• 제목/요약/키워드: Power Transmission Systems

검색결과 1,409건 처리시간 0.032초

Pump Light Porer of Wideband Optical Phase Conjugator Dependence on Amplifier Spacing in 320 Gbps WDM Systems with MSSI

  • Lee Seong-Real
    • 한국통신학회논문지
    • /
    • 제31권8A호
    • /
    • pp.735-744
    • /
    • 2006
  • In this paper, the optimum pump light powers of optical phase conjugator(OPC) are numerically investigated as a function of amplifier spacing in 1,200 km $8{\times}40$ Gbps WDM systems with 0.1, 0.4, 0.8, or 1.6 ps/nm/km dispersion coefficient. It is confirmed that the variation of optimal pump light power dependence on amplifier spacing for NRZ transmission system is smaller than that for RZ transmission system through the evaluations and analysis of eye opening penalty(EOP) characteristics. And, in both cases of NRZ and RZ transmission, the variation of optimal pump light power is more increased as amplifier spacing becomes longer. Additionally, it is confirmed that the best amplifier spacing in NRZ and RZ transmission system is 50 km.

Fitness Sharing Particle Swarm Optimization Approach to FACTS Installation for Transmission System Loadability Enhancement

  • Chang, Ya-Chin
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.31-39
    • /
    • 2013
  • Proper installation of Flexible AC Transmission Systems (FACTS) devices in existing transmission networks can enable power systems to accommodate more power transfer with less network expansion cost. The problem to maximize transmission system loadability by determining optimal locations and settings for installations of two types of FACTS devices, namely static var compensator (SVC) and thyristor controlled series compensator (TCSC), is formulated as a mixed discrete-continuous nonlinear optimization problem (MDCP). For solving the MDCP, in the paper, the proposed method with fitness sharing technique involved in the updating process of the particle swarm optimization (PSO) algorithm, can diversify the particles over the search regions as much as possible, making it possible to achieve the optimal solution with a big probability. The modified IEEE-14 bus network and a practical power system are used to validate the proposed method.

동력경운기(動力耕耘機) 기관(機関)의 효율적(效率的) 이용(利用)에 관한 연구(硏究) (A Study on Efficient Utilization of Power-Tiller Engines)

  • 류관희;박금주
    • Journal of Biosystems Engineering
    • /
    • 제9권2호
    • /
    • pp.1-7
    • /
    • 1984
  • The engines mounted on power-tillers are used as power source in various kinds of works such as plowing, harrowing, transporting, spraying, water pumping and threshing, etc. But the engines have not been used effectively from a standpoint of fuel consumption because of lack of proper power transmission system and lack of understanding of fuel consumption characteristics of the engines. Therefore, this study was attempted to establish proper power transmission system between the power-tiller engines and various implements. In order to accomplish the above objective, firstly, power requirement and pulley sizes for various implements, which are driven by the power-tiller engines, were investigated to find out whether the power transmission system is proper. Secondly, partload variable engine-speed test was conducted for 3 different sizes of diesel engines to measure to specific fuel consumption. Thirdly, the present power transmission systems were analyzed in terms of specific fuel consumption, and proper power transmission systems were suggested for various implements. The results of this study are summarized as follows: 1. Power requirement for each fixed-type implement of power-tiller varied from 1.5 ps to 11 ps according to its type and operating conditions, but generally in the range of 2.5 ps to 7 ps. 2. Each power tiller and implement were equipped with only one size of pully with few exeptions. With the present power transmission systems, the engines can't be utilized effectively in terms of fuel economy. The pulley size of engine or implement should be diversified to provide the optimum engine speed for different implements. 3. For a diesel eninge with the rated power output of 6 ps, the optimum engine speed to minimize specific fuel consumption was 2200 rpm for the power reguirement in the range of 6 ps or more, 1700 rpm in the range of 4 to 6 ps, and 1200 rpm in the range of 4 ps or less. 4. For a diesel engine with the rated power output of 8 ps, the optimum engine speed was 2200 rpm for the power requirement in the range of 7 ps or more, 1700 rpm in the range of 4.8 to 7 ps, and 1200 rpm in the range of 4.8 ps or less. 5. For a diesel engine with the rated power output of 10 ps, the optimum engine speed was 2200 rpm for the power requirement in the range of 8.4 ps or more, 1700 rpm in the range of 5.4 ps to 8.4 ps, and 1200 rpm in thr range of 5.4 ps or less. 6. Provided the existing implements are dirven by 8 ps diesel engines, the optimum size of engine pulley should be larger than 120mm for the works of requiring less than 4 ps and 90-110mm for the works requiring 4.5-6.5 ps in order to minimize fuel consumption.

  • PDF

A Mathematical Approach to Allocate the Contributions by Applying UPFCs to Transmission System Usage

  • Sedaghati, Alireza
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.158-163
    • /
    • 2005
  • Competitive electricity markets necessitate equitable methods for allocating transmission usage in order to set transmission usage charges and congestion charges in an unbiased and an open-accessed basis. So in competitive markets it is usually necessary to trace the contribution of each participant to line usage, congestion charges and transmission losses, and then to calculate charges based on these contributions. A UPFC offers flexible power system control, and has the powerful advantage of providing, simultaneously and independently, real-time control of voltage, impedance and phase angle, which are the basic power system parameters on which sys-tem performance depends. Therefore, UPFC can be used efficiently and flexibly to optimize line utilization and increase system capability and to enhance transmission stability and dampen system oscillations. In this paper, a mathematical approach to allocate the contributions of system users and UPFCs to transmission system usage is presented. The paper uses a dc-based load flow modeling of UPFC-inserted transmission lines in which the injection model of the UPFC is used. The relationships presented in the paper showed modified distribution factors that modeled impact of utilizing UPFCs on line flows and system usage. The derived relationships show how bus voltage angles are attributed to each of changes in generation, injections of UPFC, and changes in admittance matrix caused by inserting UPFCs in lines. The relationships derived are applied to two test systems. The results illustrate how transmission usage would be affected when UPFC is utilized. The relationships derived can be adopted for the purpose of allocating usage and payments to users of transmission network and owners of UPFCs used in the network. The relationships can be modified or extended for other control devices.

  • PDF

혼합송전계통에서 웨이브렛 변환을 이용한 고장점 탐색 알고리즘에 관한 연구 (A Study on a Fault Location Algorithm Using Wavelet Transform in Combined Transmission Systems)

  • 정채균;이종범;윤양웅
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권5호
    • /
    • pp.247-254
    • /
    • 2002
  • This paper describes a fault location algorithm in real combined transmission systems with underground power cable. The algorithm to calculate the fault location was developed using DWT wavelet transform and travelling wave occurred at fault point. And the proposed algorithm is also used the transient signal of one end in stead of the signal information of two ends. On the other hand, in this papers, the method to discriminate fault point between overhead line and cable section is also Proposed. Variety simulations were carried out to verify the accuracy and effectiveness of the proposed algorithm using EMTP/ATFDraw and Matlab. Simulation results show that the proposed method has the excellent ability for discrimination of fault section and fault location in combined transmission systems with power cables.

A Digital Data Transmission Unit using Asynchronous Protocol for Power Transmission line

  • Nishiyama, Eiji;Kuwanami, Kenshi;Kitajima, Hiroyuki;Kawano, Mitsunori
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.79.6-79
    • /
    • 2002
  • We propose here sequential 2 methods for obtain information of current or potential data for power transmission line. One is a digital data transmission unit, this is, an output of a current sensor of power transmission line is digitalized by use of an easy asynchronous protocol. The unit has high speed transform rate, easy making header caused of consisting of only logic circuit. The other is, the output of the unit is transformed via LAN interface and displayed on a personal computer. We have confirmed remote measuring using the method for 100A and 240 A of the current information of power transmission line. Therefore we will be able to see a current waveform by use of internet at a cheep c...

  • PDF

Integrated Optimization of Combined Generation and Transmission Expansion Planning Considering Bus Voltage Limits

  • Kim, Hyoungtae;Kim, Wook
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1202-1209
    • /
    • 2014
  • A novel integrated optimization method is proposed to combine both generation and transmission line expansion problem considering bus voltage limit. Most of the existing researches on the combined generation and transmission expansion planning cannot consider bus voltages and reactive power flow limits because they are mostly based on the DC power flow model. In this paper the AC power flow model and nonlinear constraints related to reactive power are simplified and modified to improve the computation time and convergence. The proposed method has been successfully applied to Garver's six-bus system which is one of the most frequently used small scale sample systems to verify the transmission expansion method.

Investigation of the effects of common and separate ground systems in wireless power transfer

  • Park, Woocheon;Moon, Jung-Ick;Cho, In-kui
    • ETRI Journal
    • /
    • 제44권2호
    • /
    • pp.339-345
    • /
    • 2022
  • This article presents an investigation of the effects on a grounding system of wireless power transfer (WPT) when transmitting over relatively far distances, that is, up to 1.25 m. Conventional two-coil WPT systems are sufficiently commercialized in strong coupling range, but it is important to accomplish the long-range WPT in weak coupling range for further various applications. This system depends on the coupling effect between the two coils that the grounds of the transmitting and receiving coils should be completely separated. However, when evaluating the performance of two-coil systems with the instrument consisting of two ports and one common ground, undesirable problems occur in weak coupling ranges, for example, obtaining disagreeable transmission efficiency and degrading system stability/reliability. We investigate the problems of the leakage power from common ground systems and provide a practical solution to obtain a reliable WPT system by using an isolation transformer. The usefulness of this approach is that it is possible to achieve the stability of the system with relatively far transmitting distances and to determine the exact transmission efficiency.

TRELSS를 이용한 전력계통의 확률론적 신뢰도 평가 VI - 송전망 확충계획시 응용에 관한 사례연구 - (Probabilistic Reliability Evaluation of Power System using TRELSS VI - Case Study on Transmission Line Planning -)

  • 김형철;트란트룽틴;최재석;전동훈;추진부;허연;한경남
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.78-82
    • /
    • 2004
  • This paper suggests the power system reliability evaluation fur transmission lines planning in composite power systems. In recent the importance and necessity of some studies on reliability evaluation of grid comes from the recent black-out accidents occurred in the world. Since probabilistic criterion can reflect recognize the probabilistic nature of system components, the application of probabilistic criterion has received a lot of attention. This paper introduces features and operation modes of the Transmission Reliability Evaluation fur Large-Scale Systems(TRELSS) Version 6.2, a program made in EPRI, for assessing reliability indices of composite power system. The characteristics of the TRELSS program are illustrated by the case studies using the KEPCO system.

  • PDF

EMTP/ATPDraw를 이용한 가스절연송전선로(GIL)의 과전압 분석 (An Analysis on the Overvoltage in Gas Insulated Transmission Lines with EMTP/ATPDraw)

  • 박흥석;한상옥
    • 전기학회논문지
    • /
    • 제60권5호
    • /
    • pp.999-1004
    • /
    • 2011
  • Nowadays, it is becoming difficult to secure a transmission line route when a new transmission line is constructed due to social environment and resident complaints. As existing urban areas are expanded and new cities are constructed, the necessity of high-capacity underground power transmission has been increasing because of load concentration in downtown areas. In North America, Europe and Japan, the research has been carried out for 2nd generation gas insulated transmission lines(GIL) which is more environmentally friendly and economical compared to previous GILs. The new GILs have been applied to real power systems from early 2000s. In South Korea, GIL is being considered as a possible solution for replacing 345kV high-capacity overhead transmission lines with underground transmission ones, so KEPCO is planning to develop and apply a new 362kV rated GIL underground transmission lines instead of overhead transmission lines. In this paper, the overvoltage generated at the combined transmission line adapting GIL was reviewed using EMTP.