• 제목/요약/키워드: Power System Oscillations

검색결과 120건 처리시간 0.025초

PSSs and SVC Damping Controllers Design to Mitigate Low Frequency Oscillations Problem in a Multi-machine Power System

  • Darabian, Mohsen;Jalilvand, Abolfazl
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권6호
    • /
    • pp.1873-1881
    • /
    • 2014
  • This paper deals with the design of multi-machine power system stabilizers (PSSs) and Static var compensator (SVC) using Modified shuffled frog leaping algorithm (MSFLA). The effectiveness of the proposed scheme for optimal setting of the PSSs and SVC controllers has been attended. The PSSs and SVC controllers designing is converted to an optimization problem in which the speed deviations between generators are involved. In order to compare the capability of PSS and SVC, they are designed independently once, and in a coordinated mode once again. The proposed method is applied on a multi-machine power system under different operating conditions and disturbances to confirm the effectiveness of it. The results of tuned PSS controller based on MSFLA (MSFLAPSS) and tuned SVC controller based on MSFLA (MSFLA SVC) are compared with the Strength pareto evolutionary algorithm (SPEA) and Particle swarm optimization (PSO) based optimized PSS and SVC through some performance to reveal its strong performance.

적응진화연산을 이용한 퍼지-전력계통안정화장치 설계 (A Design of Fuzzy Power System Stabilizer using Adaptive Evolutionary Computation)

  • 황기현;박준호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제48권6호
    • /
    • pp.704-711
    • /
    • 1999
  • This paper presents a design of fuzzy power system stabilizer (FPSS) using adaptive evolutionary computation (AEC). We have proposed an adaptive evolutionary algorithm which uses a genetic algorithm (GA) and an evolution strategy (ES) in an adaptive manner in order to take merits of two different evolutionary computations. FPSS shows better control performances than conventional power system stabilizer (CPSS) in three-phase fault with heavy load which is used when tuning FPSS. To show the robustness of the proposed FPSS, it is appliedto damp the low frequency oscillations caused by disturbances such as three-phase fault with normal and light load, the angle deviation of generator with normal and light load and the angle deviation of generator with heavy load. Proposed FPSS shows better robustness than CPSS.

  • PDF

Effects of Wind Generation Uncertainty and Volatility on Power System Small Signal Stability

  • Shi, Li-Bao;Kang, Li;Yao, Liang-Zhong;Qin, Shi-Yao;Wang, Rui-Ming;Zhang, Jin-Ping
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.60-70
    • /
    • 2014
  • This paper discusses the impacts of large scale grid-connected wind farm equipped with permanent magnet synchronous generator (PMSG) on power system small signal stability (SSS) incorporating wind generation uncertainty and volatility. Firstly, a practical simplified PMSG model with rotor-flux-oriented control strategy applied is derived. In modeling PMSG generator side converter, the generator-voltage-oriented control strategy is utilized to implement the decoupled control of active and reactive power output. In modeling PMSG grid side converter, the grid-voltage-oriented control strategy is applied to realize the control of DC link voltage and the reactive power regulation. Based on the Weibull distribution of wind speed, the Monte Carlo simulation technique based is carried out on the IEEE 16-generator-68-bus test system as benchmark to study the impacts of wind generation uncertainty and volatility on small signal stability. Finally, some preliminary conclusions and comments are given.

Nonlinear Feedback Linearization-Full Order Observer/Sliding Mode Controller Design for Improving Transient Stability in a Power System

  • Lee, Sang-Seung;Park, Jong-Keun
    • Journal of Electrical Engineering and information Science
    • /
    • 제3권2호
    • /
    • pp.184-192
    • /
    • 1998
  • In this paper, we present a nonlinear feedback linearization-full order observer/sliding mode controller (NFL-FOO/SMC), to obtain smmoth control as a linearized controller in a linear system (or to cancel the nonlinearity in a nonlinear system), and to solve the problem of the unmeasurable state variables as in the conventional SMC. The proposed controller is obtained by combining the nonlinear feedback linearization-sliding mode control (NFL-SMC) with the full order observer (FOO)and eliminates the need to measure all the state variables in the traditional SMC. The proposed controller is applied to the nonlinear power system stabilizer (PSS) for damping oscillations in a power system. The effectiveness of the proposed controller is verified by the nonlinear time-domain simulations in case of a 3-cycle line-to-ground fault and in case of the parameter variation for the AVR gain K\ulcorner and for the inertia moment M.

  • PDF

HVDC 연계 시스템의 전력계통 안정화 장치와 전력변환기 적정 파라미터 선정에 관한 연구 (A Study on the Optimal Parameter Selection of a Power System Stabilizer and Power Converters for HVDC Linked System)

  • 조의상;김경철;최홍규
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2001년도 학술대회논문집
    • /
    • pp.65-72
    • /
    • 2001
  • Power system stabilizer act efficiently to damp the electromechanical oscillations in interconnected power systems. This paper presents an algorithm for the optimal parameter selection of a power system stabilizer in two-area power systems with a series HVDC link. This method is one of the classical techniques by allocating properly pole-zero positions to fit as closely as desired the ideal phase lead between the voltage reference and the generator electrical power and by changing the gain to produce a necessary damping torque over the matched frequency range. Control of HVDC converter and inverter are used a constant current loop. Proper parameters of PI controllers are obtain based on the Root-locus technique in other to have sufficient speed and stability margin to cope with charging reference values and disturbance. The small signal stability arid transient stability studies using the PSS parameters obtained from this method show that a natural oscillation frequency of the studycase system is adequately damped. Also the simulation results using the HVDC converter and inverter parameters obtained from this proposed method show proper current control characteristics. The simulation used in the paper was performed by the Power System Toolbox software program based on MATLAB.

  • PDF

실수형 유전알고리즘을 이용한 전력계통 퍼지안정화장치의 설계 (Design of Fuzzy Power System Stabilizer using Real-coding Genetic Algorithm)

  • 이종규;권순일;김성신;박준호;황기현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.134-136
    • /
    • 2001
  • This paper describes the application of Fuzzy Power System Stabilizer(FPSS) for improving dynamic stability of power system. The Real-coding Genetic Algorithm(RGA) was applied to optimize gains of the inputs and outputs of the FPSS. The effectiveness of the proposed FPSS was demonstrated by simulation studies for single-machine infinite system. To show the superiority of the proposed FPSS, its performances were compared with those of Conventional Power System Stabilizer(CPSS) The proposed FPSS showed better control performances than the CPSS in three-phase ground fault under a normal load which was system condition in tuning FPSS. To show the robustness of the proposed FPSS, it was applied to damp the low frequency oscillations caused by disturbances such as three-phase ground fault under heavy and light load conditions. The proposed FPSS showed better performance than CPSS in terms of the settling time and damping effect for power system operation condition.

  • PDF

HVDC 연계 시스템의 전력계통 안정화 장치의 적정 파라메터 선정에 관한 연구 (A Study on the Optimal Parameter Selection of a Power System Stabilizer for HVDC Linked System)

  • 김경철;최홍규;최병숙;강태은;고영곤
    • 조명전기설비학회논문지
    • /
    • 제15권5호
    • /
    • pp.81-89
    • /
    • 2001
  • 전력 계통 안정화 장치는 전력시스템에 외란이 발생했을 때 저주파수 동요현상을 효과적으로 저감하는 역할을 한다. 본 논문은 제주-해난 HVDC로 연계된 전력시스템에 설치된 PSS의 적정 파라메커 선정이론을 다루었다. 사용한 알고리즘은 위상지연을 적절한 극좌표 이동법으로 보상하고 설정된 댐핑계수가 되도록 이득계수를 구하는 방법이다. PSS 효과를 검증하기 위해 동태 및 과도안정도를 PSS 설치 전과 후로 비교하였다. MATLAB을 근거로 한 PST 프로그램을 사용하여 사례연구 시스템에 적용한 시뮬레이션 결과는 PSS를 설치하므로써 전력시스템이 안정화되어 만족할 만큼의 댐핑효과를 보았다.

  • PDF

New Serial and Parallel Sin+Cos PSS1A PSS Design and Analysis

  • Lee Sang-Seung;Li Shan-Ying;Jang Gwang-Soo;Park Jong-Keun;Moon Seung-Il;Yoon Yong-Tae
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권4호
    • /
    • pp.378-384
    • /
    • 2005
  • This paper proposes a new series and parallel Sin+Cos PSS (power system stabilizer) for the purpose of improving the existing PSS1A's performance. The purpose of the PSS is to enhance the damping of power system oscillations through injection of auxiliary signals for an excitation control terminal. The proposed series and parallel Sin+Cos PSS is connected adding the Sin+Cos terms additionally with the serial and parallel connection in a conventional PSS1A. The proposed controller is aimed at considering the damping of oscillation when it changes parameter fluctuations or operational load variations in a power system. The electric power system used is the KEPCO system and the voltage of the power transmission line is 154kV and 345kV. The PSCAD/EMTDC package is used to authorize the effect of the proposed controller. Simulations were shown by and compared with the waveforms for frequency, voltage and electric power.

동시안정화를 이용한 저차원 극배치 전력계통안정화장치 설계 (Design of a Low-order Pole Placement Power System Stabilizer Using Simultaneous Stabilization)

  • 김석주;이종무;권순만
    • 전기학회논문지
    • /
    • 제57권10호
    • /
    • pp.1708-1712
    • /
    • 2008
  • This paper describes a linear matrix inequality (LMI) approach to the design of robust low-order power system stabilizers (PSSs), which are used to damp out local-mode oscillations of synchronous generators. The performance of a PSS is expressed as the location of the closed-loop poles, and a single fixed-gain pole-placement controller is synthesized for a wide range of operating conditions. The synthesis results in simultaneous regional pole-placement stabilization. and is formulated as an LMI feasibility problem with a rank condition. A penalty method is applied to solve the rank-constrained LMI problem. Numerical experiments with a single-machine connected to an infinite bus system were performed to demonstrate the proposed method.

CANDU-6 열수송 계통의 유동 진동감쇠에 의한 유동안정성 연구 (An Investigation on Flow Stability with Damping of Flow Oscillations in CANDU-6 heat Transport System)

  • 김태한;심우건;한상구;정종식;김선철
    • 소음진동
    • /
    • 제6권2호
    • /
    • pp.163-177
    • /
    • 1996
  • An investigation on thermohydraulic stability of flow oscillations in the CANada Deuterium Uranium-600(CANDU-6) heat transport system has been conducted. Flow oscillations in reactor coolant loops, comprising two heat sources and two heat sinks in series, are possibly caused by the response of the pressure to extraction of fluid in two-phase region. This response consists of two contributions, one arising from mass and another from enthalpy change in the two-phase region. The system computer code used in the investigation os SOPHT, which is capable of simulating steady states as well as transients with varying boundary conditions. The model was derived by linearizing and solving one-dimensional, homogeneous single- and two-phase flow conservation equations. The mass, energy and momentum equations with boundary conditions are set up throughout the system in matrix form based on a node-link structure. Loop stability was studied under full power conditions with interconnecting the two compressible two phase regions in the figure-of-eight circuit. The dominant function of the interconnecting pipe is the transfer of mass between the two-phase regions. Parametric survey of loop stability characteristics, i. e., damping ratio and period, has been made as a function of geometrical parameters of the interconnection line such as diameter, length, height and orifice flow coefficient. The stability characteristics with interconnection line has been clarified to provide a simple criterion to be used as a guide in scaling of the pipe.

  • PDF