디지털변전소 엔지니어링 툴 구현을 위한 IEC 61850 국제규격 기반의 변전소 토폴로지 표현에 관한 연구 (A Study on Description of IEC 61850 based Substation Topology for Implementing the Engineering Tool of Digital Substation)

  • 이남호;안용호;장병태
    • 조명전기설비학회논문지
    • /
    • 제29권9호
    • /
    • pp.23-32
    • /
    • 2015
  • In order to complete engineering works of the digital substation, Both Data transmission among a variety of IEDs and HMIs, and single line diagram of the substation might be done based on XML documents published in IEC 61850 international standards. This kind of XML based engineering process for the digital substation must be implemented not by manual written work but by the engineering tool using a computer. But most of the engineering tools do not support system based engineering works such as single line diagram of the substation but have only function to set IEDs as single device unit. Accordingly, this paper presents a new design method of the system based engineering description applicable to real IEC 61850 based substation through analyzing the current international standard and its sampled engineering file, and shows implementation of the engineering tool of the digital substation with the result of this study.

상정사고를 고려한 배전용 변전소 신,증설 계획 수립 (Planning for Construction and Expanding of Distribution Substation Considering Contingency)

  • 최상봉;김대경;정성환
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권7호
    • /
    • pp.303-308
    • /
    • 2001
  • This paper presents algorithm to plan construction and expanding of substation considering contingency accidents by proposing utilization factor according to configuration of substation bank system. In this paper, firstly, proper sphere of supply area by each district which could be standardized with respect to its supply capacity is established under assumption of long term load forecasting. Secondly, goal of utilization ratio based on configuration of substation bank was set to keep reliability by remaining sound bank when it happen to one bank accidents. Finally, it is set up for optimal construction and expanding of substation considering economy and reliability simultaneously about substation to exceed these ratio. To verify proposed algorithm, at first, after adopting a part of Kangnam area in Seoul as area for testing, it is divided into several regions for this area according to power branches of power utility. Secondly, by deriving correlation factor between load demand and economic indicators in these region respectively, the regional load forecasting was performed with economic growth and city plan scenario. Finally, based on the predicted load demand by region and land use data which is identified from air-photographic, the load demand by district was predicted. Also, planning for substation considering contingency is formulated to expand taking into account computing utilization factor which is based on configuration of substation bank respectively.

  • PDF

전기철도 차량기지 변전소의 실시간 무효전력/역률 보상설비 적용에 따른 전력품질 개선에 관한 연구 (A Study on Improving Power Quality by Real-time Reactive Power/Power Factor Compensating Equipment at Substation in Marshalling Yard)

  • 박수철;송중호
    • 조명전기설비학회논문지
    • /
    • 제20권10호
    • /
    • pp.58-67
    • /
    • 2006
  • 본 논문에서는 전기철도 차량기지 변전소의 전력품질을 개선하기 위한 실시간 무효전력/역률 보상설비를 제안하였으며 실제 차량기지에 적용하기 위한 최적의 용량을 제시하였다. 이를 위하여 현재 상용화된 여러 종류의 실시간 무효전력/역률 보상설비를 소개하였고 이 중에 전기철도 차량기지 변전소의 부하 특성에 가장 적합한 보상설비인 SVG(Static Var Generator)를 제시하였다. 제시된 SVG는 PSIM을 사용하여 간이 모의 시스템으로 구현되었으며 이를 통한 기본적인 보상원리와 모의 결과를 기술하였다. 실제 차량기지에 적용하기 위한 최적의 용량 설계는 실제 측정된 차량기지 변전소의 전력품질 데이터를 기초로 설계되어 졌으며 보상효과 및 경제적인 측면이 고려된 용량으로 제시되었다. 최종적으로 전압형 인버터와 직류 커패시터로 구성된 실시간 무효전력/역률 보상설비를 통한 실제 전기철도 차량기지 변전소의 전력품질 개선에 대하여도 기술되었다.

변전소 건설로 인한 자기장 노출범위설정에 관한 연구 (Study for Exposure Limits of Magnetic Fields in the Transformer Substation)

  • 전인수
    • 환경영향평가
    • /
    • 제14권4호
    • /
    • pp.195-202
    • /
    • 2005
  • The health risks from the magnetic fields exposure have been brought out difficulties in the construction of transformer substation. According to several epidemiologic studies and the relevant international organizations, magnetic fields should not exceed the exposure limits of 3mG for the people living near electric power lines. The rigid regulation of the exposure levels for the elementary school and residental areas has been established already in Switzerland and Italy. Since 1998, the environmental impact assessment system in Korea has been reviewed for power-frequency magnetic field by precautionary policies. In this study, the possible application of Prior Environmental Performance Review System for the transformer substation was reviewed from the points of the properties of the powerfrequency magnetic fields. The ranges and survey methods of the assessment for the transformer substation were proposed. The ranges of magnetic fields was between 300m to 500m for the 345kV transformer substation. It is necessary to develop further specific assessment methods for various high-voltage transformer substations.

변전설비 간 상호작용을 고려한 지진응답해석 (Seismic Analysis of Substation Facilities Considering Interaction Effect)

  • 장정범;황경민;서용표;이근직
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.605-612
    • /
    • 2006
  • 765kV substation facilities are most important as electric power supply network in the 21 century. So, in order to prevent interruption of electric power supply under earthquake, 765kV substation facilities have to secure the safety against the earthquake. However, even though each substation facility is interconnected mutually, seismic interaction effect doesn't be considered in the initial design. Therefore, seismic capacity evaluation of 765kV substation facilities is carried out considering the seismic interaction effect on a basis of seismic design criteria for Korean transmission and substation facilities.

  • PDF

송변전지리정보시스템(TGIS) 개발 추진현황 및 향후과제 (Development of Transmission & Substation Geographic Information System)

  • 안태형;문봉수;권오형
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.575-577
    • /
    • 2005
  • KEPCO has developed Transmission & Substation Geographic Information System(TGIS) since 2000. TGIS is the system for the management of transmission and substation facilities on the geographic basis. This paper provides a brief introduction to TGIS.

  • PDF

Gigabit Ethernet Based Substation

  • Yang, Hyo-Sik;Raza, Ali;Park, Min-Woo;Kim, Sang-Sig;Jang, Hyuk-Soo;Lee, Myung-Ho;Kwon, Dong-Seop;Jang, Byung-Tae
    • Journal of Power Electronics
    • /
    • 제9권1호
    • /
    • pp.100-108
    • /
    • 2009
  • Designing communication architecture for substation automation is a challenging and subtle task for visualizing substations in the digital world under the umbrella of IEC61850. Communication paradigms for substation automation are of critical importance because of two reasons; the communication arena is changing daily and opts for convenience and simple deployment at a lower migration cost and interoperability is one of the core constrains of IEC61850 for substation automation. This paper presents an analysis and outline of the crucial need for the deployment of Gigabit Ethernet in substations and also presents suggestions on how Ethernet technology can help in substation automation. Ethernet is one of the most pervasive communication technologies available and can provide a long term solution in the changing arena of communication. We have performed simulations in NS-2 to prove that our suggested communication paradigm is optimal in various regards with consideration of the constraints imposed by IEC61850.

전력계통 제어를 위한 변전소 AC/DC 겸용 비상전원에 관한 연구 (A study of AC/DC combined emergency source for power system control)

  • 전범배;이형한;김창곤;안보순;윤기섭;정종기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.135-138
    • /
    • 2005
  • This paper focuses on emergency source and control of substation against the consequence of power system breakdown or outage. the aim of the paper is to provide ideas and guidance concerning methods of using AC/DC combined emergency source for power system control to restore power system after unforseen events, such as outages caused by natural disaster. so the emergency source and lamp is very important for restoration control of substation after outage. therefore, this paper proposes countermeasure and method for security of substation emergency source and lamp which is restored at breakdown.

  • PDF

765kV 변전소 시운전에 관한 고찰 (Consideration on the trial operation of 765kV substation)

  • 변강;정시환;박근원;이상면;최만식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.29-31
    • /
    • 2002
  • Purpose of the 765kV trial operation conducted for the first time in our country are performance verification of domestic developed equipment(765kV M.Tr, GIS,etc) and extraction of problem in advance to commercial operation and cultivation of operation ability. The trial operation of 765kV substation was finished successfully under the positive supports of institutes. manufactures. and constructers. It is expected that extraction of problems in advance and accumulation of operation techniques through the trial operation of 765kV substation will be contributed largly to the realization of the without a hitch operation of 765kV system.

  • PDF

EMTP/RV를 이용한 22.9kV GIS 모델링과 과도회복전압 해석 (22.9kV GIS Modeling and Transient Recovery Voltage Analysis Using EMTP/RV)

  • 정태영;백영식;정기석;박지호;서규석
    • 전기학회논문지
    • /
    • 제59권7호
    • /
    • pp.1199-1205
    • /
    • 2010
  • The recent power system is required to a large size of facilities and high power technology according to increasing power demand. However, it could lead to spoiling the beauty of city and environment problem. The miniaturized facilities with large capacity such as GIS have been required in recent power system. The GIS(Gas Insulated Substation) using the SF6 insulation gas enables to miniaturize facilities with large capacity with high insulation performance. However, the substation installed GIS has required to new design model which is different from the conventional substation. The TRV(Transient Recovery Voltage) analysis on simple circuit may applied by differential equation. However, in case of relatively complicated system, EMTP(Electro Magnetic Transients Program) mainly has been used to design and simulate for transient analysis. This paper mainly design the 22.9 kV GIS system and analyze the transient recovery voltage of main circuit breaker using EMTP/RV. It also enables to easily design the other substation installed GIS with same maker and voltage level because the proposed GIS model consists of separated modules such as busbar, circuit breaker, bushing, CT, PT etc. Eventually, it contributes to comfortably compare the interrupting performance of circuit breaker and system TRV corresponding to the substation system configuration.