• Title/Summary/Keyword: Power Turbine

Search Result 2,634, Processing Time 0.183 seconds

Experimental Assessment with Wind Turbine Emulator of Variable-Speed Wind Power Generation System using Boost Chopper Circuit of Permanent Magnet Synchronous Generator

  • Tammaruckwattana, Sirichai;Ohyama, Kazuhiro;Yue, Chenxin
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.246-255
    • /
    • 2015
  • This paper presents experimental results and its assessment of a variable-speed wind power generation system (VSWPGS) using permanent magnet synchronous generator (PMSG) and boost chopper circuit (BCC). Experimental results are obtained by a test bench with a wind turbine emulator (WTE). WTE reproduces the behaviors of a windmill by using servo motor drives. The mechanical torque references to drive the servo motor are calculated from the windmill wing profile, wind velocity, and windmill rotational speed. VSWPGS using PMSG and BCC has three speed control modes for the level of wind velocity to control the rotational speed of the wind turbine. The control mode for low wind velocity regulates an armature current of generator with BCC. The control mode for middle wind velocity regulates a DC link voltage with a vector-controlled inverter. The control mode for high wind velocity regulates a pitch angle of the wind turbine with a pitch angle control system. The hybrid of three control modes extends the variable-speed range. BCC simplifies the maintenance of VSWPGS while improving reliability. In addition, VSWPGS using PMSG and BCC saves cost compared with VSWPGS using a PWM converter.

Development of Process Model for Turbine Control Valve Test in a Power Plant (발전소 터빈제어 밸브시험 계통 모델 개발)

  • Woo, Joo-Hee;Choi, In-Kyu;Park, Doo-Yong;Kim, Jong-An
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.4
    • /
    • pp.830-837
    • /
    • 2011
  • A turbine control system which has been operated for years in a nuclear power plant was retrofitted with a newly developed digital control system. After completion of the retrofit, turbine valve tests were performed to ensure the integrity of each valve's control function. The sequence of each valve test is composed of a closing process and a reopening process. To minimize megawatt variation which normally occurs during the test sequence, we employed a kind of compensator algorithm in the new digital control system which also have been used in the old system. There were difficulties finding optimal parameter settings for our new compensator algorithm because the power plant didn't allow us to perform necessary tuning procedures while the turbine is on load operation. Therefore an alternative measure for the compensator tuning which is independent of the turbine actual operation had to be implemented. So, a process model for the test was required to overcome this situation. We analyzed the operation data of the test and implemented the process model by use of input and output variable relations. Also we verified the process model by use of another condition's operating data. The result shows that the output of model is similar to the actual operation data.

Performance Improvement of Free Power Gas Turbine Type Gas Turbine Engine by Using of a MAT Cycle (MAT사이클을 이용한 분리축 가스터빈 엔진의 성능향상에 관한 연구)

  • 공창덕;김경두
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.5 no.2
    • /
    • pp.65-72
    • /
    • 2001
  • In order to improve the performance of a free power turbine type gas turbine engine by injecting the atomized water into a compressor inlet., a study on Moisture Air Turbine (MAT) cycle was proposed. Compressor work by air-water mixtures in phase change was theoretically considered, and it was found that the water evaporation might reduce the compressor work. Cycle model calculations predicted that power increments of 16.2%, 14.9% and 12.6% by 1.0% water to the air flow rate at the compressor intake with rotational shaft speeds of 1000, 1210, 1350 rps were obtained, and also thermal efficiency due to the reduction of compressor work was improved.

  • PDF

Performance Improvement of Free Power Gas Turbine Type Gas Turbine Engine by Using of a MAT Cycle (MAT사이클을 이용한 분리축 가스터빈 엔진의 성능향상에 관한 연구)

  • 공창덕;김경두;기자영;최인수
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2001.04a
    • /
    • pp.54-58
    • /
    • 2001
  • In order to Improve the performance of a free power turbine type gas turbine engine by injecting the atomized water into a compressor inlet., a study on Moisture Air Turbine (MAT) cycle was proposed. Compressor work by air-water mixtures in phase change was theoretically considered, and it was found that the water evaporation might reduce the compressor work. Cycle model calculations predicted that power increments of 21.7%, 20.2% and 18.4% by 1.5% water to the air flow rate at the compressor intake with rotational shaft speeds of 1000, 1210, 1350 rps were obtained, and also thermal efficiency due to the reduction of compressor work was improved.

  • PDF

Design Parameter Sensitivity Analysis of a 200kW Class Micro Gas Turbine System (200kW급 마이크로 가스터빈 시스템의 설계 변수 민감도 해석)

  • Shin, Hyun Dong;Kang, Do Won;Kim, Tong Seop;Choi, Mun-Kyoung;Park, Pil Je
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.6
    • /
    • pp.39-45
    • /
    • 2012
  • This paper describes the outcome of the design of a 200 kW class micro gas turbine and the sensitivity of its performance (efficiency and power) to the variations in major design parameters. The reference design parameters were set up based on the best available component technologies. The resulting net electricity generation efficiency of the micro gas turbine package was found to be competitive to those of other systems in the market. The sensitivities of power and efficiency to the variations in compressor and turbine efficiencies, pressure ratio, turbine inlet temperature, recuperator effectiveness, secondary air ratio, pressure loss ratios of both the cold and hot sides of the recuperator were estimated. Based on the sensitivity data, a simplified method to predict the variation in system performance responding to the combinations of small changes in all design parameters were set up and validated.

Air Similarity Test and Analysis of Steam Turbine Labyrinth Seal for Leakage Verification (스팀터빈용 래비린스 실의 누설량 규명을 위한 공기상사 실험 및 해석)

  • Ahn, Sang-Kyu;Kim, Seung-Jong;Lee, Yong-Bok;Kim, Chang-Ho;Ha, Tae-Wong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1149-1149
    • /
    • 2006
  • The leakage characteristic is an important factor in power plant. However, most of power plant have efficiency problem which is occurred leaking between high pressure steam turbine axle and stator. The labyrinth seal which is used between the main turbine axle and stator in the power plant. Because it is able to be non-contact seal and it is minimize clearance to decrease the leakage. But its actual system is too huge to experiment. Therefore, most steam turbine seal performance tests were conducted by air similarity test. This paper described a test facility and program for air similarity test of high pressure steam turbine seal. A test facility has been designed and built to evaluate leakage verification of labyrinth seal. The test facility consist of air compressor, anti-swirl labyrinth seal for 1/3 air similarity model, pressure transducer, air flow measure system, instrumentation and auxiliary system. For evaluation of steam turbine seal performance, the air similarity test of labyrinth seal leakage verification was conducted and we compared experiment data and analysis result.

  • PDF

A Study on the Optimum of Closed ${CO}_{2}$ Gas Turbine Process for Nuclear Energy Power Plant(I) (원자력 발전소에 대한 밀폐 ${CO}_{2}$ 가스터빈 프로세스의 최적화 연구 I)

  • 이찬규;이종원
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.3
    • /
    • pp.490-499
    • /
    • 1989
  • These days the closed cycle gas turbine attracts considerable attention due to : (1) The possibility of directly coupling the closed cycle gas turbine with a high temperature gas cooled reactor ; (2) the economical use of dry coolers to reduce the thermal charge of the environment ; and (3) the reduction of pollution and energy consumption, by replacing the domestic hearth by a central heating and power station. In this paper, we selected the optimal cycle from the characteristic of thermodynamic cycle for the optimal design of closed CO$_{2}$ gas turbine cycle usuable in nuclear energy power plant. Also the effects of between the parameters and thermal efficiency were investigated by computer simulation. These results and design data will be added to basics in optimal designing closed CO$_{2}$ cycle gas turbine plant.

Study on Performance Improvement of an Axial Flow Hydraulic Turbine with a Collection Device

  • Nishi, Yasuyuki;Inagaki, Terumi;Li, Yanrong;Hirama, Sou;Kikuchi, Norio
    • International Journal of Fluid Machinery and Systems
    • /
    • v.9 no.1
    • /
    • pp.47-55
    • /
    • 2016
  • The portable hydraulic turbine we previously developed for open channels comprises an axial flow runner with an appended collection device and a diffuser section. The output power of this hydraulic turbine was improved by catching and accelerating an open-channel water flow using the kinetic energy of the water. This study aimed to further improve the performance of the hydraulic turbine. Using numerical analysis, we examined the performances and flow fields of a single runner and a composite body consisting of the runner and collection device by varying the airfoil and number of blades. Consequently, the maximum values of input power coefficient of the Runner D composite body with two blades (which adopts the MEL031 airfoil and alters the blade angle) are equivalent to those of the composite body with two blades (MEL021 airfoil). We found that the Runner D composite body has the highest turbine efficiency and thus the largest power coefficient. Furthermore, the performance of the Runner D composite body calculated from the numerical analysis was verified experimentally in an open-channel water flow test.

Design and control performance validation of HILS system based on MATLAB/Simulink (MATLAB/Simulink기반 HILS 환경 구축 및 제어 성능 검증)

  • Min-Woo Ham;Insu Paek
    • Journal of Wind Energy
    • /
    • v.15 no.1
    • /
    • pp.60-68
    • /
    • 2024
  • In this study, a hardware-in-the-loop simulation (HILS) environment was established using MATLAB/Simulink to simulate and verify the power performance of a wind turbine. The target wind turbine was selected as the NREL 5 MW model, and modeling was performed based on the disclosed specifications. The HILS environment consists of a PC equipped with a MATLAB/Simulink program, a programmable logic controller (PLC) for uploading and linking control algorithms, and data acquisition (DAQ) equipment to manage wind turbine data input and output. The operation of the HILS environment was carried out as a procedure of operation (PC) of the target wind turbine modeled based on MATLAB/Simulink, data acquisition (PLC) of control algorithms, control command calculation (PLC), and control command input (PC). The simulation was performed using the HILS environment under turbulent wind conditions and compared with the simulation results performed under the same conditions in the HILS environment using the commercial program Bladed for performance verification. From the comparison, it was found that the dynamic simulation results of the Bladed HILS and the MATLAB HILS were close in power performances and the errors in the average values of rotor rotation speed and power generation between the two simulations were about 0.44 % and 3.3 %, respectively.

A Study on the Reliability Improvement of the Turbine Control Valve System in Nuclear and Thermal Power Plants (원자력/화력발전소의 터빈제어밸브시스템의 신뢰성 향상에 관한 연구)

  • Yang, Jong Dae;Yang, Seok Jo;Lee, Yong Bum
    • Journal of Drive and Control
    • /
    • v.16 no.4
    • /
    • pp.93-100
    • /
    • 2019
  • Nuclear and thermal power plants must provide the turbines with an appropriate degree of high temperature and high pressure steam, to produce the optimum electricity. Additionally, in the event of system and power system failure during electrical production, the steam is immediately disabled, to protect the turbines and generators rotating at high speed. The plant thus uses a special steam control valve system for turbine control, which is opened by force of the hydraulic servo actuator and closed by a large steel spring force. In this study, the causes of failure of the turbine control valve system, a key device of the power plants, were analyzed, and the causes of failure were improved relative to reliability of the equipment.