• 제목/요약/키워드: Power fail safe

검색결과 28건 처리시간 0.026초

A Study on Design of the Trip Computer for ECC System Based on Dynamic Safety System

  • Kim, Seog-Nam;Seong, Poong-Hyun
    • Nuclear Engineering and Technology
    • /
    • 제32권4호
    • /
    • pp.316-327
    • /
    • 2000
  • The Emergency Core Cooling System in current nuclear power plants typically has a considerable number of complex functions and largely cumbersome operator interfaces. Functions for initiation, switch-over between various phases of operation, interlocks, monitoring, and alarming are usually performed by relays and analog comparator logic which are difficult to maintain and test. To improve problems of an analog based ECC (Emergency Core Cooling) System, the trip computer for ECCS based on Dynamic Safety System (DSS) is implemented. The DSS is a computer based reactor protection system that has fail-safe nature and performs a dynamic self-testing. The most important feature of the DSS is the introduction of test signal that send the system into a tripped state. The test signals are interleaved with the plant signals to produce an output which switches between a tripped and health state. The dynamic operation is a key feature of the failsafe design of the system. In this work, a possible implementation of the DSS using PLC is presented for a CANDU Reactor. ECC System of the CANDU Reactor is selected as the reference system.

  • PDF

비대칭 이중화 EHA의 유압 회로 설계 (Design of a Hydraulic Circuit for an Asymmetrically Dualized Electro-Hydrostatic Actuator)

  • 홍예선;김상석;김대현;김상범;박상준;최관호
    • 항공우주시스템공학회지
    • /
    • 제8권2호
    • /
    • pp.7-13
    • /
    • 2014
  • In order to enable fail-safe operation the electro-hydrostatic actuators can be dualized. When a symmetrical actuator is combined in series with an asymmetrical actuator with single rod cylinder, the flow rates of their cylinders are unmatched. If their position controller has same configuration, one of their pumps can supply too much flow rate under particular load conditions, which should be bypassed into low pressure side e.g. by a relief valve. In this paper it is shown how the hydraulic circuit for the asymmetrically combined electro-hydrostatic actuator can be designed without sacrificing power consumption.

ANSYS를 이용한 스캐폴딩 시스템 타워 구조 건전성 평가에 관한 법공학적 연구 (Forensic Engineering Study on Structural Integrity Evaluation of Scaffolding System Tower using ANSYS)

  • 김종혁;김의수;박우식;문병선;고재모;박남규;윤기봉;조성욱
    • 한국안전학회지
    • /
    • 제28권6호
    • /
    • pp.42-48
    • /
    • 2013
  • Forensic engineering is the application of engineering principles covering the investigation of constructed facilities and systems that fail to perform as intended, causing personal injury or damage to property, environmental, economy etc. In the year 2012, two collapsed accidents of the large scaffolding system in national thermal power station occurred one after another, causing many casualties. In this study, we had performed to investigate the collapsed accident of scaffolding system occurred in the a thermal power station of two accidents. First, the investigation about the collapsed accidents site had performed to understand collapsed state and structures of the scaffolding system. Second, reviewing the materials concerning about the applied weight on the scaffolding system had performed. The applied weight is sum of the weights of the 15 workers, additional materials for coating work and dispersed and loaded shot ball on the foothold etc. the applied weight that calculated exceed more three times than the safe working load. Third, we had confirmed the install state of the materials of the scaffolding system by reviewing the quantity of the materials on the manual and the real system. Last, structural analysis had performed to evaluate structural integrity of the scaffolding system using Ansys. Through a series of this processes, the definite accidents causes of the collapsed scaffolding system revealed. Through these studies, the collapse accident that may occur in the scaffolding system in thermal power station can be minimized by performing specialized and systematic investigation on the accidents in terms of Forensic engineering.

중소형 레이드를 위한 빠른 패리티 재동기화 기법 (A Fast Parity Resynchronization Scheme for Small and Mid-sized RAIDs)

  • 백승훈;박기웅
    • 정보처리학회논문지:컴퓨터 및 통신 시스템
    • /
    • 제2권10호
    • /
    • pp.413-420
    • /
    • 2013
  • 정전 방지 장치가 없는 중소형 레이드 (RAID: redundant arrays of independent disks)는 갑작스런 정전 또는 오류로 인한 종료 이후에 수시간의 긴 재동기화 시간을 요구한다. 레이드에서는 데이터 블록과 패리티 블록이 일관성 있게 갱신되어야 하는데, 데이터를 기록하다가 정전이 되면 데이터 블록은 갱신되었는데 패리티 블록은 갱신되지 않거나 반대인 경우가 발생할 수 있다. 이렇게 부분적으로 갱신된 스트라이프를 반드시 올바른 패리티로 갱신해야 하나 어떤 스트라이프에 이런 문제가 발생하였는지 찾기가 매우 어려웠다. 기존에는 전 저장공간을 검색하고 오류 있는 스트라이프를 수정하는, 수 시간을 요구하는, 패리티 재동기화 방법이 사용되어 왔다. 본 논문은 중소형 레이드에서 낮은 오버헤드를 갖는 고속의 재동기화 기술을 제안한다. 제안하는 기술은 리눅스의 소프트웨어 레이드에서 구현되었다. 성능 실험 결과에 따르면, 제안하는 기법은 재동기화 과정을 200분에서 5초로 단축시키고, 일반 입출력에서 22%의 오버헤드를 2%로 낮추었다.

철도터널구간에서 공간다이버 시티 기법을 이용한 통신채널 모델에 관한 연구 (A Study on the Communication Channel Model Using the Space Diversity Technique in Railroad Tunnel Section)

  • 이상혁;김민석;전태현;이종우
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.1044-1053
    • /
    • 2010
  • Transmitting correct train control information is important in a train control system which demands safety. The train control information includes the maximum speed of trains, position of preceding trains, incline of tracks and curve sections etc. A radio frequency-communication based train control system is influenced by the noise and interference because the train control information is transmitted by wireless between a on-board system and wayside system. The radio frequency-communication based train control system is a mobile communication system due to moving trains. The inter symbol interference(ISI) occurs by the multipath fading in the mobile ommunication system. As signal-to-noise ratio(SNR) is decreased by the ISI, the train control information is not received correctly. In case of tunnel section, numerous reflected waves exist. Therefore, the power density of receiver is decreased by difference among the received times, magnitudes, phases through the multipath. So, the train suddenly is stopped by the fail-safe operation in the train control system on account of decreasing the power density of receiver. In this paper, a line of sight model-(Additive White Gaussian noise(AWGN) channel), rayleigh and rician fading model are presented. Probability density functions which are related to the SNR are derived from the models. The fading phenomenon severely occurs as a result of analyzing the probability density functions. So, the space diversity method is used in order to reduce the fading effect and it is demonstrated by using Matlab program.

  • PDF

직업성 전자장 노출과 백혈병 발생에 관한 메타분석 (Relationship between Occupational Electromagnetic Field Exposure and Leukemia : A Meta-Analysis)

  • 김윤신;송혜향;홍승철;조용성
    • Journal of Preventive Medicine and Public Health
    • /
    • 제33권1호
    • /
    • pp.125-133
    • /
    • 2000
  • Objectives : This study uses meta-analysis methodology to examine the statistical consistency and importance of random variation among results of epidemiologic studies of occupational electromagnetic field exposure and leukemia. Methods : Studies for this meta-analysis were identified from previous reviews and by asking researcher active in this field for recommendations. Overall, 27 studies of occupational electromagnetic field exposures and leukemia were reviewed. A variety of meta-analysis statistical methods have been used to assess combined effects, to identify heterogeneity, and to provide a single summary risk estimate based on a set of simiar epidemiologic studies. In this study, classification of exposure metircs on occupational epidemiologic studies are reported for (1) job classification (20 individual studies); (2) leukemia subtypes (13 individual studies); and (3) country (27 individual studies). Results : Results of this study, an inverse-variance weighted pooling of all the data leads to a small but significant elevation in risk of f 1% (OR=1.11, 95% CI : $1.06\sim1.16$) among 27 occupational epidemiologic studies. Publication bias was assessed by the 'fail-safe n' that may be not influence for all combined results exception a few categories, ie, 'power station operators' and 'electric utility workers' by job classification on occupational study. And ail combined odds ratio results were similar for fixed-effects models and random-effects models, with slightly higher risk estimates for the random-effects model in situations where there was significant heterogeneity, ie, Q-statistic significant (p<.05). Conclusions : We found a small elevation in risk of leukemia, but the ubiquitous nature of exposure to electromagnetic fields from workplace makes even a weak association a public health issue of substantial power to influence the present overall conclusion about relationship between electromagnetic fields exposure and leukemia.

  • PDF

트랙터 부착형 양파수확기의 작업 속도에 따른 견인 부하와 구조 안정성에 관한 실험적 연구 (Experimental Study on the Drawbar Pull and Structural Safety of an Onion Harvester Attached to a Tractor)

  • 신창섭;김준희;하유신;박두산
    • 한국기계가공학회지
    • /
    • 제18권4호
    • /
    • pp.16-25
    • /
    • 2019
  • Recently, due to labor shortages in rural areas within South Korea, the demand for upland-field machinery is growing. In addition, there is a lack of development of systematic performance testing of upland-field machinery. Thus, this study examined structural safety and drawbar pull based on soil properties, as a first step for systematic performance testing on the test bed. First, the properties of soil samples from 10 spots within the experimental site were examined. Second, the strain was measured and converted into stress on 8 points of an onion harvester that are likely to fail. More specifically, the chosen parts are linked to the power, along with the drawbar pull, using a 6-component load cell equipped between the tractor and the onion harvester. The water content of the soil ranged between 5.7%-7.5%, and the strength between 250-1171 kPa. The test soil was subsequently classified into loam soil based on the size distribution ratio of the sieved soil. The onion harvester can be considered as structurally safe based on the derived safety factor and the drawbar pull of 115-1194 kgf, according to the working speed based on agricultural fieldwork.

Configuration assessment of MR dampers for structural control using performance-based passive control strategies

  • Wani, Zubair R.;Tantray, Manzoor A.;Iqbal, Javed;Farsangi, Ehsan Noroozinejad
    • Structural Monitoring and Maintenance
    • /
    • 제8권4호
    • /
    • pp.329-344
    • /
    • 2021
  • The use of structural control devices to minimize structural response to seismic/dynamic excitations has attracted increased attention in recent years. The use of magnetorheological (MR) dampers as a control device have captured the attention of researchers in this field due to its flexibility, adaptability, easy control, and low power requirement compared to other control devices. However, little attention has been paid to the effect of configuration and number of dampers installed in a structure on responses reduction. This study assesses the control of a five-story structure using one and two MR dampers at different stories to determine the optimal damper positions and configurations based on performance indices. This paper also addresses the fail-safe current value to be applied to the MR damper at each floor in the event of feedback or control failure. The model is mathematically simulated in SIMULINK/MATLAB environment. Linear control strategies for current at 0 A, 0.5 A, 1 A, 1.5 A, 2 A, and 2.5 A are implemented for MR dampers, and the response of the structure to these control strategies for different configurations of dampers is compared with the uncontrolled structure. Based on the performance indices, it was concluded that the dampers should be positioned starting from the ground floor, then the 2nd floor followed by 1st and rest of the floors sequentially. The failsafe value of current for MR dampers located in lower floors (G+1) should be kept at a higher value compared to dampers at top floors for effective passive control of multi-story structures.