• Title/Summary/Keyword: Power Supply System

Search Result 3,259, Processing Time 0.036 seconds

A Study on the Characteristics and Fabrication of Switching Power Module for High Efficiency and Small Size of Power Supply System (전원장치의 소형화와 고효율화를 위한 스위칭 파워 모듈의 제작과 특성에 관한 연구)

  • Kim, Chan;Jeon, Eui-Seok;Kang, Do-Young;Kim, Byung-Cheul
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.758-761
    • /
    • 2003
  • We have designed 5 V/500 mA transless type power module by using semiconductor switching technique, key technique for small size of power supply system. The power module is suitable to a small sized electronic system using a single power supply. It is composed of switching circuit using voltage drop type chopper method, control circuit, voltage detect circuit, and constant voltage circuit, and is fabricated to hybrid-IC type. The switching regulator power supply circuit, designed in this study, has satisfied the electrical characteristics of 5 V/500 mA transless type power module.

  • PDF

A Study of assessment criteria and reliability improvement for power supply of electrodeless fluorescent lamp (고효율 무전극형광등용 전원장치의 평가기준 및 신뢰성향상 연구)

  • 함중걸;신종욱
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.181-185
    • /
    • 2002
  • This paper gives an assessment criteria and reliability improvement for high frequency power supply of high efficacy electrodeless fluorescent lamp. The electrodeless fluorescent lamp system consist of electrodeless fluorescent lamp, high frequency power supply and lighting fixtures. The high frequency power supply has a shortest life at the system. Therefore It is need to assess the Failure Rate or Mean Time To Failure(MTTF) for the high frequency power supply of electrodeless fluorescent lamp system and improve the reliability at design. We suggest the assessment criteria and improve methods of the reliability on the design basis for the electodeless fluorescent system.

  • PDF

A Study of Generator Excitation System for first Power Supply to gird line (가스터빈 시송전 발전기 여자시스템에 관한 연구)

  • Ryu, Ho-Seon;Lim, Ick-Hun
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1193-1194
    • /
    • 2011
  • We performed commissioning of redundant digital excitation system for gas turbine generator. One of its issues is first power supply test to gird line when it was compared with the other commissioning. If blackout will be happened, a few of start power plants must supply power to grid line. And then generator must increase voltage and real power slowly for line charge. The trial product was installed and successfully operated at a 100MW power plant after commissioning.

  • PDF

The Development of Industrial Magnetron Power Supply (산업용 마그네트론 구동전원 개발)

  • Ryoo, Hong-Je;Kim, Jong-Su;Kim, Su-Jin;Kytykh, D.
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.222-223
    • /
    • 2006
  • In this paper, the design of power supply for high power magnetron system is studied. For magnetron drive, three kinds of power supply is required for main high voltage, magnet and heating filament. Detail design was accomplished with basic simulation and real system is developing based on basic design.

  • PDF

Remote control of ship's emergency lighting system (선박 비상조명 시스템의 원격제어)

  • Lim, Hyun-Jung;Yang, Hyun-Suk;Kim, Kun-Woo;Lee, Sung-Geun;Kim, Yoon-Sik
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.252-253
    • /
    • 2005
  • This paper describes a improvement of power control characteristics of ship's emergency lighting power supply(SELPS), that power factor(PF) is improved and electric power is controlled extensively, and power ON-OFF is controlled and system parameter monitored in remote distance by PC serial communication.

  • PDF

Development of the 120kW Class MPC Power Supply for DeNOx and DeSox System (120kW급 탈황탈질용 MPC전원장치 개발)

  • Kim, Soo-Hong;Kwon, Byung-Ki
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.237-239
    • /
    • 2009
  • This paper presents a new developed 160kV-120kW Class MPC (magnetic pulse compressor) power supply for DeNOx, DeSOx system. The circuit consists of N-series connected CCPS (capacitor charging power supply) and MPC Tank. The MPC power supply developed compared to the conventional LC resonant type has many advantage, it was verified reliability of a product by module, simulator and tank connection test. Now, the developed MPC power supply is installed POSCO sintering plant for DeSOx, DeNOx system.

  • PDF

Study on the High and High Voltage 35 kW, 50 kV Inverter Power Supply (대출력 고전압 35 kW, 50 kV 인버터 전원장치 개발에 관한 연구)

  • Son, Yoon-Gyu;Jang, Sung-Duck;Oh, Jong-Seok;Cho, Moo-Hyun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.11
    • /
    • pp.628-634
    • /
    • 2002
  • A capacitor-charging power supply using high frequency inverter technology is strongly recommended for the charging section of the pulsed power supplies. A high frequency inverter swiching makes the overall system size small. The command-charging feature can guarantee the higher reliability of switching function. The protection circuit can be easily included in the system and the good regulation of charging voltage can be acieved by the feedback system. Several modules can be stacked to supply required output power and a failed module can be easily replaced. A 50-kV, 35-kW capacitor charging power supply is developed. In this paper the detailed design and test results of a prototype unit are presented.

A Study on the Operation Method of Emergency Power System with Reserved Firefighting Power (RFP) (소방전원보존형 발전기(RFP)의 작동 방법에 관한 연구)

  • Lee, Won-Kang;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.29-34
    • /
    • 2012
  • The purpose of this study is to propose an effective operating method of a power generator used by the Emergency Power System in case of a simultaneous fire and of the limitations of the interlock system the power supply from the emergency power generator. On the Emergency Power System with Reserved Fire-fighting Power (RFP), in case of an overload, the collective control Emergency Power System signals the main circuit breaker to shut off the supply to the emergency load, leaving the supply to the firefighting load uninterrupted to the end. The sequential control Emergency Power System signals the firefighting power supply to shut off the fire stage of the emergency load and continues to monitor the power supply. If an overload happens again from increased firefighting load, the sequential control Emergency Power System sends a secondary signal to shut down the second stage of the emergency load.

A HIGH VOLTAGE DC POWER SUPPLY SUITABLE FOR AN ION SOURCE

  • Nho, Eui-Cheol;Kim, In-Dong
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.436-441
    • /
    • 1998
  • This paper proposes an novel dc power supply using modified multilevel ac/dc converter. The output voltage of the power supply can be disconnected from and reapplied to the load rapidly. Therefore the power supply is suitable for a load having frequent short circuit such as ion source. The proposed scheme improves the performance, efficiency, and reliability and reduces the cost of the conventional power supply system for an ion beam acceleration.

  • PDF

A Study on the Improvement of Performance of Power Supply for Ship's Emergency Lighting System (선박 비상조명용 전원장치의 성능개선)

  • Yang Hyun-Suk;Lee Su-Hun;Jeong Tae-Sun;Lee Sung-Geun;Kim Yoon-Sik
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.822-825
    • /
    • 2004
  • This paper describes the improvement of performance of power supply for ship's emergency lighting system(SELS). Proposed system is composed of power factor correction (PFC) circuit, emergency power supply system (EPSS), half bridge(HB) inverter, fluorescent lamp(FL) starting circuit and microprocessor control system. Experimental works using proposed system confirm that speedy and stable power to be supplied when main power source cut-off, compared with conventional relay type, and control power factor up to $97.5[\%]$ and input power up to $35.0[\%]$ by adjusting of pulse frequency of the HB inverter.

  • PDF