • pp.3601-3606
    • /
    • 2012
  • Structural properties of a small hexapeptide molecule modeled after metal-binding siderochrome immersed in a room-temperature ionic liquid (RTIL) are studied via molecular dynamics simulations. We consider two different RTILs, each of which is made up of the same cationic species, 1-butyl-3-methylimidazolium ($BMI^+$), but different anions, hexafluorophosphate ($PF_6{^-}$) and chloride ($Cl^-$). We investigate how anionic properties such as hydrophobicity/hydrophilicity or hydrogen bonding capability affect the stabilization of the peptide in RTILs. To examine the effect of peptide-RTIL electrostatic interactions on solvation, we also consider a hypothetical solvent $BMI^0Cl^0$, a non-ionic counter-part of $BMI^+Cl^-$. For reference, we investigate solvation structures in common polar solvents, water and dimethylsulfoxide (DMSO). Comparison of $BMI^+Cl^-$ and $BMI^0Cl^0$ shows that electrostatic interactions of the peptide and RTIL play a significant role in the conformational fluctuation of the peptide. For example, strong electrostatic interactions between the two favor an extended conformation of the peptide by reducing its structural fluctuations. The hydrophobicity/hydrophilicity of RTIL anions also exerts a notable influence; specifically, structural fluctuations of the peptide become reduced in more hydrophilic $BMI^+Cl^-$, compared with those in more hydrophobic $BMI^+PF_6{^-}$. This is ascribed to the good hydrogen-bond accepting power of chloride anions, which enables them to bind strongly to hydroxyl groups of the peptide and to stabilize its structure. Transport properties of the peptide are examined briefly. Translations of the peptide significantly slow down in highly viscous RTILs.

Fabrication of a Micro-thermoelectric Probe (마이크로 프로브 기반 열전 센서 제작 기술)

  • Chang, Won-Seok;Choi, Tae-Youl
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.11
    • /
    • pp.1133-1137
    • /
    • 2011
  • A novel technique for the fabrication of a glass micropipette-based thermal sensor was developed utilizing inexpensive thermocouple materials. Thermal fluctuation with a resolution of ${\pm}0.002$ K was measured using the fabricated thermal probe. The sensors comprise unleaded low-melting point solder alloy (Sn) as a core metal inside a borosilicate glass pipette coated with a thin film of Ni, creating a thermocouple junction at the tip. The sensor was calibrated using a thermally insulated calibration chamber, the temperature of which can be controlled with a precision of ${\pm}0.1$ K and the thermoelectric power (Seebeck coefficient) of the sensor was recorded from 8.46 to $8.86{\mu}V$/K. The sensor we have produced is both cost-effective and reliable for thermal conductivity measurements of micro-electromechanical systems (MEMS) and biological temperature sensing at the micron level.

Stabilization of Output Pulses from a Passively Q-switched Nd:YVO4 Laser Pumped by a Continuous-wave Laser Diode (연속 발진 다이오드 레이저로 여기된 수동형 Q-스위치 Nd:YVO4 레이저의 출력 펄스 안정화)

  • Ahn, Seung-In;Park, Yune-Bae;Yeo, Hwan-Seop;Lee, Joon-Ho;Lee, Kang-In;Yi, Jong-Hoon
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.5
    • /
    • pp.276-280
    • /
    • 2009
  • A Cr:YAG crystal was used as a saturable absorber for passive Q-switching of a Nd:$YVO_4$ laser which was pumped by a 1-W continuous wave laser diode. The first surface of the Cr:YAG was high-reflection coated for the pump wavelength. The high-reflection coating improved the absorption efficiency of the pump beam in the Nd:$YVO_4$ through double pass absorption. It also prevented pump beam induced partial bleaching of the Cr:YAG. The peak-to-peak pulse fluctuation of passively Q-switched laser output was approximately 4 %. The minimum pulse-width was measured to be 7.11 ns. Also, the average pulse repetition rate was 9 kHz and the maximum output power was 16.27 mW.

DEVELOPMENT OF THE 5GHZ CONTINUUM RECEIVER SYSTEM (5GHZ대 연속 전파 수신 시스템의 개발)

  • Byeon, Do-Yeong;Choi, Han-Gyu;Lee, Jeong-Won;Gu, Bon-Cheol
    • Publications of The Korean Astronomical Society
    • /
    • v.11 no.1
    • /
    • pp.109-123
    • /
    • 1996
  • We have developed a 5GHz continuum receiver system. The receiver is a direct type receiver. In order to reduce the noise due to the fluctuation of the gain in the amplifiers, the system employs the Dicke switching method. We made the 5GHz low-noise amplifier and the bandpass filter. The low-noise amplifier gives ${\sim}35dB$ gain and has ${\sim}210K$ noise temperature. The bandpass filter has a passband between 4.3 and 5.4GHz. We also made switch driver, video amplifiers, phase detector, and integrator. Using a 1.8 meter offset parabolic antenna, we measured the efficiency of the system. Since the antenna does not have a driver to track objects, observations were performed with the antenna fixed. The measured noise temperature of the system is ${\sim}650K$. From the observation of the blank sky, noise level was measured. It was found that the systematic noise(${\sim}0.5K$: peak to peak value) is much larger than the thermal noise. The systematic noise is possibly related to the stability of the DC power supplied to the receiver system. Besides the noise of the system, it was found that the airplanes are the very serious noise sources. We measured the radio flux of the Sun using the developed system. The observed radio flux of the Sun is ${\sim}10^6Jy$, which is close to the known value of the quiet Sun. The test observation of the Sun shows that the angular beam size of the antenna is ${\sim}2.2^{\circ}$.

  • PDF

Estimation on the Depth of Anesthesia using Linear and Nonlinear Analysis of HRV (HRV 신호의 선형 및 비선형 분석을 이용한 마취심도 평가)

  • Ye, Soo-Young;Baik, Seong-Wan;Kim, Hye-Jin;Kim, Tae-Kyun;Jeon, Gye-Rok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.1
    • /
    • pp.76-85
    • /
    • 2010
  • In general, anesthetic depth is evaluated by experience of anesthesiologist based on the changes of blood pressure and pulse rate. So it is difficult to guarantee the accuracy in evaluation of anesthetic depth. The efforts to develop the objective index for evaluation of anesthetic depth were continued but there was few progression in this area. Heart rate variability provides much information of autonomic activity of cardiovascular system and almost all anesthetics depress the autonomic activity. Novel monitoring system which can simply and exactly analyze the autonomic activity of cardiovascular system will provide important information for evaluation of anesthetic depth. We investigated the anesthetic depth as following 7 stages. These are pre-anesthesia, induction, skin incision, before extubation, after extubation, Post-anesthesia. In this study, temporal, frequency and chaos analysis method were used to analyze the HRV time series from electrocardiogram signal. There were NN10-NN50, mean, SDNN and RMS parameter in the temporal method. In the frequency method, there are LF and HF and LF/HF ratio, 1/f noise, alphal and alpha2 of DFA analysis parameter. In the chaos analysis, there are CD, entropy and LPE. Chaos analysis method was valuable to estimate the anesthetic depth compared with temporal and frequency method. Because human body was involved the choastic character.