• Title/Summary/Keyword: Power Window

Search Result 458, Processing Time 0.027 seconds

An Evaluation of Operator's Action Time for Core Cooling Recovery Operation in Nuclear Power Plant (원자력발전소의 노심냉각회복 조치에 대한 운전원 조치시간 평가)

  • Bae, Yeon-Kyoung
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.5
    • /
    • pp.229-234
    • /
    • 2012
  • Operator's action time is evaluated from MAAP4 analysis used in conventional probabilistic safety assessment(PSA) of a nuclear power plant. MAAP4 code which was developed for severe accident analysis is too conservative to perform a realistic PSA. A best-estimate code such as RELAP5/MOD3, MARS has been used to reduce the conservatism of thermal hydraulic analysis. In this study, operator's action time of core cooling recovery operation is evaluated by using the MARS code, which its Fussell-Vessely(F-V) value was evaluated as highly important in a small break loss of coolant(SBLOCA) event and loss of component cooling water(LOCCW) event in previous PSA. The main conclusions were elicited : (1) MARS analysis provides larger time window for operator's action time than MAAP4 analysis and gives the more realistic time window in PSA (2) Sufficient operator's action time can reduce human error probability and core damage frequency in PSA.

A Study on the Control System Implementation of Human Body Nerves Signal (인체 신경신호 제어시스템 구현에 관한 연구)

  • Ko, Duck-Young;Kim, Sung-Gon;Choi, Jong-Ho
    • 전자공학회논문지 IE
    • /
    • v.43 no.1
    • /
    • pp.16-24
    • /
    • 2006
  • This paper is aimed to develope of an integrated BCI(Brain Computer Interface System) that make possible for simultaneous multichannel data process and used extra cellular neural activity from the vestibular system instead of electroencephalogram signals for more precision control. The electrical properties pre-amplifier are 47.6 dB of gain, 0.005 % of distortion at 100 Hz, 12M$\Omega$ of input impedance. Window discriminator used two CPU with difference role to increase processing speed so that sampling frequency was 87 kHz. The designed window discriminator has more not only two times in signal resolution power but also ten times in error discrimination power than commericially available discriminator. The proposed method decreases 100 times in amount of integrated data then BCI system during 100 ms.

The Signal Acquisition Algorithm for Ultra Wide-band Communication Systems (UWB 통신시스템에서 동기 획득 알고리즘)

  • Park, Dae-Heon;Kang, Beom-Jin;Park, Jang-Woo;Cho, Sung-Eon
    • Journal of Advanced Navigation Technology
    • /
    • v.12 no.2
    • /
    • pp.146-153
    • /
    • 2008
  • Due to the extremely short pulse in the Ultra-Wideband (UWB) technology, the accurate synchronization acquisition method is very important for both high data-rate WPAN and low data-rate WPAN. In this paper, we propose the synchronization acquisition algorithm based on two-step signal search method to acquire the synchronization in the UWB multi-path channel. At the first step, the search window is divided by two and the window that has higher power is chosen as a next search window. This operation is repeated until the measure power of the search window is smaller than the threshold value. At the second step, we employ Linear Search algorithm to the search window obtained at the first step for fine search. The proposed algorithm is proved that the synchronization acquisition is faster than the parallel search algorithm and it shows good performance in environment of the SNR extreme changes by the simulation.

  • PDF

Prediction of Lift Performance of Automotive Glass Using Finite Element Analysis (유한요소해석을 통한 자동차용 글라스의 승강성능 예측)

  • Moon, Hyung-Il;Kim, Heon-Young;Choi, Cheon;Lee, In-Heok;Kim, Do-Hyung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.11
    • /
    • pp.1749-1755
    • /
    • 2010
  • The performance of power window system was decided by driving characteristics of the window regulator part and reaction by the glass run. The performance of power window system usually has been predicted by experimental methods. In this paper, an analytical method using the explicit code was suggested to overcome the limit of the experimental methods. The friction coefficient of glass run was obtained by the friction test at various conditions and the Mooney-Rivlin model was used. Also, a mechanism of window regulator consisted of the fast belt system and the slip ring elements. And, we conducted the analysis considering characteristic of a motor and obtained the lifting speed of automotive glass with high reliability

Educational Simulator for Transmission Network Use of System Charge (송전망 이용요금산정을 위한 교육용 시뮬레이터 개발)

  • Kim, H.H.;Song, H.Y.;Lee, C.J.;Park, J.B.;Shin, J.R.
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.201-203
    • /
    • 2006
  • This paper presents a graphical windows-based software for the education and training of the transmission network use of system charge. The developed simulator consist of the main module(MMI,GUI), the power flow module(PF), the power flow tracing module(PFT) and management of usage cost DB module(UCD). Each module has a separate graphical and interactive interfacing window. To have effective education for transmission network use of system charge, the developed simulator are provided with two power system analysis methods. Input data of power system can use the format of PSS/E input data. Also calculation of power flow tracing are provided with four methods such as "Felix Wu","Modified Felix Wu", "DCLF ICRP" and "Reverse MW mile". Results of calculation for usage cost are shown on the window through the table or chart. Therefore user can confirm the detailed differences of results from each calculation method.

  • PDF

A New Peak-Windowing Algorithm with Window-length Adaptation for PAPR Reduction of OFDM Systems (OFDM 시스템의 PAPR 저감을 위한 가변적인 윈도우 크기를 적용한 Peak Windowing 기법)

  • Lee, Sung-Eun;Bang, Keuk-Joon;Park, Myong-Hee;Lee, Young-Soo;Hong, Dae-Sik
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.185-188
    • /
    • 2005
  • This paper proposes a new peak-windowing algorithm with window-length adaptation for peak-to-average power reduction (PAPR) of orthogonal frequency division multiplexing (OFDM) systems. Conventional peak windowing algorithm has advantages, such as moderate system complexity with good spectral shape. However, adjacent peak signals within the length of window functions produce the distortion of signal amplitude since window functions might overap with each other. These undesired characteristics of conventional peak windowing algorithm result in the degradation of BER performance. The proposed algorithm outperforms the conventional one with the aid of window-length adaptation. Simulation results show the efficiency of the proposed algorithm under the environments of WiBro downlink systems.

  • PDF

Thermal Hydraulic Power Analysis of the HYPER Target Beam Window (미임계로 표적빔창의 열수력 해석)

  • Song Min-Geun;Ju Eun-Sun;Choi Jin-Ho;Song Tae-Young;Tak Nam-Il;Park Won-Sok
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.39-42
    • /
    • 2002
  • The nuclear transmutation technology to Incinerate the long lived radioactive nuclides and produce energy during the incineration process is believed to be one or the best solutions. HYPER(${\underline{HY}}brid {\underline{P}}ower {\underline{E}}xtraction {\underline{R}}$eactor)is the accelerator driven transmutation system which is being developed by KAERI(Korea Atomic Energy Research Institute). Lead-bismuth(Pb-Bi) is adopted as a coolant and spallation target material. In this paper, we performed the thermal-hydraulic analysis of HYPER target using the commercial code FLUENT, and also calculated thermal and mechanical stress of the beam window using the commercial code ANSYS. It is found that there is an optimum value for the window diameter and the maximum allowable beam current can be increased to 17.3 mA for the inner diameter of windows, 40 cm. Finally, the other shapes such as uniform or scanned beam were considered. The results of FLUENT calculations show that the uniform type is preferable to the other shapes of the beam in terms of the window and target cooling and the maximum window temperature is lower than that of the parabolic beam by $58 ^{\circ}C$ for the beam current, 13 mA.

  • PDF

The Effect of the Signal Stationarity on the EMG Frequency Analysis (허리 근육의 근전도 신호 안정성이 주파수 분석에 미치는 영향)

  • Cho, Young-Jin;Kim, Jung-Yong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.29 no.2
    • /
    • pp.183-188
    • /
    • 2010
  • The purpose of this study is to investigate the stationarity of the electromyographic signal in various flexion angles, loads, and window sizes, which influence the result of the mean power frequency (MPF) and median frequency (MNF) analysis. Six healthy subjects participated in the experiment. They were tested in the combination of 3-level flexion angles (0 degree, 22.5 degree, 45 degree) and 3-level loads (0Nm, 30Nm, 60Nm). Electromyographic data were collected for 20 seconds during isometric contraction. The stationarity of collected data were analyzed with four different window sizes including 250, 500, 1000 and 2000ms. Two test methods for stationarity such as Reverse Arrangements Test and Modified Reverse Arrangements Test were used. In order to show the effect of nonstationarity, the increasing/decreasing trend of MPF and MNF trend were discussed. In results, the stationarity of the electromyographic signal decreased as flexion angle increased and load decreased while window size decreased based on Reverse Arrangements Test. The highest stationarity was shown at 500 ms window in Modified Reverse Arrangements Test. The inclination of MNF and MPF indicated 3.6-6.3%, 3.8-5.1% discrepancy compared to the result from stationary data.

The Improvement in Signal Integrity of FT-ICR MS (FT-ICR 질량분석기의 신호 충실성 향상)

  • Kim, Seung-Yong;Kim, Seok-Yoon;Kim, Hyun Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.1
    • /
    • pp.201-204
    • /
    • 2011
  • For efficient noise reduction in a Fourier transform ion cyclotron resonance (FT-ICR) mass spectrum, a new algorithm was proposed. The suggested algorithm reduces white and electrical noise, and it improves signal-to-noise ratio. This algorithm has been optimized to reduce the noise more efficiently using the traces of signal level. The algorithm has been efficiently combined with derivative window to improve the resolution as well S/N. Time domain data was corrected for DC voltage interference. $t^n$ window was applied in time domain data to improved the resolution. However, $t^n$ window can improve the signal resolution, it will also increase the noise level in frequency domain. Therefore, newly developed noise reduction algorithm will be applied to make a balance between resolving power and S/N ratio for magnitude mode. The trace algorithm can determine the current data point with several data points (mean, past data, calculated past data). In the current calculations, we assumed data points with S/N ratio more than 3 were considered as signal data points. After the windowing and noise reduction, both resolution and signal-to-noise ratio were improved. This algorithm is applicable more efficiently to frequency dependent noise and large size data.

A New Low Power LFSR Architecture using a Transition Monitoring Window (천이 감시 윈도우를 이용한 새로운 저전력 LFSR 구조)

  • Kim Youbean;Yang Myung-Hoon;Lee Yong;Park Hyuntae;Kang Sungho
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.8 s.338
    • /
    • pp.7-14
    • /
    • 2005
  • This paper presents a new low power BIST TPG scheme. It uses a transition monitoring window (TMW) that is comprised of a transition monitoring window block and a MUX. When random test patterns are generated by an LFSR, transitions of those patterns satisfy pseudo-random gaussian distribution. The Proposed technique represses transitions of patterns using a k-value which is a standard that is obtained from the distribution of U to observe over transitive patterns causing high power dissipation in a scan chain. Experimental results show that the Proposed BIST TPG schemes can reduce scan transition by about $60\%$ without performance loss in ISCAS'89 benchmark circuits that have large number scan inputs.