• Title/Summary/Keyword: Power Vector

Search Result 1,571, Processing Time 0.028 seconds

A Study on the Current-diagram Method for Calculating Induction Motor Characteristics with Adjustable Frequency (가변주파수에 있어서 유도전동기의 특성도식 산정법에 관해서 제1보)

  • Min-Ho Park
    • 전기의세계
    • /
    • v.17 no.3
    • /
    • pp.29-38
    • /
    • 1968
  • The development of the frequency converter using semiconductor enables to easily control the speed of A.C. motors. It is now technically possible and economically feasible to provide them with power at variable frequency, using silicon-controlled-rectifier (or thyristor) inverters. In such a case, if an induction motor is to be operated efficiently over a wide speed range, it must be supplied from a variable-frequency source whose frequency is adjustable over a range similar to that required for the motor speed. It is desired to observe how several characteristics are changed such as primary current, torque-speed, etc. Although the characteristics could be obtained by means of the conventional method, it requires very complicated calculation. It is assumed that the charateristics above are easily investigated by means of current diagram method from variable circuit constants relating to the motor which is designed in rated frequency. In this paper, the results of the study on the current-diagram method and its application are described as follows; (1) In order to discuss the construction of current diagram, the equation of the stator current with adjustable frequency was derived for applying the Current Diagram Method. (2) The radius, the center of the current circle and current vector locus at any desired frequency could be easily determined with the aid of both above mentioned equation and the standard current diagram at reference frequency. (3) This method could be applicable to the various types of Induction Motors, and this paper has dealt with its application to the capacitor, split-phase and 2-phase types of motors.

  • PDF

Design of output feedback variable structure control system with robust properties (출력궤한 가변구조제어게의 강인성 설계)

  • 이기상;임재형;이정동
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.1199-1205
    • /
    • 1993
  • It has been well known that the assumption of full state availability is one of the most important restrictions to the practical realization of VSCS. And several attempts to alleviate the assumption had been made. However, it is not easy to find a positive scheme among them. Recently, an output feedback variable structure control system(OFVSCS) was proposed and the effectiveness of the scheme was validated for the disturbance free systems. The purpose of this study is to propose a robust OFVSCS that have the robust properties against process parameter variations and external distrubances by extending the basic OFVSCS and to evaluate its control performances through power system stabilizer design example. The ROFVSCS is composed of dynamic switching function and output feedback switching control inputs that are constructed by the use of the unknown vector modeling technique. With the proposed scheme, existence of sliding mode is guaranteed and any nonzero bias can be suppressed in the face of disturbances and process parameter variations as far as well-known matching condition is satisfied. Due to the fact that the ROFVSCS is driven by small number of measured informations, the practical application of VSCS for the systems with unmeasurable states and for high order systems that conventional schemes cannot be applied, is possible with the proposed scheme. It is noticeable that the implementation cost of VSCS can be considerably reduced without sacrifice of control performances by adopting ROFVSCS since there is no need measure the states with high measurement cost.

  • PDF

Steering Angle Error Compensation Algorithm Appropriate for Rapidly Moving Sources (빠른 속도로 기동하는 표적 환경에 적합한 조향각 오차 보정기법)

  • 박규태;박도현;이정훈;이균경
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.3
    • /
    • pp.206-213
    • /
    • 2004
  • This paper presents a steering angle error compensation (SAEC) algorithm that is appropriate for rapidly moving sources. The Proposed algorithm utilizes a modal covariance matrix from multiple frequency components instead of the multiple snapshots in a narrowband SAEC, and estimates the steering error by maximizing the wideband WVDR output power using a first-order Taylor series approximation of the modal steering vector in terms of the steering error. As such, the steering error can be compensated with short observation times. Several simulations using artificial and sea trial data are used to demonstrate the Performance of the proposed algorithm.

Supercomputer's Security Issues and Defense: Survey (슈퍼컴퓨터 보안 이슈 및 대책)

  • Hong, Sunghyuck
    • Journal of Digital Convergence
    • /
    • v.11 no.4
    • /
    • pp.215-220
    • /
    • 2013
  • The super computer calls usually as the super computer in case the computing power of the computer is 20 G flops (GFLOPS) or greater. In the past, the computer equipped with the vector processor (the instrument processing the order having the logic operation and maximum value or minimum value besides the common computer instruction) processing the scientific calculation with the super high speed was installed as the super computer. Recently, cyber attack focuses on supercomputer because if it is being infected, then it will affect hundreds of client PC. Therefore, our research paper analyzed super computer security issues and biometric countermeasure to develop the level of security on super computer.

Design of High-Efficiency Full-Bridge Converter and Inverter for ESS (ESS용 고효율 풀브리지 컨버터 및 인버터 설계)

  • Jung, Jae-Hun;Lee, Chang-woo;Choi, Jin-ku
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.685-688
    • /
    • 2015
  • A phase-shift full-bridge converter is widely used conventional converter. If the input power change in the variation of the output voltage, there is a time interval freewheeling according to a duty change. This is a factor of reducing the efficiency. In this paper, we propose a method for improving the efficiency of the converter/inverter systems that require high efficiency in the ESS. The proposed method was used for the duty control for solving the fail problem ZVS(Zero Voltage Switching) in Freewheeling interval. The proposed method was verified by experiments.

  • PDF

Optimization of the design variables of linear motor by FEM (유한요소법에 의한 선형모터의 설계 변수 최적화)

  • Shin, Soo-Hyun;Lee, Sang-Ryong;Jung, Jae-Han
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.7
    • /
    • pp.1232-1240
    • /
    • 2002
  • Recently, linear motors are applied to many small precision products. Thus high generating power with small size is required of it. In order to increase the motor efficiency, the design variables need to be optimized. In this study, Vector Fields FEM software, OPERA-3d, was used for simulating linear motor. The thrust and magnetic flux density at the air-gap center were simulated and compared with the experimental results. Taguchi method was applied to investigate the effects of each variables. As a result, the thickness of conductor and magnet was important for the thrust but the thickness of the yoke. The temperature of the conductor was determined by finding the thermal conductivity that was determined by experimentation. Correlation equation relating to the thrust and temperature was proposed by Latin square and Least Square method. The optimum design variables were determined by correlation equation, and compared with simulation results. According to this analysis, thrust force of linear motor was improved about 7% comparing with conventional model.

Uniform DFT Polyphase Filterbank based DF Method for Frequency Hopping Signal Direction Finding (주파수 도약신호 방탐을 위한 균등 디지털주파수변환 폴리페이즈 필터뱅크 기반 방탐기술)

  • Lee, Young-Jin;Kwon, Hyuk-Ja
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.3
    • /
    • pp.119-128
    • /
    • 2017
  • In this paper, the wideband direction finding algorithm and system design method for short duration signal such as frequency hopping or burst signal is presented. The polyphase filterbank that it is possible for the near perfect reconstruction was used as a pre-processing and in each subband power measurement was performed to determine whether the presence of a signal and finally general direction finding algorithm was performed. In addition, various experiments was performed using Matlab Simulink and collected data from wideband receiver to verification of the proposed algorithm.

Human Action Recognition Bases on Local Action Attributes

  • Zhang, Jing;Lin, Hong;Nie, Weizhi;Chaisorn, Lekha;Wong, Yongkang;Kankanhalli, Mohan S
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1264-1274
    • /
    • 2015
  • Human action recognition received many interest in the computer vision community. Most of the existing methods focus on either construct robust descriptor from the temporal domain, or computational method to exploit the discriminative power of the descriptor. In this paper we explore the idea of using local action attributes to form an action descriptor, where an action is no longer characterized with the motion changes in the temporal domain but the local semantic description of the action. We propose an novel framework where introduces local action attributes to represent an action for the final human action categorization. The local action attributes are defined for each body part which are independent from the global action. The resulting attribute descriptor is used to jointly model human action to achieve robust performance. In addition, we conduct some study on the impact of using body local and global low-level feature for the aforementioned attributes. Experiments on the KTH dataset and the MV-TJU dataset show that our local action attribute based descriptor improve action recognition performance.

Improved Method for Calculating Magnetic Field of Surface-Mounted Permanent Magnet Machines Accounting for Slots and Eccentric Magnet Pole

  • Zhou, Yu;Li, Huaishu;Wang, Wei;Cao, Qing;Zhou, Shi
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1025-1034
    • /
    • 2015
  • This paper presented an improved analytical method for calculating the open-circuit magnetic field in the surface-mounted permanent magnet machines accounting for slots and eccentric magnet pole. Magnetic field produced by radial and parallel permanent magnet is equivalent to that produced by surface current according to equivalent surface-current method of permanent magnet. The model is divided into two types of subdomains. The field solution of each subdomain is obtained by applying the interface and boundary conditions. The magnet field produced by equivalent surface current is superposed according to superposition principle of vector potential. The investigation shows harmonic contents of radial flux density can be reduced a lot by changing eccentric distance of eccentric magnet poles compared with conventional surface-mounted permanent-magnet machines with concentric magnet poles. The FE(finite element) results confirm the validity of the analytical results with the proposed model.

F-V Analysis and STATCOM Installation Method to Replace Constrained Generation (F-V 해석을 이용한 수도권 제약발전 대체를 위한 STATCOM 투입 위치 선정 방안)

  • Noh, Hyeok-Jin;Oh, Seung-Chan;Park, Bohyun;Choi, Jin-San;Lee, Byong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.163-164
    • /
    • 2015
  • LNG복합발전은 수요지 인근에 건설이 가능한 장점이 있어 수도권 인근 발전소 중 상당한 부분을 차지하고 있다. 이러한 LNG 복합발전은 수도권 부하비율 감소에 따라 발전량이 줄어들게 된다. 2018년 계통데이터를 기반으로 수도권의 부하수준이 70%까지 떨어졌을 때, 거의 모든 수도권 복합발전이 정지함을 확인할 수 있다. 이 때, 신가평과 강원을 잇는 765kV급 융통선로의 2회선 상정사고 발생 시 수도권 무효전력 공급원이 줄어들어 전압이 불안정해진다. 이와 같은 상정사고를 대비해 수도권 복합발전 중 일부는 제약운전을 시행해야 한다. 본 논문에서는 제약운전을 하는 수도권 LNG복합발전의 발전량을 대체할 수 있는 대안으로 적절한 위치에 FACTS설비를 투입하고자 한다. FACTS설비를 효율적으로 운전시키기 위해 LNG복합발전의 발전량 감소에 따른 전압변화에 대해 Tangent Vector Component가 가장 큰 수도권 345kV 모선을 선정해 STATCOM을 투입하고 그 결과를 확인한다. 이를 확인하기 위한 방안으로 제약운전을 하는 복합발전의 발전량을 감소시키고 관찰하고자 하는 모선과 거리가 먼 비수도권 발전량을 증가시켜 수급을 맞춘 뒤 전압의 변화를 관찰한다. 이 때, 하나의 계통을 2개의 지역으로 구역화하여 전압을 확인할 수 있는 F-V 해석을 이용한다.

  • PDF