스팀터빈 발전기 비동기 투입 사례연구를 통한 비동기 방지 알고리즘 개발 (Development of Asynchronous Blocking Algorithm through Asynchronous Case Study of Steam Turbine Generator)

  • 이종훤
    • 전기학회논문지
    • /
    • 제61권10호
    • /
    • pp.1542-1547
    • /
    • 2012
  • Asynchronous phenomenon occurs on the synchronous generators under power system when a generator's amplitude of electromagnetic force, phase angle, frequency and waveform etc become different from those of other synchronous generators which can follow instantly varying speed of turbine. Because the amplitude of electromagnetic force, phase frequency and waveform differ from those of other generators with which are to be put into parallel operation due to the change of excitation condition for load sharing and the sharing load change, if reactive current in the internal circuit circulates among generators, the efficiency varies and the stator winding of generators are overheated by resistance loss. When calculation method of protection settings and logic for protection of generator asynchronization will be recommended, a distance relay scheme is commonly used for backup protection. This scheme, called a step distance protection, is comprised of 3 steps for graded zones having different operating time. As for the conventional step distance protection scheme, zone 2 can exceed the ordinary coverage excessively in case of a transformer protection relay especially. In this case, there can be overlapped protection area from a backup protection relay and, therefore, malfunctions can occur when any fault occurs in the overlapped protection area. Distance relays and overcurrent relays are used for backup protection generally, and both relays have normally this problem, the maloperation, caused by a fault in the overlapped protection area. Corresponding to an IEEE standard, this problem can be solved with the modification of the operating time. On the other hand, in Korea, zones are modified to cope with this problem in some specific conditions. These two methods may not be obvious to handle this problem correctly because these methods, modifying the common rules, can cause another coordination problem. To overcome asynchronizing protection, this paper describes an improved backup protection coordination scheme using a new logic that will be suggested.

임피던스 계전기를 이용한 발전기 비동기 투입 보호 연구 (A Study on Protection of Generator Asynchronization by Impedance Relaying)

  • 이종훤
    • 전기학회논문지
    • /
    • 제60권11호
    • /
    • pp.2000-2006
    • /
    • 2011
  • Asynchronous phenomenon occurs on the synchronous generators under power system when a generator's amplitude of electromagnetic force, phase angle, frequency and waveform etc become different from those of other synchronous generators which can follow instantly varying speed of turbine. Because the amplitude of electromagnetic force, phase frequency and waveform differ from those of other generators with which are to be put into parallel operation due to the change of excitation condition for load sharing and the sharing load change, if reactive current in the internal circuit circulates among generators, the efficiency varies and the stator winding of generators are overheated by resistance loss. Where calculation method of protection settings and Logic for Protection of Generator Asynchronization will be recommended, A distance relay scheme is commonly used for backup protection. This scheme, called a step distance protection, is comprised of 3 steps for graded zones having different operating time. As for the conventional step distance protection scheme, Zone 2 can exceed the ordinary coverage excessively in case of a transformer protection relay especially. In this case, there can be overlapped protection area from a backup protection relay and, therefore, malfunctions can occur when any fault occurs in the overlapped protection area. Distance relays and overcurrent relays are used for backup protection generally, and both relays have normally this problem, the maloperation, caused by a fault in the overlapped protection area. Corresponding to an IEEE standard, this problem can be solved with the modification of the operating time. On the other hand, in Korea, zones are modified to cope with this problem in some specific conditions. These two methods may not be obvious to handle this problem correctly because these methods, modifying the common rules, can cause another coordination problem. To overcome asynchronizing protection this paper describes an improved backup protection coordination scheme using a new Logic that will be suggested.

PSCAD/EMTDC를 이용한 풍력발전의 배전계통 사고특성에 관한 연구 (A Study on Fault Characteristics of DFIG in Distribution Systems Based on the PSCAD/EMTDC)

  • 손준호;김병기;전진택;노대석
    • 한국융합학회논문지
    • /
    • 제2권2호
    • /
    • pp.47-56
    • /
    • 2011
  • 2008년도 지식경제부의 전망에 의하면 신재생에너지전원 중 풍력발전의 보급전망은 2020년 37%, 2030년 42%에 달하고, 2012년부터 시행 예정인 신재생에너지 의무할당제(Renewable Portfolio Standard-RPS)의 도입으로 태양광 및 풍력 등의 신재생에너지가 향후 지속적으로 배전계통에 연계 운용될 것으로 예상된다. 현재 풍력은 배전계통에 전용선로로 연계되어 계통에 미치는 영향은 미미하지만, 3[MW] 이상의 대규모 풍력발전이 일반 배전선로로 확대 운용되면, 풍력발전 연계용 변압기 및 풍력발전기의 %임피던스에 의한 사고전류 변동으로 보호계전기(OCR, OCGR)의 오 부동작을 야기할 수 있다. 따라서 본 논문에서는 대표적인 풍력발전기인 이중여자유도발전기(Double-Fed Induction Generator-DFIG)가 고압 배전선로에 연계되어 운전되는 경우, 3상단락, 2선단락 및 1선지락의 사고특성을 분석하기 위하여, 전력계통 상용소프트웨어인 PSCAD/EMTDC를 이용하여 풍력발전기의 모델링과 시뮬레이션을 수행하고, 대칭좌표법을 통한 이론적인 수치해석의 결과치를 비교/분석하여, 제안한 수법의 유용성을 확인하였다.

2차회로의 직.병렬연결에 따른 하이브리드형 초전도 한류기의 특성 (Characteristics of a Hybrid-type SFCL with Serial and Parallel Connection of Secondary Circuit)

  • 조용선;박형민;남긍현;이나영;한태희;최효상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.393-395
    • /
    • 2006
  • We investigated the operational characteristics of the hybrid-type superconducting fault current limiter (SFCL) according to the serial and parallel connections of secondary circuits. The hybrid-type SFCL consists of a transformer, which has a primary winding and several secondary windings with $YBa_2Cu_3O_7$ films connected in series and parallel. In order to increase the capacity of the SFCL, the serial connection between each current limiting unit is necessary. The hybrid-type SFCL with the serial connection in secondary circuits could show superior characteristics than those of the parallel connections in the current limiting and quench time. The resistances generated in the superconducting units were also lowered at the parallel connections. We confirmed that the parallel connection reduced the power burden of each superconducting unit under the same conditions because of the simultaneous quenching between superconducting units.

  • PDF

직렬 전압주입에 의한 순간전압강하 보상기기에 관한 연구 (A Study on the Instantaneous Voltage Drop Compensator through the Series Voltage Injection)

  • 전영환;김지원;전진홍
    • 에너지공학
    • /
    • 제10권4호
    • /
    • pp.310-317
    • /
    • 2001
  • 동일한 변압기에서 인출된 서로 다른 선로중 하나의 선로에서 고장이 발생하는 경우 다른 선로에서는 순간적인 전압강하 현상을 경험하게 된다. 이렇게 발생되는 순간전압강하 현상은 비록 선로의 계전기에 의해 사고가 제거되기까지의 짧은 기간동안 지속되지만 기기에 따라서는 막대한 피해를 유발할 수 있다. 예로서, 반도체 공장의 정밀 공정중 순간전압강하가 발생하면 공정이 중단되거나 공정의 재시작등으로 인하여 a가대한 경제적 손실을 유발하게 된다. 또한 각종 정밀기기 등에는 기기의 수명저하를 유발하기도 한다. 본 논문에서는 전력계통에 직렬로 연결되는 인버터 시스템을 이용하여 계통에 전압을 주입함으로서 순간전압강하를 보상할 수 있는 시스템에 관하여 연구하고 운전 알고리즘을 제시하였다. 컴퓨터 시뮬레이션과 실험을 통하여 제시한 운전알고리즘의 유효성을 입증하였다.

  • PDF

2차회로의 수에 따른 하이브리드형 초전도 한류기의 동작 특성 (Characteristics of Hybrid-Type SFCL by the Number of Secondary Windings with YBCO Films)

  • 조용선;최효상;박형민
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권2호
    • /
    • pp.62-66
    • /
    • 2006
  • We investigated the characteristics of the hybrid-type superconducting fault current limiter (SFCL) by the number of secondary windings. The SFCL consists of a transformer, which has a primary winding and several secondary windings with serially connected $YB_{a2}Cu_{3}O_{7}$ films. In order to increase the capacity. of the SFCL, the serial connection between each current limiting unit is necessary. Resistive-type SFCL has a difficulty in quenching simultaneously between the units due to slight differences of their critical current densities. The hybrid-type SFCL could achieve the simultaneous quenching through the electrical isolation and the mutual flux linkage among the units. We confirmed that the capacity of the SFCL could be increased effectively through the simultaneous quenching among the units. In addition, the power burden of the system could be reduced by adjusting the number of secondary windings. We will investigate the method to increase the capacity through serial and Parallel connections among current limiting units.

Quench characteristics of YBCO thin films using magnetic field source for superconducting fault current limiters

  • Lee, B.W.;Park, K.B.;Kang, J.S.;Oh, I.S.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권2호
    • /
    • pp.11-14
    • /
    • 2004
  • YBCO thin films have good characteristics for current limiting materials due to compact size and high current carrying capability. But the irregularities and the extreme thin thickness of YBCO films cause some difficulties in simultaneous quench and thermal shock protection. In order to solve these problems, vertical magnetic field generated from solenoid coil was applied to the YBCO element. And also to minimize the inductance caused by the serial connection of magnetic field source with superconducting elements, magnetic field source was separated from the power lines adapting protective current transformer. In this study, electric field-current (E-I) and quench characteristics of YBCO films were analyzed both by electrical measuring method and observations of bubble propagation. From the experiment results, it was revealed that the magnetic fields generated by surrounding coil could induce the uniform quench distribution for all stripes of current limiting units and finally simultaneous quenches were realized in all serial connection of YBCO elements. In addition, the separation of magnetic field source form electrical network could be good solution for simultaneous quench of YBCO films without any unnecessary effect caused by serial connection.

유침 절연에서 전기적 및 열적 열화에 따른 유중가스분포특성 (Characterisrics of Dissolved Gas Distribution in Oil with Thermal and Electrical Degradation in Oil Imersed Paper Insulation)

  • 선종호;이상화;김광화
    • 조명전기설비학회논문지
    • /
    • 제18권6호
    • /
    • pp.136-144
    • /
    • 2004
  • 본 논문에서는 유침절연에 대한 열열화와 전기적열화 실험을 실시하여 유중가스분석법을 이용한 유침절연의 고장원인 진단에 대한 신뢰성을 향상시키는 방안에 대하여 연구하였다. 유침절연의 고장원인에 대하여 주도가스법과 탄화수소가스의 구성률, CO/$CO_2$비와 같은 진단요소를 단독으로 사용하는 것보다는 진단요소들의 상호관계를 이용하는 것이 유침절연의 고장원인을 신뢰성 있게 진단하는 것으로 나타났다.

자가용 전기설비 안전관리자의 PL인식 조사 및 사고사례 연구 (The Study on Facility Accident Case and PL Recognition of the Safety Manager in Electric Installation for Private Use)

  • 김영석;송길목;김선구
    • 조명전기설비학회논문지
    • /
    • 제22권9호
    • /
    • pp.40-46
    • /
    • 2008
  • 본 논문에서는 자가용 전기설비에서 전기안전관리자의 PL인식과 전기설비의 사고발생에 관한 것을 조사하였다. 설문대상은 자가용 수용가 450호를 선정하였으며, 이중 154호가 설문에 응신하여 35.8[%]를 차지하였다 전기안전관리자의 58[%]는 PL에 관해 잘 알고 있었으며, 42[%]는 인식하고 있지 않았다. 이들 중 82.4[%]는 전기설비에 PL법이 적용되어야 된다고 하였으며, 5.8[%]만이 PL법의 적용이 필요 없다고 대답하였다. PL적용의 이유로는 전기설비와 제품의 안정성을 위한 것이 64[%], 동일사고의 방지가 19[%]를 차지하였다. 또한 변압기 사고가 가장 많은 부분을 차지하였으며, 케이블 사고가 그 뒤를 따랐다. 설문조사 결과로부터, 전기안전관리자들은 PL내용에 많은 관심이 있었으며, 그들은 전기사고에 관한 PL적용의 필요성을 기대하고 있었다.

태양광전원이 연계된 고압배전선로의 보호협조 평가 방안에 관한 연구 (Evaluation Method for Protection Coordination of PV Systems Interconnected with Primary Feeders)

  • 김병기;김소희;유경상;노대석
    • 한국융합학회논문지
    • /
    • 제2권4호
    • /
    • pp.29-37
    • /
    • 2011
  • 종래의 배전계통에 있어서의 전력조류는 변전소에서 선로말단을 향한 단 방향이었지만, 신에너지전원(분산전원)이 연계된 배전계통의 경우에는 그 출력용량의 여부에 따라 양방향의 전력조류가 발생할 가능성이 있어, 계통운용상 여러 가지의 문제점이 야기될 수 있다. 분산전원은 대규모전원의 보완적 역할과 배전선로 상의 국부적 부하 감당 역할을 부과하여 그의 적극적 활용을 꾀하기 위해서는, 분산전원으로부터 배전계통에 전력을 공급하는 역 조류의 기능을 허용할 수 있는 양방향 보호협조방식의 체제를 확립할 필요가 있다. 따라서 본 연구에서는 분산전원 연계에 따른 보호협조 기본 방안과 부하절체 운전에 따른 보호협조 방안, 변압기결선에 따른 보호협조 방안 등에 대한 알고리즘을 제시하였다. 또한, 이론적인 계산법(대칭좌표법)과 MATLAB/SIMULINK에 의하여 실 계통에서의 양방향 보호협조에 관련된 문제점을 분석하고, 해결방안을 제시하였다.