• 제목/요약/키워드: Power fail safe

검색결과 27건 처리시간 0.039초

지능형 대용량 비례유량제어밸브 서보컨트롤러 설계 (Design of Intelligent Servocontroller for Proportional Flow Control Solenoid Valve with Large Capacity)

  • 정규홍
    • 유공압시스템학회논문집
    • /
    • 제8권3호
    • /
    • pp.1-7
    • /
    • 2011
  • As the technologies of electronic device have advanced these days, most of mechanical systems are designed with electronic control unit to take advantage of control parameter adaption to operating conditions and firmware flexibilities as well. On-board diagnosis, which detects the system malfunction and identifies potential source of error with its own diagnostic criteria, and fail-safe that can switch the mode of operation in view of recognized error characteristics enables easy maintenance and troubleshooting as well as system protection. This paper dealt with the development of diagnosis and fail-safe function for proportional flow control valve. All type of errors related to valve control system components are investigated and assigned to a specific hexadecimal codes. Cumulative error detection algorithm is applied in order for the sensitivity and reliability to be appropriate. Embedded simulator which runs simultaneously with system program provides the virtual error simulation environment for expeditious development of error detection algorithm. The diagnosis function was verified both with solenoid valve and embedded simulator test and it will enhance the valve control system monitoring function.

결함안전 기능을 고려한 교정 반사경 구동장치 (Calibration Mirror Mechanism with Fail-Safe Function)

  • 이경민;오현웅
    • 한국항공우주학회지
    • /
    • 제39권7호
    • /
    • pp.682-687
    • /
    • 2011
  • 일반적으로 탑재 교정을 위한 교정 반사경 구동장치는 교정임무 수행 시에는 주광경로 상의 전개위치로 반사경을 구동하며, 교정 후에는 주광경로와 이격된 수납위치로 반사경을 구동한다. 교정 반사경 구동장치의 결함 발생 시에는 반사경이 전개된 상태로 남아 주광경로를 차단하지 않도록 반사경을 강제 수납한다. 본 논문에서 제안한 결함 안전장치를 가지는 교정용 반사경 구동장치는 구동을 위한 스텝모터, 전개 및 수납 상태확인을 위한 마이크로 스위치, 베어링과 스프링의 기능을 동시에 갖는 피봇베어링 등으로 구성된다. 본 논문에서는 상기의 기능을 갖는 교정 반사경 구동장치 구현을 위한 구동장치 구성을 제안하였으며, 구성요소의 최적화 설계치를 도출하고 기능시험을 통해 결함안전 기능을 갖는 교정 반사경 구동장치의 유효성을 검증하였다.

슈퍼 커패시터를 장착한 풍력발전용 피치 시스템 개발 (The Development of Blade Pitch System Using Super Capacitor Storage)

  • Choi, Hee-young;Ryu, Ji-su;Lee, Sang-ho
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 전력전자학술대회 논문집
    • /
    • pp.311-312
    • /
    • 2012
  • Blade pitch control system monitors and adjusts angle of the blades and controls rotation speed of blades. This paper shows 2MW pitch system hardware and electric part. Blade pitch system consists of pitch drive, gear box, motor and energy storage. Fieldbus is base on CANopen protocol. Fail-Safe system moves the blades to a safety position in case of any fault condition. The super capacitor energy storage provides emergency back up to the Pitch servo driver during feathering the blades. This paper studied Blade pitch servo driver and a bi-directional DC-DC converter for fail-safe system.

  • PDF

10MW급 인텔리전트 디지털 가버너 국산화 개발 및 섬진강 수력 발전소 적용에 관한 연구 (Development of 10MW grade Intelligent Digital Governor and It's Application on Sumjingang Hydro-Power Plant)

  • 전일영;조성훈;김윤식;전시영;신남식;박영철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 D
    • /
    • pp.2153-2155
    • /
    • 2001
  • This thesis presents a development of intelligent digital governing system and it's application on Sumjingang Hydro-Power plant. The developed system consists of hardware, software and governing algorithm. The feature of hardware is triplex-modular fail safe redundant system for a safe turbine running. The software consists of operating system and application program. The operating system has real-time and multi-tasking features. And also, application algorithm is composed to run francis type hydro-turbine. The developed digital governing system is applied to Sumjingang hydro-power plant, Korea Hydro Nuclear Power Corporation.

  • PDF

고 신뢰성 ATS 개발에 관한 연구 (Researches for the Development of High Reliable ATS)

  • 양오;김민호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.2883-2885
    • /
    • 2000
  • ATS(Automatic Transfer Switch), the secondary power supply system prepared for' temporary power fail on main in KEPCO in industrial field or running a important system. is developed. In this development, we prove that the proposed system is safe with results in a few environment testing focused on a solution against a poor environment by making virtual environment for a solution on problems of system reliability to switch more safely.

  • PDF

전기기계 브레이크가 적용된 연료전지 자동차의 회생제동 시스템의 고장해석 (Analysis of Fault Diagnosis of Regenerative Braking System for Fuel Cell Vehicle with EMB System)

  • 송현우;최정훈;황성호;전광기;최성진
    • 드라이브 ㆍ 컨트롤
    • /
    • 제9권4호
    • /
    • pp.8-13
    • /
    • 2012
  • Recently, researches about the eco-friendly vehicles such as hybrid electric vehicle, fuel cell vehicle and electric vehicle have been actively carried out. The regenerative braking system is a key technology to improve the vehicle energy utilization efficiency because it transforms the kinetic energy to the electric energy through the electric motor. This new braking system requires cooperative control between electric controlled brake and regenerative brake. Therefore, it is necessary to establish fault-diagnosis and fail-safe evaluation criteria to secure reliability of the regenerative braking system. In this paper, the failure types and causes in regenerative braking system were analyzed. The transient behavior characteristics were examined based on fault-diagnosis and fail-safe upon failure of regenerative braking system.

자기 유변 유체와 영구 자석을 이용한 회전 엑츄에이터의 개발 (MR rotary brake development with permanent magnet)

  • 권순우;박영진
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1997년도 한국자동제어학술회의논문집; 한국전력공사 서울연수원; 17-18 Oct. 1997
    • /
    • pp.183-186
    • /
    • 1997
  • This paper presents the new MR rotary brake with a permanent magnet, based on the shear operating mode. Due to the permanent magnet, the MR rotary brake can give the nominal resistance to the external disturbance and give the fail safe capacity to the system even when the power supply is accidentally cut off. As we apply the positive or negative current to the electric magnet coil, the resistance torque of the MR rotary brake can be reduced to the value less than the nominal resistance or increased up to the magnetic saturation point.

  • PDF

A Study on Implementation of Dynamic Safety System in Programmable Logic Controller for Pressurized Water Reactor

  • Kim, Ung-Soo;Seong, Poong-Hyun
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 추계학술발표회논문집(1)
    • /
    • pp.91-96
    • /
    • 1996
  • The Dynamic Safety System (DSS) is a compute. based reactor protection system that has fail-safe nature and perform dynamic self-testing. In this paper, the implementation of DSS in PLC is presented for PWR. In order to choose adequate PLC implementation model of DSS, the reliability analysis is performed. The KO-RI unit 2 Nuclear power plant is selected as the reference plant, and the verification is carried out using the KO-RI unit 2 simulator FISA-2.

  • PDF

Sorted compressive sensing for reconstruction of failed in-core detector signals

  • Gyu-ri Bae;Moon-Ghu Park;Youngchul Cho;Jung-Uk Sohn
    • Nuclear Engineering and Technology
    • /
    • 제55권5호
    • /
    • pp.1533-1540
    • /
    • 2023
  • Self-Powered Neutron Detectors(SPNDs) are used to calculate core power distributions, an essential factor in the safe operation of nuclear power plants. Some detectors may fail during normal operation, and signals from failed detectors are isolated from intact signals. The calculated detailed power distribution accuracy depends on the number of available detector signals. Failed detectors decrease the operating margin by enlarging the power distribution measurement error. Therefore, a thorough reconstruction of the failed detector signals is critical. This note suggests a compressive sensing based methodology that rationally reconstructs the readings of failed detectors. The methodology significantly improves reconstruction accuracy by sorting signals and removing high-frequency components from conventional compressive sensing methodology.

NEI 방법론을 적용한 중수로 주제어실의 화재안전정지분석에 관한 연구 (Study of Post-Fire Safe-Shutdown Analysis of a CANDU Main Control Room based on NEI 00-01 Methodology)

  • 김인환;임혁순;배연경
    • 한국화재소방학회논문지
    • /
    • 제30권4호
    • /
    • pp.20-26
    • /
    • 2016
  • 원자력발전소의 화재방호 목적은 예방, 화재의 진압 및 영향을 완화하는 데 있으며, 화재가 발생하면 원자로를 안전하게 정지하여 유지하고 환경으로 방사성물질의 유출을 최소화하는 것이다. 미국의 원자력규제위원회는 10CFR50.48과 10CFR50 APP.R을 발행한 이래 지난 20여년간 화재방호와 관련하여 많은 일반 통신문(Generic Communications)을 발행하였으며, 미국원전 발전사업자(Nuclear Energy Institute)에서는 회로고장 해결을 위한 다중오동작과 관련된 결정론적 방법 등을 사용과 연계하여 위험도정보를 활용한 화재 안전정지분석 방법론을 개발하였다. 본 논문에서는 중수로원전의 주제어실 화재시 화재안전정지분석 방법론을 적용하여 안전정지용 한 계열의 안전관련 계통 및 기기가 손상되어도 원자로의 사고 후 안전정지를 달성하고 유지함을 확인하였다.