• Title/Summary/Keyword: Power angle

Search Result 2,371, Processing Time 0.026 seconds

Power System Rotor Angle Stability Improvement via Coordinated Design of AVR, PSS2B, and TCSC-Based Damping Controller

  • Jannati, Jamil;Yazdaninejadi, Amin;Nazarpour, Daryush
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.6
    • /
    • pp.341-350
    • /
    • 2016
  • The current study is dedicated to design a novel coordinated controller to effectively increase power system rotor angle stability. In doing so, the coordinated design of an AVR (automatic voltage regulator), PSS2B, and TCSC (thyristor controlled series capacitor)-based POD (power oscillation damping) controller is proposed. Although the recently employed coordination between a CPSS (conventional power system stabilizer) and a TCSC-based POD controller has been shown to improve power system damping characteristics, neglecting the negative impact of existing high-gain AVR on the damping torque by considering its parameters as given values, may reduce the effectiveness of a CPSS-POD controller. Thus, using a technologically viable stabilizer such as PSS2B rather than the CPSS in a coordinated scheme with an AVR and POD controller can constitute a well-established design with a structure that as a high potential to significantly improve the rotor angle stability. The design procedure is formulated as an optimization problem in which the ITSE (integral of time multiplied squared error) performance index as an objective function is minimized by employing an IPSO (improved particle swarm optimization) algorithm to tune adjustable parameters. The robustness of the coordinated designs is guaranteed by concurrently considering some operating conditions in the optimization process. To evaluate the performance of the proposed controllers, eigenvalue analysis and time domain simulations were performed for different operating points and perturbations simulated on 2A4M (two-area four-machine) power systems in MATLAB/Simulink. The results reveal that surpassing improvement in damping of oscillations is achieved in comparison with the CPSS-TCSC coordination.

On discrete nonlinear self-tuning control

  • Mohler, R.-R.;Rajkumar, V.;Zakrzewski, R.-R.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10b
    • /
    • pp.1659-1663
    • /
    • 1991
  • A new control design methodology is presented here which is based on a nonlinear time-series reference model. It is indicated by highly nonlinear simulations that such designs successfully stabilize troublesome aircraft maneuvers undergoing large changes in angle of attack as well as large electric power transients due to line faults. In both applications, the nonlinear controller was significantly better than the corresponding linear adaptive controller. For the electric power network, a flexible a.c. transmission system (FACTS) with series capacitor power feedback control is studied. A bilinear auto-regressive moving average (BARMA) reference model is identified from system data and the feedback control manipulated according to a desired reference state. The control is optimized according to a predictive one-step quadratic performance index (J). A similar algorithm is derived for control of rapid changes in aircraft angle of attack over a normally unstable flight regime. In the latter case, however, a generalization of a bilinear time-series model reference includes quadratic and cubic terms in angle of attack. These applications are typical of the numerous plants for which nonlinear adaptive control has the potential to provide significant performance improvements. For aircraft control, significant maneuverability gains can provide safer transportation under large windshear disturbances as well as tactical advantages. For FACTS, there is the potential for significant increase in admissible electric power transmission over available transmission lines along with energy conservation. Electric power systems are inherently nonlinear for significant transient variations from synchronism such as may result for large fault disturbances. In such cases, traditional linear controllers may not stabilize the swing (in rotor angle) without inefficient energy wasting strategies to shed loads, etc. Fortunately, the advent of power electronics (e.g., high-speed thyristors) admits the possibility of adaptive control by means of FACTS. Line admittance manipulation seems to be an effective means to achieve stabilization and high efficiency for such FACTS. This results in parametric (or multiplicative) control of a highly nonlinear plant.

  • PDF

CONTROL OF LASER WELD KEYHOLE DYNAMICS BY POWER MODULATION

  • Cho, Min-Hyun;Dave Farson
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.600-605
    • /
    • 2002
  • The keyhole formed by high energy density laser-material interaction periodically collapses due to surface tension of the molten metal in partial penetration welds. The collapse sometimes traps a void at the bottom of the keyhole, and it remains as welding defects. This phenomenon is seen as one cause of the instability of the keyhole during laser beam welding. Thus, it seems likely that improving the stability of the keyhole can reduce voids and uniform the penetration depth. The goal of this work is to develop techniques for controlling laser weld keyhole dynamics to reduce weld defects such as voids and inconsistent penetration. Statistical analysis of the penetration depth signals in glycerin determined that keyhole dynamics are chaotic. The chaotic nature of keyhole fluctuations and the ability of laser power modulation to control them have been demonstrated by high-speed video images of laser welds in glycerin. Additionally, an incident leading beam angle is applied to enhance the stability of the keyhole. The quasi-sinusoidal laser beam power of 400Hz frequency and 15$^{\circ}$ incident leading beam angle were determined to be the optimum parameters for the reduction of voids. Finally, chaos analyses of uncontrolled signals and controlled signals were done to show the effectiveness of modulation on the keyhole dynamics. Three-dimensional phase plots for uncontrolled system and controlled system are produced to demonstrate that the chaotic keyhole dynamics is converted to regular periodic behavior by control methods: power modulation and incident leading beam angle.

  • PDF

Optimal Characteristics of a Long-pulse $CO_2$Laser by Controlling SCR Firing Angle in AC Power Line

  • Noh, Ki-Kyung;Kim, Geun-Yong;Chung, Hyun-Ju;Min, Byoung-Dae;Song, Keun-Ju;Kim, Hee-Je
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.2C no.6
    • /
    • pp.304-308
    • /
    • 2002
  • We demonstrate a simple pulsed $CO_2$ laser with millisecond long pulse duration in a tube at a low pressure of less than 30 Torr. The novel power supply for our laser system switches the voltage of the AC power line (60Hz) directly. The power supply doesn't need elements such as a rectifier bridge, energy-storage capacitors, or a current-limiting resistor in the discharge circuit. To control the laser output power, the pulse repetition rate is adjusted up to 60Hz and the firing angle of SCR(Silicon Controlled Rectifier) gate is varied from 30。 to 150。. A ZCS (Zero Crossing Switch) circuit and a PIC one-chip microprocessor are used to control precisely the gate signal of the SCR. The maximum laser output of 35 W is obtained at a total pressure of 18 Torr, a pulse repetition rate of 60 Hz, and a SCR gate firing angle of 90。 . In addition, the resulting laser pulse width is approximately 3㎳(FWHM). This is a relatively long pulse width, compared with other repetitively pulsed $CO_2$ lasers.

Reduction of Power Consumption for Constant Pressure Control of Variable Swash Plate-type Piston Pump by Varying the Pump Speed (가변 용적형 사판식 피스톤 펌프의 회전 속도 조절에 의한 정압 제어 소비 동력 절감)

  • Kim, J.H.;Hong, Y.S.
    • Journal of Drive and Control
    • /
    • v.11 no.4
    • /
    • pp.53-60
    • /
    • 2014
  • This paper proposes a control scheme to reduce the power consumption of a variable displacement swash-plate type piston pump supplying oil to a valve-controlled hydraulic cylinder at constant pressure. Whenever flow rate demand was absent, the swash plate angle and the pump speed were changed to the minimum values required to compensate for the internal leakage flow. In response to command signals, the pump speed was changed in proportion to the absolute mean value of the speed component for position commands. At the same time, a pressure regulator was activated to maintain constant system pressure by precisely adjusting the pump speed with the swash plate angle fixed at the maximum. The conventional system consisting of a pressure-compensated variable displacement type pump is driven at a constant speed of 1,800rpm. By comparison, computer simulation and experimental results showed that idling power at stand-by status could be reduced by up to 70% by reducing the pump speed from 1,800rpm to 300rpm and the swash plate angle to the minimum.

A Fault Diagnosis and Control Integrated System for an SP-100 Space Reactor (SP-100 우주선 원자로를 위한 고장진단 및 제어 통합 시스템)

  • Na, Man-Gyun;Yang, Heon-Young;Lim, Dong-Hyuk;Lee, Yoon-Joon
    • Proceedings of the KIEE Conference
    • /
    • 2007.10a
    • /
    • pp.231-232
    • /
    • 2007
  • In this paper, a fault diagnosis and control integrated system (FDCIS) was developed to control the thermoelectric (TE) power in the SP-100 space reactor. The objectives of the proposed model predictive control were to minimize both the difference between the predicted TE power and the desired power, and the variation of control drum angle that adjusts the control reactivity. Also, the objectives were subject to maximum and minimum control drum angle and maximum drum angle variation speed. A genetic algorithm was used to optimize the model predictive controller. The model predictive controller was integrated with a fault detection and diagnostics algorithm so that the controller can work properly even under input and output measurement faults. With the presence of faults, the control law was reconfigured using online estimates of the measurements. Simulation results of the proposed controller showed that the TE generator power level controlled by the proposed controller could track the target power level effectively even under measurement faults, satisfying all control constraints.

  • PDF

Modeling and Design of Zero-Voltage-Switching Controller for Wireless Power Transfer Systems Based on Closed-Loop Dominant Pole

  • Chen, Cheng;Zhou, Hong;Deng, Qijun;Hu, Wenshan;Yu, Yanjuan;Lu, Xiaoqing;Lai, Jingang
    • Journal of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.1235-1247
    • /
    • 2019
  • Zero-Voltage-Switching (ZVS) operation for a Wireless Power Transfer (WPT) system can be achieved by designing a ZVS controller. However, the performance of the controller in some industrial applications needs to be designed tightly. This paper introduces a ZVS controller design method for WPT systems. The parameters of the controller are designed according to the desired performance based on the closed loop dominant pole placement method. To describe the dynamic characteristics of the system ZVS angle, a nonlinear dynamic model is deduced and linearized using the small signal linearization method. By analyzing the zero-pole distribution, a low-order equivalent model that facilitates the controller design is obtained. The parameters of the controller are designed by calculating the time constant of the closed-loop dominant poles. A prototype of a WPT system with the designed controller and a five-stage multistage series variable capacitor (MSVC) is built and tested to verify the performance of the controller. The recorded response curves and waveforms show that the designed controller can maintain the ZVS angle at the reference angle with satisfactory control performance.

Numerical Investigation of Performance Characteristics for Cooling Tower Axial Fans with Sweep (스윕을 가진 냉각탑용 축류홴의 성능 특성에 관한 수치해석적 연구)

  • Oh, K.J.
    • Journal of Power System Engineering
    • /
    • v.13 no.4
    • /
    • pp.31-37
    • /
    • 2009
  • The purpose of this numerical study was to investigate performance characteristics for cooling tower axial fans with sweep. Performance data for the fans with various sweep angles were obtained in terms of the setting angle at a constant flow rate. Viscous flow calculations were carried out to obtain Performance data of the total pressure rise and hydraulic efficiency. A solution of the Ffowcs Williams-Hawkings equations was used to calculate the sound pressure level at three times fan diameter away from the fan. The calculated performance data well represented performance characteristics of the cooling tower axial fan. The total pressure rise and hydraulic efficiency at the same setting angle decreased with sweep angle. Sound pressure level slightly decreased for the fan with a sweep angle of 10 degree. No significant effect of the sweep geometry was found on the sound pressure level.

  • PDF

Characteristics of the Lower Limbs Muscular Force on the Angle Variation of Tilting Bed (경사 침대의 각도 변화에 따른 하지 근력 특성)

  • 김경;김성현;정성환;김기범;권대규;홍철운;김남균
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.944-947
    • /
    • 2004
  • The purpose of this study was to identify the characteristics of muscular power by COP(center of pressure) training according to the angle variation of tilting bed. We changed the angles of tilting bed(up-down direction 0$^{\circ}$, 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$ and right-left direction -15$^{\circ}$, 0$^{\circ}$, +15$^{\circ}$) for the correlation between angles and muscular power. And we measured EMG(electormyography) of lower limbs muscle(rectus femoris, biceps femoris, and gastrocnemius, tibialisa anterior) during COP training. COP training was divided by the COP trace training(in all direction) and sine wave trace training(vertical and horizontal direction). As the result, we obtained the improvement effect of COP training and we showed that electromyography(EMG) variations of lower limbs muscle on the angle variations of tilting bed were investigated.

  • PDF

Study on the Temperature Drift Adaptive Compensation Algorithm of a Magneto-Electric Encoder Based on a Simple Neuron

  • Wang, Lei;Hao, Shuang-Hui;Song, Bao-Yu;Hao, Ming-Hui
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1254-1262
    • /
    • 2014
  • Magneto-electric encoders have been widely used in industry and military applications because of their good shock resistance, small volume, and convenient data processing. However, the characteristics of a magneto-electric encoder's signal generator and hall sensor changes minimally with temperature variation. These changes cause an angle drift. The main purpose of this study is to construct the compensation system of a neural network and constantly update weight coefficients of temperature correction by finite iteration calculation so that the angle value modified can approach the angle value at the target temperature. This approach is used in adaptive correction of the angle value.