• Title/Summary/Keyword: Power buoy

Search Result 101, Processing Time 0.022 seconds

A study on design and modeling of a Wave Energy Converter (파력발전기의 에너지 회생을 위한 연구)

  • Yoon, JongIl;Ahn, KyongKwan;Dinh, Quang Truong;Hoang, Huu Tien
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.167.2-167.2
    • /
    • 2011
  • Motions in nature, for example ocean wave, has been playing a significant role for generating electricity production in our modern life. This paper presents an innovative approach for electric power conversion of the vast ocean wave energy. Here, a floating-buoy wave energy converter (WEC) using hydrostatic transmission (HST), which is shortened as HSTWEC, is proposed and designed to enhance the wave energy harvesting task during all wave fluctuations. In this HSTWEC structure, the power take-off system (PTO) is a combination of the designed HST circuit and an electric generator to convert mechanical energy generated by ocean wave into electrical energy. Several design concepts of the HSTWEC have been considered in this study for an adequate investigation. Modeling and simulations using MATLAB/Simulink and AMESim are then carried out to evaluate these design concepts to find out the best solution. In addition, an adaptive controller is designed for improving the HSTWEC performance. The effectiveness of the proposed HSTWEC control system is finally proved by numerical simulations.

  • PDF

Analysis of Wave Load and Mooring System for Ocean Monitoring Facilities - About an estimation method for horizontal force of circular pile in sand - (해상관측시설을 위한 파랑하중과 계류계 해석 -모래중에 뭍힌 원형파일의 수평력 추정방법을 중심으로-)

  • Yoon Gil Su;Kim Yong Jig;Kim Dong Joon;Kang Sin Young
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.1 no.1
    • /
    • pp.102-111
    • /
    • 1998
  • Ocean monitoring facilities are divided into two types, fixed type and floating type. This paper deals with wane load calculation and mooring system for a floating monitoring facility. Wave load and drift forces are calculated for an example case of floating monitoring buoy To enlarge holding power of anchor, circular pile model test was performed. A program for horizontal force of circular pile in sand was made and the calculated result showed fairy good agreement with the result of model test. It is expected that this method will provide good estimation for the holding power of the prototype of circular pile anchor which is relied upon SCUBA activity for installation.

  • PDF

Interaction Analysis on Deployment of Multiple Wave Energy Converters in a Floating Hybrid Power Generation Platform (부유식 복합발전 플랫폼내의 다수 파력발전기 배치를 위한 상호작용 해석)

  • Lee, Hyebin;Cho, Il Hyoung;Kim, Kyong-Hwan;Hong, Keyyong
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.19 no.3
    • /
    • pp.185-193
    • /
    • 2016
  • In this study, the present deployment of the multiple wave energy converters (WECs) in a floating wind-wave hybrid power generation platform was estimated considering the interaction effect among WEC buoys. The interaction processes of multiple buoys were very complex, since scattered and radiated waves from each buoy affected the others in the array. The interaction analysis of the diffraction and radiation problem by the array of WECs was applied by matched eigenfunction expansion method (MEEM). The analytical solutions were compared with the results of numerical calculation based on WAMIT. The overall performance of 24 WECs installed in the hybrid power generation platform was evaluated by the q-factor representing the interaction effect among buoys.

Development of monitoring system to prevent inflow of marine life into the nuclear power plant (해양생물의 원전 취수구 유입 방지를 위한 모니터링 시스템 개발)

  • Tae-Jong KANG;Eun-Bi MIN;Joong-Ro SHIN;Doo-Jin HWANG
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.60 no.3
    • /
    • pp.277-289
    • /
    • 2024
  • Climate change has led to a significant increase in jellyfish populations globally, causing various problems. For power plants that use nearby seawater for cooling, the intrusion of jellyfish into intake systems can block the flow, leading to reduced output or even shutdowns. This issue is compounded by other small marine organisms like shrimp and salps, making it urgent to develop solutions to prevent their intrusion. This study addressed the problem using the BioSonics DT-X 120 kHz scientific fish finder to conduct preliminary tank experiments. We also deployed underwater acoustic and camera buoys around the intake of nuclear power plant, utilizing a bidirectional communication system between sea and land to collect data. Data collection took place from July 31, 2023 to August 1, 2023. While harmful organisms such as jellyfish and salps were not detected, we successfully gathered acoustic data on small fish measuring backscattering strength (SV). Analysis showed that fish schools were more prominent in the evening than during the day. The highest fish distribution was observed at 3:30 AM on July 31 with an SV of -44.8 dB while the lowest was at 12:30 PM on the same day with an SV of -63.4 dB. Additionally, a solar-powered system was used to enable real-time data acquisition from sea buoys with smooth communication between the land server and the offshore buoy located 1.8 km away. This research developed an acoustic-based monitoring system for detecting harmful organisms around the intake and provided foundational data for preventing marine organism intrusion and planning effective measures.

Impact of High-Resolution Sea Surface Temperatures on the Simulated Wind Resources in the Southeastern Coast of the Korean Peninsula (고해상도 해수면온도자료가 한반도 남동해안 풍력자원 수치모의에 미치는 영향)

  • Lee, Hwa-Woon;Cha, Yeong-Min;Lee, Soon-Hwan;Kim, Dong-Hyeok
    • Journal of Environmental Science International
    • /
    • v.19 no.2
    • /
    • pp.171-184
    • /
    • 2010
  • Accurate simulation of the meteorological field is very important to assess the wind resources. Some researchers showed that sea surface temperature (SST) plays a leading role on the local meterological simulation. New Generation Sea Surface Temperature (NGSST), Operational Sea Surface Temperature and Sea Ice Analysis (OSTIA), and Real-Time Global Sea Surface Temperature (RTG SST) have different spatial distribution near the coast and OSTIA shows the best accuracy compared with buoy data in the southeastern coast of the Korean Peninsula. Those SST products are used to initialize the Weather Research and Forecasting (WRF) Model for November 13-23 2008. The simulation of OSTIA shows better result in comparison with NGSST and RTG SST. NGSST shows a large difference with OSTIA in horizontal and vertical wind fields during the weak synoptic condition, but wind power density shows a large difference during strong synoptic condition. RTG SST shows the similar patterns but smaller the magnitude and the extent.

Static and dynamic mooring analysis - Stability of floating production storage and offloading (FPSO) risers for extreme environmental conditions

  • Rho, Yu-Ho;Kim, Kookhyun;Jo, Chul-Hee;Kim, Do-Youb
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.5 no.2
    • /
    • pp.179-187
    • /
    • 2013
  • Floating production storage and offloading (FPSO) facilities are used at most of the offshore oil fields worldwide. FPSO usage is expected to grow as oil fields move to deeper water, thus requiring the reliability and stability of mooring wires and risers in extreme environmental conditions. Except for the case of predictable attack angles of external loadings, FPSO facilities with turret single point mooring (SPM) systems are in general use. There are two types of turret systems: permanent systems and disconnectable turret mooring systems. Extreme environment criteria for permanent moorings are usually based on a 100-year return period event. It is common to use two or three environments including the 100-year wave with associated wind and current, and the 100-year wind with associated waves and current. When fitted with a disconnectable turret mooring system, FPSOs can be used in areas where it is desirable to remove the production unit from the field temporarily to prevent exposure to extreme events such as cyclones or large icebergs. Static and dynamic mooring analyses were performed to evaluate the stability of a spider buoy after disconnection from a turret during cyclone environmental conditions.

Quality Enhancement of MIROS Wave Radar Data at Ieodo Ocean Research Station Using ANN

  • Donghyun Park;Kideok Do;Miyoung Yun;Jin-Yong Jeong
    • Journal of Ocean Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.103-114
    • /
    • 2024
  • Remote sensing wave observation data are crucial when analyzing ocean waves, the main external force of coastal disasters. Nevertheless, it has limitations in accuracy when used in low-wind environments. Therefore, this study collected the raw data from MIROS Wave and Current Radar (MWR) and wave radar at the Ieodo Ocean Research Station (IORS) and applied the optimal filter by combining filters provided by MIROS software. The data were validated by a comparison with South Jeju ocean buoy data. The results showed it maintained accuracy for significant wave height, but errors were observed in significant wave periods and extreme waves. Hence, this study used an artificial neural network (ANN) to improve these errors. The ANN was generalized by separating the data into training and test datasets through stratified sampling, and the optimal model structure was derived by adjusting the hyperparameters. The application of ANN effectively improved the accuracy in significant wave periods and high wave conditions. Consequently, this study reproduced past wave data by enhancing the reliability of the MWR, contributing to understanding wave generation and propagation in storm conditions, and improving the accuracy of wave prediction. On the other hand, errors persisted under high wave conditions because of wave shadow effects, necessitating more data collection and future research.

Design of Multi-channel Anti-Fouling System for Marine Traffic Facilities (해양교통시설물용 다채널 AFS 설계)

  • Oh, Jin-Seok;Kuak, Jun-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.5
    • /
    • pp.661-666
    • /
    • 2011
  • Recently, there are active research activities regarding to power systems of marine traffic facilities using a hybrid generation system which includes a photovoltaic generation system and a wave power generation system. However, when the marine traffic system is operated on a maritime environment for a substantial period of time, it was reported that the shellfish was adhered inside the water column. To tackle this problem, researches on the AFS (Anti-Fouling System) are on the progress. However, use of the single channel AFS resulted in frequent replacement of anode. Thus, the paper proposes a multi-channel method on AFS and experiments have been taken place correspondently. To improve the reliability of the experiment, the melting anode result was applied to our simulation program. The outcome of the simulation illustrates that the proposed multi-channel AFS's anode in the buoy have been ionized equally.

Study of Stability for Armor Weight of Stand-alone Caisson at Yongsu Wave Power Plant (용수 파력발전소 사례에서 독립 케이슨의 피복석 안정성 연구)

  • Kim, Gunwoo
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.31 no.6
    • /
    • pp.478-484
    • /
    • 2019
  • The submarine cable for Yongsu wave power plant was cut in 2014 winter. This study investigated the probability of high-wave occurrence exceeding the 50-year return period and the underestimation of armor unit weight used to protect the cable. The observation data from KMA buoy and the hindcast wave data were reviewed to determine the return period of wave height during the winter. In order to investigate the armor unit weight of cable-protection, we calculated the required weight of armor unit using not only Design Standard for Harbor and Fishery Port, but also the previous researches for the wave with large incident angle. As a result, it appeared that the high wave exceeding the 50-year return period did not occur during the winter of 2014 and the armor unit weight of the cable protection was not sufficient to sustain the obliquely incident wave, which induced the cable protection failure.

PCB Pattern Antenna of 920 MHz Band for Marine IoT Services (해양 IoT 서비스를 위한 920 MHz 대역의 PCB 패턴 안테나)

  • Lee, Seong-Real
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.5
    • /
    • pp.430-436
    • /
    • 2019
  • It is needed to develop an antenna with features of subminiature, light weight and multi-band operation for the variaty services in maritime and industrial fields. The PCB pattern antenna is one of the appropreiate antennas solving these requirements. In this research, the design and fabrication of the PCB pattern antenna operating on the single band of 920 MHz are investigated. The final goal is that the development of the dual band PCB pattern antenna operating on 260 MHz and 920 MHz, which is based on the proposed antenna. It is evident that the performance in the frequencies of 902 MHz, 915 MHz and 928 MHz among of 920 MHz ISM band is better than that in other frequencies. It is also confirmed that the differences of the voltage standing wave ratio, return loss, gain and efficiency between three frequencies are less than 5%. It is expected that the development of communication link of 5-10 km is possible when the induced results are applied into the low power wide area (LPWA) network desinged by the rule of -30 dB sensitivity.