• 제목/요약/키워드: Power Transmission Systems

검색결과 1,404건 처리시간 0.034초

Development of a Measuring Instrument of Current and Voltage on Power-Transmission Lines for the Construction of Energy-Network

  • Park, Kyi-Hwan;Jiang, Zhongwei
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.107.2-107
    • /
    • 2001
  • We propose portable equipment that monitors a current and potential on high-potential power transmission lines. In the equipment, a current and voltage sensor are attached to a hollow insulator that supports a power transmission line: A current on a power line is detected by an air-core solenoidal coil clamped to the line and the detected current signal is transmitted to the ground station by using optical data link, A potential on a power transmission line is detected by a high resistance element, zinc oxide (ZnO) that acts as a potential divider between the power line and the ground. The equipment does not require high potential insulators and magnetic cores which. This leads to the following advantages of the equipment: (a) It is easily installed owing to its small size and its simple structure; (b) It operates in low ...

  • PDF

파워흐름해석을 위한 비보존 조인트로 편성된 평판 구조물의 파워투과반사계수 해석 (Wave Transmission Approach of Coupled Plate Structures through Non-conservative Joints for Power Flow Analysis)

  • 송지훈;홍석윤;박영호;박도현;길현권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.505-510
    • /
    • 2002
  • The attenuation of waves transmitted through non-conservative joints that are shown in many paractical structures, is affected by the impedance and the orientation of the joint. In this paper, the joints between plate structures are assumed to be modeled as linear spring-dashpot systems and the transmission and reflection of vibration energy in the medium to high frequency ranges are investigated. The calculated power transmission and reflection coefficients are applied to the PFA method for the prediction of energy density and intensity in structures.

  • PDF

전압플리커 저감과 역률 보상 기능을 갖는 배전용 STATCOM의 실계통연계 운전결과 분석 (Analysis of the Distribution STATCOM for Improving the power factor and Mitigation of Voltage Flicker in Real System)

  • 오관일;전영수;박상태;추진부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.245-248
    • /
    • 2000
  • This paper presents the test and operation results of the domestic demonstration of the reactive power compensation device called STATCOM (STATic COMpensator). The object of the paper is to describe the reliability of the unit based on the extensive operation databases. By controlling reactive power, the technology offers utilities the opportunity for increased efficiency and their capabilities will permit transmission planners make the best use of their existing transmission resources STATCOM is a custom power device in a way and can be used in a similar way for the dynamic compensation of power transmission systems, mitigation of voltage flicker and improving the power factor. It is shown that the STATCOM has clear advantages in areas such as: mitigation of voltage flicker and improving power factor.

  • PDF

Economic Evaluation of Transmission Expansion for Investment Incentives in a Competitive Electricity Market

  • Fischer, Robert;Joo, Sung-Kwan
    • International Journal of Control, Automation, and Systems
    • /
    • 제6권5호
    • /
    • pp.627-638
    • /
    • 2008
  • With the shift of the electric power industry from a regulated monopoly structure to a competitive market environment, the focus of the transmission expansion planning has been moving from reliability-driven transmission expansion to market-based transmission expansion. In market-based transmission expansion, however, a growing demand for electricity, an increasing number of transmission bottlenecks, and the falling levels of transmission investment have created the need for an incentive to motivate investors. The expectation of profit serves as a motivational factor for market participants to invest in transmission expansion in a competitive market. To promote investment in transmission expansion, there is an increasing need for a systematic method to examine transmission expansion for investment incentives from multiple perspectives. In this paper, the transmission expansion problem in a competitive market environment is formulated from ISO and investors' perspectives. The proposed method uses parametric analysis to analyze benefits for investors to identify the most profitable location and amount for transmission addition. Numerical results are presented to demonstrate the effectiveness of the proposed method.

Performance Evaluation of a Driving Power Transmission System for 50 kW Narrow Tractors

  • Hong, Soon-Jung;Ha, Jong-Kyou;Kim, Yong-Joo;Kabir, Md. Shaha Nur;Seo, Young Woo;Chung, Sun-Ok
    • Journal of Biosystems Engineering
    • /
    • 제43권1호
    • /
    • pp.1-13
    • /
    • 2018
  • Purpose: The development of compact tractors that can be used in dry fields, greenhouses, and orchards for pest control, weeding, transportation, and harvesting is necessary. The development and performance evaluation of power transmission units are very important when it comes to tractor development. This study evaluates the performance of a driving power transmission unit of a 50 kW multi-purpose narrow tractor. Methods: The performance of the transmission and forward-reverse clutch, which are the main components of the driving power transmission unit of multi-purpose narrow tractors, was evaluated herein. The transmission performance was evaluated in terms of power transmission efficiency, noise, and axle load, while the forward-reverse clutch performance was evaluated in terms of durability. The transmission's power transmission efficiency accounts for the measurement of transmission losses, which occur in the transmission's gear, bearing, and oil seal. The motor's power was input in the transmission's input shaft. The rotational speed and torque were measured in the final output shaft. The noise was measured at each speed level after installing a microphone on the left, right, and upper sides. The axle load test was performed through a continuous equilibrium load test, in which a constant load was continuously applied. The forward-reverse clutch performance was calculated using the engine torque to axle torque ratio with the assembled engine and transmission. Results: The loss of power in the transmission efficiency test of the driving power unit was 6.0-9.7 kW based on all gear steps. This loss of horsepower was equal to 11-18% of the input power (52 kW). The transmission efficiency of the driving power unit was 81.5-89.0%. The noise of the driving power unit was 50-57 dB at 800 rpm, 70-77 dB at 1600 rpm, and 76-83 dB at 2400 rpm. The axle load test verified that the input torque and axle revolutions were constant. The results of the forward-reverse clutch performance test revealed that hydraulic pressure and torque changes were stably maintained when moving forward or backward, and its operation met the hydraulic design standards. Conclusions: When comprehensively examined, these research results were similar to the main driving power transmission systems from USA and Japan in terms of performance. Based on these results, tractor prototypes are expected to be created and supplied to farmhouses after going through sufficient in-situ adaptability tests.

송전계통 고저항 지락사고 보호기술 현황 및 개발전망 (Present State and Development Prospect on the Protective Relaying Under High Resistance Earth Faults in Transmission Systems)

  • 이종범;김일동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 B
    • /
    • pp.640-642
    • /
    • 1995
  • This paper describes the present state and development prospect on the protective relaying under high resistance earth faults in transmission systems. Especially it is difficult to detect the fault accompanied with high resistance contary to low resistance. In the complicated power system if the detection is failed, power failure will be occured in large area. New technology with respect to such a problem must be developed. This paper introduces research and development trend in home and abroad.

  • PDF

Research on Discontinuous Pulse Width Modulation Algorithm for Single-phase Voltage Source Rectifier

  • Yang, Xi-Jun;Qu, Hao;Tang, Hou-Jun;Yao, Chen;Zhang, Ning-Yun;Blaabjerg, Frede
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권4호
    • /
    • pp.433-445
    • /
    • 2014
  • Single phase voltage source converter (VSC) is an important power electronic converter (PEC), including single-phase voltage source inverter (VSI), single-phase voltage source rectifier (VSR), single-phase active power filter (APF) and single-phase grid-connection inverter (GCI). As the fundamental part of large scale PECs, single-phase VSC has a wide range of applications. In the paper, as first, on the basis of the concept of the discontinuous pulse-width modulation (DPWM) for three-phase VSC, a new DPWM of single-phase VSR is presented by means of zero-sequence component injection. Then, the transformation from stationary frame (abc) to rotating frame (dq) is designed after reconstructing the other orthogonal current by means of one order all-pass filter. Finally, the presented DPWM based single-phase VSR is established analyzed and simulated by means of MATLAB/SIMULINK. In addition, the DPWMs presented by D. Grahame Holmes and Thomas Lipo are discussed and simulated in brief. Obviously, the presented DPWM can also be used for single-phase VSI, GCI and APF. The simulation results show the validation of the above modulation algorithm, and the DPWM based single-phase VSR has reduced power loss and increased efficiency.

동적 구속조건을 적용한 자동변속장치의 효과적인 시뮬레이션방법에 관한 연구 (A study on the efficient simulation methods for an automatic power transmission system applying dynamic torque constraint)

  • 정헌술;이교일
    • 대한기계학회논문집A
    • /
    • 제22권3호
    • /
    • pp.504-518
    • /
    • 1998
  • Degree-Of-Freedom(DOF) for most power transmission system varies according to the operation status which consists of friction elements to change the power flow or to adjust the speed ratio such as clutches, brakes or one-way clutches. To simulate the dynamic characteristics of automatic power transmission system which is a typical example of such a variable DOF systems, many sets of governing equations and complicated phase decision routines are necessary. In this paper dynamic constraint theorem is derived explaining the torque transmission characteristics during the clutch engagement process and a robust stable algorithm is developed describing this phase transition phenomenon effectively by introducing the concept of direct torque and virtual damping. Finally, applying this algorithm to a passenger car automatic transmission gear consisting of several friction elements, an efficient simulation methods for such a complex system will be suggested that is very simple and systematic.

A Method for Fault detecting on Power Transmission Network by use of M-sequence Correlation

  • Nishiyama, Eiji;Kuwanami, Kenshi;Owaki, Kosuke
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.2570-2575
    • /
    • 2003
  • Monitoring a power transmission line is significant for power electric companies. In this paper, we propose a new method for detecting an fault point of power transmission line by use of M-sequence correlation technique. In this method, detecting signal is used as one or plural M-sequences ( same characteristic polynomial, including normal and reverse mark, synchronized ). In receiving point, we make same sequence with the input one and take crosscorrelation function between M-sequence and the received signal. We can see transfer fanctions of plural paths between inputs and a output taps separated from different of delay times on the crosscorrelation function, and from these transfer fanctions, so we compare them when fault occurred with in usual.

  • PDF

전력계통의 안정도 진단이 가능한 선로 선정에 관한 연구 (Identification of Correlative Transmission Lines for Stability Diagnosis of Power System)

  • 조윤성;장길수;권세혁
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권5호
    • /
    • pp.271-278
    • /
    • 2003
  • Power system stability is correlated with system structure, disturbances and operating conditions, and power flows on transmission lines are closely related with those conditions. This paper proposes a methodology to identify correlative power flows for power system transient and small-signal stability prediction. In transient stability sense, the Critical Clearing Time is used to select some dominant contingencies, and Transient Stability Prediction index is proposed for the quantitative comparison. For small-signal stability, this paper discusses a methodology to identify crucial transmission lines for stability Prediction by introducing a sensitivity factor based on eigenvalue sensitivity technique. On-line monitoring of the selected lines enables to predict system stability in real-time. Also, a Procedure to make a priority list of monitored transmission lines is proposed. The procedure is applied to a test system and the KEPCO systems in the year of 2003 and it shows capabilities of the proposed method