• Title/Summary/Keyword: Power data analysis

Search Result 5,291, Processing Time 0.047 seconds

The Effect of Power Sources of Department Store and Fashion Company, and Salesperson's Job Consciousness on Job Satisfaction in the Middle Management System of Department Store (백화점 중간관리 형태에서 백화점 및 패션업체의 권력원천과 판매원의 직업의식이 직무만족에 미치는 영향)

  • Lee, Hyun-Jin;Choo, Tae-Gue
    • Fashion & Textile Research Journal
    • /
    • v.14 no.2
    • /
    • pp.230-241
    • /
    • 2012
  • The purpose of this study was to examine the effect of power sources of department store and fashion company, and salesperson's job consciousness on job satisfaction in the middle management system of department store. Questionnaire data from 193 salespeople in the middle management of department store were analyzed by reliability analysis, factor analysis, correlation analysis, multiple regression analysis, hierarchical regression analysis. The results of this study were as follows: First, coercive power, informational and expert power, and referent power of department store had significant effects on job satisfaction. The coercive power of department store had a negative influence on job satisfaction, while informational and expert power, and referent power of department store had a positive influence on job satisfaction. Second, referent power, expert power, reward power, coercive power of fashion company had a positive influence on job satisfaction. Third, referent power of department store had a greater influence on job satisfaction than other power sources. Fourth, job commitment and pride, prospect awareness had a positive influence on job satisfaction, while professional self-awareness had no effect on job satisfaction.

Demonstration of Voltage Control of DC Distribution System Using Real-time DC Network Analysis Applications (실시간 DC 계통해석 응용프로그램을 이용한 DC 배전망 전압제어 실증 연구)

  • Kim, Hong-joo;Cho, Young-pyo;Cho, Jin-tae;Kim, Ju-yong
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.5 no.4
    • /
    • pp.275-286
    • /
    • 2019
  • This paper presents real-time Direct Current (DC) network analysis applications for operation of DC distribution system or DC microgrid. These applications are installed on central Energy Management System (EMS) and provide solutions of DC network operation. To analysis DC distribution network, this paper proposes composition and sequence of applications. Algorithm of applications is presented in this paper. Demonstration tests are performed on DC distribution site in Gochang Power Testing Center of Korea Electric Power Corporation (KEPCO). To verify the performance, developed DC applications installed on EMS. Scenarios for demonstration test of voltage control are presented. Finally, measured data, application output data and simulation data (by PSCAD/EMTDC) are compared and analyze accuracy of applications.

ANALYSIS ON THE EVALUATION OF PROJECT EFFICIENCY BASED ON BUDGET EXECUTION: PLANNED OUTAGE MAINTENANCE (POM) FOR ELECTRICITY POWER PLANT

  • Sungkon Moon;Sangwon Han;Myoungwon Kang
    • International conference on construction engineering and project management
    • /
    • 2011.02a
    • /
    • pp.66-73
    • /
    • 2011
  • With rapid industrialization, electric power consumption has been increasing every year in Korea and in other countries. The provision of additional power stations to produce more electricity is one possible response to this steady increase in consumption. Another alternative is to improve the efficiency of existing stations through timely and effective maintenance works. Since the construction of a new power plant involves a large amount of capital as well as difficulties in the selection of sites, the improvement of existing power stations' efficiencies is often a preferred solution. Therefore, this paper focuses on maintenance project management to address this issue. Among several types of maintenance works, this paper concentrates on planned outage maintenance (POM). This focus arises from the critical impact of POM on other maintenance work, as well as the entire process of electricity production. Unlike other maintenance work, POM is done on the basis of mid and long-term plans. In addition, only POM works are conducted during the outage of all power plants. To evaluate the efficiency of POM works, budget data relating to 164 POM projects between 2001 and 2008 was collected from 7 sites in South Korea. Data envelopment analysis (DEA) was selected as a methodology for evaluation. From this analysis, comparative study was used to determine the categories of projects that had performed well, and those with the most optimized budget structures. Moreover, through discussion with industry, this research develops a feasible proposed method by which to enhance the efficiency of POM projects.

  • PDF

OVERALL LINK ANALYSIS ON HRIT AND LRIT IN COMS

  • Park Durk-Jong;Hyun Dae-Wan;Kang Chi-Ho;Ahn Sang-Il;Kim Eun-Kyu
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.98-100
    • /
    • 2005
  • This paper describes link analysis on the processed data, HRIT (High Rate Information Transmission) and LRIT (Low Rate Information Transmission), for the preliminary design of interface between COMS (Communication, Ocean and Meteorological Satellite) and ground station. At the MODAC (MeteorologicaVOcean Data Application Center), the processed data are transmitted to user station via COMS with normalization and calibration by pre-processing of MI (Meteorological Imager) data. Due to consider satellite as radio relay, overall analysis containing uplink and downlink is needed. Specific link parameters can be obtained with using the outcomes of SRR (System Requirement Review) which was held on 13-14 June 2005, in Toulouse. From the relation between overall link margin and output power of HPA (High Power Amplifier) of MODAC, it is shown that even though the minimum power related with COMS receiving power range is transmitted at MODAC, the obtained link margin of HRIT could be above 3 dB at user station which antenna elevation angle is 10 degree.

  • PDF

A Study on the Reliability Prediction and Lifetime of the Electrolytic Condenser for EMU Inverter (전동차 인버터 구동용 전해콘덴서의 신뢰도예측과 수명 연구)

  • Han, Jae-Hyun;Bae, Chang-Han;Koo, Jeong-Seo
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.1
    • /
    • pp.7-14
    • /
    • 2014
  • Inverter module, which feeds the converted power to the traction motor for EMU. Consists of the power semiconductors with their gate drive unit(GDU)s and the control computer for driving, voltage, current and speed controls. Electrolytic condenser, connected to the gate drive unit and a core component to drive the power semiconductor, has problems such as reduction in lifetime and malfunction caused by electrical and mechanical characteristic changes from heat generation during high speed switching for generation of stable power. In this study, To check the service life of electrolytic condenser, the test was carried out in two ways. First, In the case of accelerated life testing of condenser, the Arrhenius model is a way of life testing. Another way is to analyze the reliability of the failure data by the method of parametric data analysis. Eventually, life time by accelerated life test than a method of failure data analysis(Weibull distribution) was found to be slightly larger output.

A Study on the Learning GUI for the Load Flow of Power System (전력조류계산을 위한 학습용GUI에 관한 연구)

  • Lee, Hee-Yeong
    • Proceedings of the KIEE Conference
    • /
    • 2004.07e
    • /
    • pp.27-29
    • /
    • 2004
  • This paper presents improved teaching and learning Gill for easily analysis tool of load flow of power system. This GUI includes not only contingency analysis function, but also calculating power loss from transmission line flow. The Gill is friendly for study for power system operation and control because picture provide a better visualizing of relationships between input parameters and effect than a tabula type result. This Gill enables topology and the output data of load flow for line outages to be shown on same picture page. Users can input the system data for power flow on the the picture and can easily see the the result diagram of bus voltage, bus power, line flow. It is also observe the effects of different types of variation of tap, shunt capacitor, loads level, line outages. Proposed Gill has been studied on the Ward-Hale 6-Bus system.

  • PDF

A study on the energy saving with load characteristic pattern analysis in Electric railway system (전기철도의 부하특성별 패턴 분석을 통한 에너지 절감방안 연구)

  • Jeon, Yong-Joo;Lee, You-Kyung;Lee, Sung-Uk
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1079-1080
    • /
    • 2006
  • This paper presents the methods to save energy by using load consumption pattern analysis. Base on the substation annual power usage data, the characteristic of the substation power consumption have investigated. With this investigation effective electrical billing condition and the control target load has been determined. Most of power usage comes from the motor car, so power system and load table of motor car were reviewed. And in the metropolitan area the peak power consumption occurs at summer or winter rush hours because of its typical characteristics. From this data control point of time are determined. Through the whole study the methode to control the power Peak consumption are proposed and prototype was designed.

  • PDF

A Study on The Design of Network and Database Structure of The Integrated System for Power System Operational Planning and Analysis (전력수급계획 및 운용해석 종합시스템을 위한 네트워크 및 데이터베이스구조 설계에 관한 연구)

  • Ahn, Yang-Keun;Park, Si-Woo;Nam, Jae-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1009-1011
    • /
    • 1998
  • This paper presents a design of network and database structure of the integrated system for power system operational planning and analysis that will be more economical and stable of power system operation. An alias of this system is Highly Integrated Total Energy System(HITES). The Client/server model of HITES is designed as a remote data management model. The input/output-type of application programs and Oracle server is standardized. The separated user-databases from main-database strengthen security of HITES. It is plan to do that tables and relationships are defined by database designs. The connection of application program and DBMS of HITES will be tested through database design and data construction.

  • PDF

Demonstration of EPRI CHECWORKS Code to Predict FAC Wear of Secondary System Pipings of a Nuclear Power Plant

  • Lee, Sung-Ho;Seong Jegarl;Chung, Han-Sub
    • Nuclear Engineering and Technology
    • /
    • v.31 no.4
    • /
    • pp.375-384
    • /
    • 1999
  • The credibility of CHECWORKS FAC model analysis was evaluated for plant application in a model plant chosen for demonstration. The operation condition at each pipe component was defined before the wear rate analysis by plant data base, water chemistry analysis, and network flow analysis. The predicted wear was compared with the measured wear for 57 sample components selected from 43 susceptible line groups analysed. The inspected 57 locations represent components of highest predicted wear in each line group. Both absolute value and relative ranking comparisons indicated reasonable correlations between the predicted and the measured values. Four components showed much higher measured wear rates than the predicted ones in the feed water train from main feed water pump discharge to steam generator, probably due to high hydrazine concentration operation the effect of which had not been incorporated into the CHECWORKS model. The measured wear was higher than the predicted one consistently for components with least susceptibility to FAC. It is believed that the conservatism maintained during UT data analysis dominated the measurement accuracy. A great deal of enhancement is anticipated over the current plant pipe management program when a comprehensive plant pipe management program is implemented based on the model analysis.

  • PDF

Design of Power Efficient Waveforms for Long Range Air-to-Air Data Links (장거리 공대공 데이터링크를 위한 저전력 웨이브폼 설계)

  • Haeuk Lee;Je Heo;Gijung Yang;Taehee Lim;Hyukjun Oh
    • Journal of Advanced Navigation Technology
    • /
    • v.28 no.2
    • /
    • pp.250-253
    • /
    • 2024
  • This paper proposes a low-power waveform for a long-range air-to-air data link. In the case of an air-to-air data link, data communication is performed in the air and high Doppler shift may occur depending on the flight speed, so a waveform based on the non-coherent method is suitable. In addition, since it is mounted on an aircraft, it must have low power characteristics. This paper proposes a waveform that combines a modulation technique based on frequency modulation and pulse position modulation that can turn on/off the transmission signal. As a result of the performance analysis, it was shown that the performance was suitable for air-to-air operation while showing low power characteristics.