• 제목/요약/키워드: Power compensator

검색결과 609건 처리시간 0.027초

Design of Voltage Unbalance Compensator in Cascaded H-bridge Multilevel STATCOM with Unbalanced Load (불평형 부하를 가지는 Cascaded H-bridge Multilevel STATCOM에서 전압불평형 보상기의 설계)

  • Kim, Tae-Hyeong;Kwon, Byung-Ki;Jung, Seung-Ki
    • Proceedings of the KIPE Conference
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.128-129
    • /
    • 2013
  • 본 논문에서는 전기로 부하에서 발생하는 무효전력 성분과 역상분 전류를 보상하기 위한 STATCOM(STATic synchronous COMpensator)을 Cascaded Multilevel Converter(CMC)로 구성하는 경우 역상분 전류 보상시에 발생하는 직류전압의 불평형을 보상하기 위한 방법을 제안하고, 이를 시뮬레이터를 통해 검증하였다.

  • PDF

Analysis of Hydraulic-Pneumatic System for Offshore Plant Heave Compensator (해양플랜트용 수직 보상기의 유공압 시스템 해석)

  • Jung, Yong-Gil;Hwang, Sung-Gu;Kim, Gwi-Nam;Yoon, Yung-Hwan;Hyun, Jang-Hwan;Huh, Sun-Chul
    • Journal of Power System Engineering
    • /
    • 제19권1호
    • /
    • pp.76-82
    • /
    • 2015
  • An analysis model is developed using a commercial software 'simulationX' for designing hydraulic-pneumatic system of heave compensator for offshore drilling operations. Reliability verification of the analysis model for the test equipment of 1/5 scale compensator was conducted by comparing test results and simulation results. An analysis of full scale heave compensator is developed on the basis of verified a model. Then, the results of simulation were analyzed to obtain following conclusion. The displacement of crown block about excitation input amplitude (${\pm}3,000mm$) of the steward platform using a 'simulationX' is attenuated under ${\pm}35mm$, and the compensation rate is 98.7%. In this study, goal of a compensation rate is more than 95%. The previously results are satisfied with the objectives of compensation rate.

AC and DC Applications of Induction Generator Excited by Static VAR Compensator

  • Ahmed, Tarek;Nishida, Katsumi;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제4권3호
    • /
    • pp.169-179
    • /
    • 2004
  • This paper presents the steady-state analysis of the three-phase self-excited induction generator (SEIG). The three-phase SEIG with a squirrel cage rotor is driven by a variable-speed prime mover (VSPM) or a constant-speed prime mover (CSPM) such as a wind turbine or a micro gas turbine. Furthermore, a PI closed-loop feedback voltage regulation scheme of the three-phase SEIG driven by a VSPM on the basis of the static VAR compensator (SVC) is designed and evaluated for the stand-alone AC and DC power applications. The simulation and experimental results prove the practical effectiveness of the additional SVC with the PI controller-based feedback loop in terms of its fast responses and high performances

Comparing Impact of STATCOM and SSSC on the Performance of Digital Distance Relay

  • Ghorbani, Amir
    • Journal of Power Electronics
    • /
    • 제11권6호
    • /
    • pp.890-896
    • /
    • 2011
  • In this paper the impact of a SSSC and a STATCOM on the impedance calculated by a distance relay is investigated. Both analytical analysis and simulations are provided. The STATCOM/SSSC control systems are modeled in detail. It is demonstrated that a SSSC has a greater impact on the calculated impedance by an A-G distance relay element. Several scenarios are considered in the simulations like the impact of the fault conditions, the compensator settings, the power system conditions and so on. All the simulations are carried out in MATLAB/Simulink with detailed models of the SSSC and the STATCOM.

Dynamic Voltage Compensator using Series and Shunt Inverters (직.병렬 인버터를 이용한 동적전압보상기)

  • Park, Deok-Hui;Lee, Jun-Gi;Han, Byeong-Mun;So, Yong-Cheol;Kim, Hyeon-U
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • 제48권11호
    • /
    • pp.655-662
    • /
    • 1999
  • This paper describes controller design and simulation-model development of a dynamic voltage compensator using series and shunt inverters. The control system was designed using PI controller and vector relationship between the supply voltage and load voltage. A simulation model with EMTP was developed to analyze performance of the controller and the whole system. The simulation and experiment results confirm that the dynamic compensator can restore the load voltage under the fault of the distribution system, such as single-line-ground fault, three-line-to-ground fault, and line-to-line fault.

  • PDF

Experimental Operation Analysis of Unified Power Flow Controller with Cascaded H-Bridge Modules (다계 H-브리지 모듈로 구성된 UPFC(Unified Power flow Compensator)의 실험적 동작분석)

  • Baek Seung-Tak;Han Byung-Moon;Choo Jin-Boo;Chang Byung-Hoon;Yoon Jong-Su
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • 제54권9호
    • /
    • pp.422-430
    • /
    • 2005
  • This paper describes experimental analysis of UPFC, which is composed of cascaded H-bridge modules and single-phase multi-winding transformers for isolation. The operational characteristic was analyzed through experimental works with a scaled model, and simulation results with PSCAD/EMTDC. The UPFC proposed in this paper can be directly connected to the transmission line without series injection transformers. It has flexibility to expand the operation voltage by increasing the number of H-bridge modules. The analysis results can be utilized to design the actual WFC system applicable for the transmission system.

Static VAR Compensator-based Feedback Control Implementation for Self-Excited Induction Generator Terminal Voltage Regulation Driven by Variable-Speed Prime Mover

  • Ahmed, Tarek;Nishida, Katsumi;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제4권2호
    • /
    • pp.65-76
    • /
    • 2004
  • In this paper, the steady-state analysis of the three-phase self-excited induction generator (SEIG) driven by a variable-speed prime mover (VSPM) such as a wind turbine is presented. The steady-state torque-speed characteristics of the VSPM are considered with the three-phase SEIG equivalent circuit for evaluating the operating performances due to the inductive load variations. Furthermore, a PI closed-loop feedback voltage regulation scheme based on the static VAR compensator (SVC) for the three-phase SEIG driven by the VSPM is designed and considered for the wind power generation conditioner. The simulation and experimental results prove the practical effectiveness of the additional SVC with the PI controller-based feedback loop in terms of fast response and high performances.

Speed Sensorless Control for Interior Permanent Magnet Synchronous Motor based on an Instantaneous Reactive Power and a Fuzzy PI Compensator (순시무효전력과 퍼이 이득 보상기를 이용한 IPMSM의 속도 센서리스 제어)

  • Kang, Hyoung-Seok;Shin, Jae-Hwa;You, Wan-Sik;Kang, Min-Hyoung;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.173-174
    • /
    • 2007
  • In this paper, a new speed sensorless control based on an instantaneous reactive power and a fuzzy PI compensator are proposed for the interior permanent magnet synchronous motor (IPMSM) drives. The conventional fixed gain PI and PID controllers are very sensitive to step change of command speed, parameter variations and load disturbance. Also, to the estimated speeds are compensated by using an instantaneous reactive power in synchronously rotating reference frame. In a fuzzy compensator, the system control parameters are adjusted by a fuzzy rule based system, which is a logical model of the human behavior for process control. The effectiveness of algorithm is confirmed by the experiments.

  • PDF

Stabilization of High-Voltage Static Var Compensator Using Switching Velocity and Temperature Control (스위칭 속도 및 온도 제어를 사용한 고압용 정지형 무효전력 보상장치의 안정화)

  • Kim, Yong-Tae;Lee, Chang-Seok
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • 제23권2호
    • /
    • pp.107-112
    • /
    • 2013
  • In the paper, velocity controller of switching module and temperature controller for the high-voltage static var compensator are proposed. Because of the continuous increase in demand for electric power, transmission and distribution facilities of power plant are required. There is a bottleneck problem of transportation routes according to new construction and expansion of power transmission facilities. Therefore there are researches to maximize the utilization of existing facilities and to increase transmission capacity without new construction. The previous static var compensator detects voltage of input circuit of power, switches the SCR directly and generates switching noise. The proposed method increases switching velocity and decreases noise using switching control based on the voltage between both sides of SCR. Also the proposed method enhance the stability using realtime temperature control for heating of the system from increase of switching velocity. We experiment the velocity and temperature control of the proposed high-voltage static var compensator in the real environment and verify the performance of the proposed system by applying in the real field.

Electric Arc Furnace Voltage Flicker Mitigation by Applying a Predictive Method with Closed Loop Control of the TCR/FC Compensator

  • Kiyoumarsi, Arash;Ataei, Mohhamad;Hooshmand, Rahmat-Allah;Kolagar, Arash Dehestani
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권1호
    • /
    • pp.116-128
    • /
    • 2010
  • Modeling of the three phase electric arc furnace and its voltage flicker mitigation are the purposes of this paper. For modeling of the electric arc furnace, at first, the arc is modeled by using current-voltage characteristic of a real arc. Then, the arc random characteristic has been taken into account by modulating the ac voltage via a band limited white noise. The electric arc furnace compensation with static VAr compensator, Thyristor Controlled Reactor combined with a Fixed Capacitor bank (TCR/FC), is discussed for closed loop control of the compensator. Instantaneous flicker sensation curves, before and after accomplishing compensation, are measured based on IEC standard. A new method for controlling TCR/FC compensator is proposed. This method is based on applying a predictive approach with closed loop control of the TCR/FC. In this method, by using the previous samples of the load reactive power, the future values of the load reactive power are predicted in order to consider the time delay in the compensator control. Also, in closed loop control, two different approaches are considered. The former is based on voltage regulation at the point of common coupling (PCC) and the later is based on enhancement of power factor at PCC. Finally, in order to show the effectiveness of the proposed methodology, the simulation results are provided.