• Title/Summary/Keyword: Power Transformer Fault

Search Result 260, Processing Time 0.03 seconds

개선된 자속구속형 전류제한기의 동작 특성 분석

  • Kim, Yong-Jin;Du, Ho-Ik;Kim, Min-Ju;Lee, Dong-Hyeok;Han, Byeong-Seong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.215-215
    • /
    • 2009
  • Improved flux-lock type superconducting fault current limiter(SFCL) is composed of a series transformer and superconducting unit of the YBCO coated conductor. The primary and secondary coils in the transformer were wound in series each other through an iron core and the YBCO coated conductor was connected with secondary coil in parallel. In this paper, we investigated the current limiting characteristics through initial line current after fault initiation. through the analysis, it was shown that the smaller initial line current is superior to current limiting characteristics and a point of view of power burden of the YBCO coated conductor.

  • PDF

Protective Algorithm for Transformer Using Nuro-Fuzzy (뉴로-퍼지를 이용한 변기 보호 알고리즘)

  • Lee, Myoung-Rhun;Lee, Jong-Beom;Hong, Dong-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.299-302
    • /
    • 2002
  • The second harmonic component is commonly used for blocking differential relay in Power transformers. However it is difficult to distinguish between inrush and internal winding fault with differential current protective relaying. This paper proposed a new method using nuro-fuzzy. The used data in nuro-fuzzy algorithm are 3-phase primary voltage and fundamental harmonic of differential current. Various states of transformer are simulated using BCTRAN and HYSDAT of EMTP. As a result of applying the algorithm in various cases, the correct discrimination between internal winding fault and inrush performed.

  • PDF

Bus Reconfiguration Strategy Based on Local Minimum Tree Search for the Event Processing of Automated Distribution Substations

  • Ko Yun-Seok
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.2
    • /
    • pp.177-185
    • /
    • 2005
  • This paper proposes an expert system that can enhance the accuracy of real-time bus reconfiguration strategy by adopting the local minimum tree search method and that can minimize the spreading effect of the fault by considering the operating condition when a main transformer fault occurs in an automated substation. The local minimum tree search method is used to expand the best-first search method. This method has the advantage that it can improve the solution performance within the limits of the real-time condition. The inference strategy proposed expert system consists of two stages. The first stage determines the switching candidate set by searching possible switching candidates starting from the main transformer or busbar related to the event. The second stage determines the rational real-time bus reconfiguration strategy based on heuristic rules from the obtained switching candidate set. Also, this paper proposes generalized distribution substation modeling using graph theory, and a substation database based on the study results is designed.

Protecive Algorithm for Transformer Using Nuro-Fuzzy System based on HCM (HCM기반 뉴로-교지 시스템을 이용한 변압기 보호 알고리즘)

  • Lee, Myoung-Rhun;Lee, Jong-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.552-554
    • /
    • 2003
  • The second harmonic component is commonly used for blocking differential relay in power transformers. However, it is difficult to distinguish between inrush and internal winding fault with differential current protective relaying. This paper proposed a new method using Nuro-Fuzzy System based on HCM(Hard C-Means). The proposed system is more objective and systematic than existing model. The data used in input are 3-phase primary voltage and fundamental harmonic of differential current. Various states of transformer are simulated using BCTRAN and HYSDAT of EMTP. As a result of the application of algorithm in various cases, the exact discrimination between internal winding fault and inrush is performed.

  • PDF

A Study on Performance of Current Transformer in High Voltage System (고압계통 변류기 동작 특성 검토)

  • Choi, Ki-Yeol;Lee, Duck-Soo;Park, Moon-Bin;Kim, Hee-Taek;Chang, Ki-Poong
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.5-7
    • /
    • 2006
  • Current transformers(CTs) whose rating is selected per a full load current of a feeder in high voltage system can be easily saturated due to high fault current that may be several hundred times of the full load current of the feeder. However, the protective relay shall operate properly at the fault without mis-operation under the CT saturation. So, in selecting the CT rating, it is necessary to consider the behaviour of CT and a performance of protection scheme in condition where CT can be saturated. In this paper, a performance of CT and a degree of saturation are studied and verified whether its ratings are proper for the operation of the protective relay.

  • PDF

The conceptual design and analysts of three phase superconducting fault current limiter (일체형 삼상 고온 초전도 한류기의 단락 특성 해석)

  • Lee, Sueng-Je;Lee, Chan-Joo;Lee, Chang-Yul;Jang, My-Hye;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 1998.07a
    • /
    • pp.94-97
    • /
    • 1998
  • The conceptual design of integrated three phase superconducting fault current limiter (SFCL) is presented. And through simulation of power system where this SFCL is installed, the characteristics of this SFCL is analyzed. It is like three-phase transformer. So it has the same characteristics with inductive single phase SFCL. But it has more merits than single phase SFCL. Differently to single phase SFCL, integrated three phase SFCL induces impedance at all phase by any single phase fault to protect the power system more safely.

  • PDF

Current Limiting Characteristics of transformer type SFCL using neutral line (중성점을 이용한 변압기형 초전도 한류기의 전류제한 특성 분석)

  • Cho, Yong-Sun;Choi, Hyo-Sang;Park, Hyoung-Min;Lee, Ju-Hyoung;Jung, Byung-Ik
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.2090-2091
    • /
    • 2007
  • We investigated the characteristics of transformer type SFCL with neutral line. The transformer type SFCL having neutral line has achieved the simultaneous quench because the secondary winding has acted as parallel reactor. The fault current of SFCL was limited according to ratio of turn number between primary and secondary windings. Therefore, the power burden of superconducting element can be reduced by reduction of ratio of turn number between primary and secondary windings. As a result, we could expect reduction of it's volume in the transformer type SFCL.

  • PDF

Operation and Configurgation of Superconducting Machines and Devices in Utility System (초전도전력설비의 구성 및 운전)

  • 홍원표;이원규;곽희로
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.116-121
    • /
    • 1996
  • An image of future power system which has introduced superconducting generator, cable, transformer, fault current limiter, SMES and so on is presented. Conceptual designs of each SC machines and devices are carried out. The SC cable and SFCL utilize the high Tc superconductor(HTS) cooled by liquid $N_2$Other devices use low temperature superconducting cooled by He. The SC power system models are proposed detailedly. In viewpoint of the operation and control SC power system, The concrete design direction and effective role of each SC apparatus are investigated. In this paper, it is pointed that superconducting fault limiters(SFCLs) should play an important part of the quenching current level coordination to prevent the other SC devices from quenching. Finially, SFCL are also expected to he very effective to introduce flexibility of power system configuration and operation due to their possibility to enhance transient stability and reduce short circuit current.

  • PDF

The construction of 3-phase 90 MVA short-time withstand current testing facilities (3상 90 MVA 단시간전류시험 설비 구축)

  • Suh, Yoon-Taek;Kim, Yong-Sik;Yun, Hak-Dong;Kim, Maeng-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.700-702
    • /
    • 2005
  • The most electrical apparatus should be able to withstand short-time current and peak current during a specified short time until circuit breakers have interrupted fault current. It defines the short-time withstand ability of electric a apparatus to be remain for a time interval under high fault current conditions. It is specified by both dynamic ability and thermal capability. KERI(Korea Electrotechlology Research Institute) recently constructed the new short-time current and low voltage short circuit testing facilities. This paper shows short- circuit calculation of transformer and describes high current measuring system, and evaluate the result of short-time withstand test used in $3{\phi}$ 90MVA short-time current testing facilities.

  • PDF

A Lecture Note on PU Method thru Calculation of a Simple DC Circuit and Voltage/Fault Analysis of Industrial Power Systems using Actual Data (PU법에 의한 DC 회로계산 및 실계통 데이터를 이용한 전압강하/고장계산 방법)

  • Lee, Sang-Joong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.45-54
    • /
    • 2014
  • This paper presents a lecture note of pu method for power system analysis. The author tries to help students in class better understand the fundamental of pu calculation using a very simple DC circuit. And a voltage drop calculation by pu method for a distribution system is given to help understand the importance of the vector reference in AC circuit analysis. A short current calculation by pu method for a power system with a generator, transformer and transmission line is also presented to show how pu calculation can be applied to real power systems, in which all the data are the ones currently being used by KEPCO and other industrial sites.