• 제목/요약/키워드: Power control

검색결과 18,395건 처리시간 0.049초

Digital Control of an AC/DC Converter using the Power Balance Control Technique with Average Output Voltage Measurement

  • Wisutmetheekorn, Pisit;Chunkag, Viboon
    • Journal of Power Electronics
    • /
    • 제12권1호
    • /
    • pp.88-97
    • /
    • 2012
  • This paper presents a method for the digital control of a high power factor AC/DC converter employing the power balance control technique to achieve a fast response of the output voltage control. To avoid the effects of an output voltage ripple in the voltage control loop, the average output voltage is sampled and used as a feedback signal for the output voltage controller. The proposed control technique was verified by simulations using MATLAB/Simulink and its implementation was realized by a dsPIC30F4011 digital signal processor to control a CUK topology AC/DC converter with a 48V output voltage and a 250 W output power. The experimental results agree with the simulation results. The proposed control technique achieves a fast transient response with a lower line current distortion than is achieved when using a conventional proportional-integral controller and the power balance control technique with the conventional sampling method.

An Efficient Power Control Algorithm for Satellite Communications Systems with ATC

  • Kim, Byung-Gi;Ryoo, Sang-Jin;Hwang, In-Tae
    • Journal of information and communication convergence engineering
    • /
    • 제6권2호
    • /
    • pp.129-133
    • /
    • 2008
  • In this paper, modified power control algorithms are proposed for a satellite mobile communications system with ATC (ancillary terrestrial component). In order to increase system capacity and reduce the transmitting power of the user's equipment, we propose the modified power control scheme consisting of the modified closed-loop and open-loop power control. The modified CLPC (closed-loop power control) algorithm, combining the delay compensation algorithms and pilot diversity, is mainly applied to the ATC link in urban areas because it is more suitable to the short RTD (round-trip delay). In the case of rural areas where ATCs are not deployed or a signal is not received from ATCs, combining monitoring transmitting power equipment and OLPC (open-loop power control) algorithms using an efficient pilot diversity is mainly applied to the link between the user's equipment and the satellite. Two power control algorithms are applied equally to the boundary areas where two kinds of signals are received in order to ensure coverage continuity. The simulation results show that the modified power control scheme has good performance compared to conventional power control schemes in a GEO (geostationary earth orbit) satellite system with ATC.

A Power Control Scheme of a Fuel Cell Hybrid Power Source

  • 송유진;한수빈;박석인;정학근;정봉만;김규덕;유승원
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 추계학술대회 논문집
    • /
    • pp.183-187
    • /
    • 2008
  • This paper describes a power control scheme to improve the performance of a fuel cell battery hybrid power source for residential application. The proposed power control scheme includes a power control strategy to control the power flow of the fuel cell hybrid power system and a digital control technique for a front-end dc-dc converter of the fuel cell. The power control strategy enables the fuel cell to operate within the high efficiency region defined by the polarization curve and efficiency curve of the fuel cell. A dual boost converter with digital control is applied as a front-end dc-dc converter to control the fuel cell output power. The digital control technique of the converter employs a moving-average digital filter into its voltage feedback loop to cancel the low frequency harmonic current drawn from the fuel cell and then limits the fuel cell output current to a current limit using a predictive current limiter to keep the fuel cell operation within the high efficiency region as well as to minimize the fuel cell oxygen starvation.

  • PDF

Supplementary Control of Conventional Coordinated Control for 1000 MW Ultra-supercritical Thermal Power Plant using Dynamic Matrix Control

  • Lee, Youngjun;Yoo, Euiyeon;Lee, Taehyun;Moon, Un-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.97-104
    • /
    • 2018
  • This paper proposes supplementary control of conventional coordinated control of a power plant which directly affects network frequency. The supplementary control with dynamic matrix control is applied for 1000 MW power plant with ultra-supercritical (USC) once-through boiler. The supplementary control signal is added to the boiler feedforward signal in the existing coordinated control logic. Therefore, it is a very practical structure that can maintain the existing multi-loop control system. This supplementary controller uses the step response model for the power plant system, and on-line optimization is performed at every sampling step. The simulation results demonstrate the effectiveness of the proposed supplementary control in a wide operating range of a practical 1000 MW USC power plant simulator. These results can contribute the stable operation of power system frequency.

순시전력 제어 이론을 이용한 유/무효전력의 독립제어에 관한 연구 (A Study on the Decoupled Control of the Active and Reactive Power using Instantaneous Power Control Theory)

  • 김응상;김지원;김영철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권6호
    • /
    • pp.678-682
    • /
    • 1999
  • In this paper, we propose the algorithm which can control active power and reactive power independently in Battery Energy Storage System. The proposed algorithm is based on the instantaneous power theory that the inner product of the voltage vector and current vector represents the active power and the cross product of those represents the reactive power, and it can control active power and reactive power independently. To verify the validity of the proposed algorithm, we make model of the real power system in th KERI and simulate this algorithm. As a result of this simulation, we verified that the proposed algorithm can control active power and reactive power independently.

  • PDF

Smoothing Output Power Variations of Isolated Utility Connected Multiple PV Systems by Coordinated Control

  • Datta, Manoj;Senjyu, Tomonobu;Yona, Atsushi;Sekine, Hideomi;Funabashi, Toshihisa
    • Journal of Power Electronics
    • /
    • 제9권2호
    • /
    • pp.320-333
    • /
    • 2009
  • A Photovoltaic (PV) system's power output varies with the change of climate. Frequency deviations, tie line voltage swings are caused by the varying PV power when large PV power from several PV systems is fed in the utility. In this paper, to overcome these problems, a simple coordinated control method for smoothing the variations of combined PV power from multiple PV systems is proposed. Here, output power command is formed in two steps: central and local. Fuzzy control is used to produce the central smoothing output power command considering insolation, variance of insolation and absolute average of frequency deviation. In local step, a simple coordination is kept between the central power command and the local power commands by producing a common tuning factor. Power converters are used to achieve the same output power as local command power employing PI control law for each of the PV generation systems. The proposed method is compared with the method where conventional Maximum Power Point Tracking (MPPT) control is used for each of the PV systems. Simulation results show that the proposed method is effective for smoothing the output power variations and feasible to reduce the frequency deviations of the power utility.

3차원 전류좌표계 해석법에 의한 DSP 전력분석 제어장치에 관한 연구 (A study on DSP based power analyzing and control system by analysis of 3-dimensional space current co-ordinates)

  • 임영철;정영국;나석환;최찬학;장영학;양승학
    • 대한전기학회논문지
    • /
    • 제45권4호
    • /
    • pp.543-552
    • /
    • 1996
  • The goal of this paper is to developed a DSP based power analyzing and control system by 3-Dimensional (3-D) space current co-ordinates. A developed system is made up of 486-PC and DSP (Digital Signal Processor) board, Active Power Filter, Non-linear thyristor load, and Power analyzing and control program for Windows. Power is analyzed using signal processing techniques based on the correlation between voltage and current waveforms. Since power analysis algorithm is performed by DSP, power analysis is achieved in real-time even under highly dynamic nonlinear loading conditions. Combining control algorithm with power analysis algorithm is performed by DSP, power analysis is achieved in real-time even under highly dynamic nonlinear loading conditions. Combining control algorithm with power analysis algorithm, flexibility of the proposed system which has both power analysis mode and control mode, is greatly enhanced. Non-active power generated while speed of induction motor is controlled by modulating firing angle of thyristor converter, is compensated by Active Power Filter for verifying a developed system. Power analysis results, before/after compensation, are numerically obtained and evaluated. From these results, various graphic screens for time/frequency/3-D current co-ordinate system are displayed on PC. By real-time analysis of power using a developed system, power quality is evaluated, and compared with that of conventional current co-ordinate system. (author). refs., figs. tabs.

  • PDF

전력선통신을 이용한 소규모 주택용 맞춤형 전력피크 제어시스템 개발 (Development of Adaptive Home Power Peak-Cut Control System Using Power Line Communication)

  • 김상동;박지호;김동완
    • 전기학회논문지
    • /
    • 제65권1호
    • /
    • pp.219-226
    • /
    • 2016
  • In this paper, adaptive home power peak-cut control system is developed using PLC. The developed scheme provides monitoring of power usage, power peak-cut control and additional function. In test bed, zone is presented by bedroom, living room, kitchen and bathroom. And individual load is presented by lighting, heater and fan in zone. In developed scheme, zone control is implemented by single PLC modem. And individual load control is implemented by key-map table. In addition, power peak-cut control system S/W, which can perform setting of power peak, power peak-cut control and monitoring of power usage.

Load Test Simulator Development for Steam Turbine-Generator System of Nuclear Power Plant

  • Jeong, Chang-Ki;Kim, Jong-An;Kim, Byung-Chul;Choi, In-Kyu;Woo, Joo-Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1384-1386
    • /
    • 2005
  • This paper focuses on development of load test simulator of a steam turbine-generator in a nuclear power plant. When load is taken off from electrical power network, it is very difficult to effectively control the steam flow to turbine of the nuclear turbine-generator, because of disturbances, such as electrical load and network unbalance on electrical network. Up to the present time, the conventional control system has been used for the load control on nuclear steam generator, owing to the easy control algorithms and the advantage which have been proven on the nuclear power plant. However, since there are problems with stability control during low power and start-up, only a highly experienced operator can operate during those procedures. Also, a great deal of time and an expensive simulator is needed for the training of an operator. The KEPRI is developed simulator for 600MW nuclear power plant to take a test of generator load rejection, throttle valve, and turbine load control. Total load test is implemented before start up.

  • PDF

부하제어 기능을 갖는 디지털형 전동기제어반의 설계 및 구현 (Design and Implementation of Digital Motor Control Center Including Load Control Function)

  • 우천희;강신준;이덕규;구영모;김학배;이성환
    • 제어로봇시스템학회논문지
    • /
    • 제5권7호
    • /
    • pp.868-875
    • /
    • 1999
  • In this paper, digital motor control center using protection relay is developed in order to protect power systems by means of timely fault detection and diagnosis during operation for induction motor which have various load environments and capacities in power systems. Digital motor control center is employed by power supervisory control systems without separate remote terminal unit and transducers adding communicational ability. Also we develope a maximum demand controller to control the load effectively at peak status and a power factor controller to minimize real power losses and improve the power factor. Therefore, when using the developed controller, real time computation is possible by loading DSP in hardware and applying real-time kernel which can convert each algorithm to task module.

  • PDF