• 제목/요약/키워드: Power Saving Mode

검색결과 125건 처리시간 0.027초

NON CONVENTIONAL METHOD FOR SOFT STARTING OF THREE PHASE INDUCTION MOTORS

  • Ahmed Nabil A.;Kim Sung-Jun;Suh Ki-Young;Kown Soon-Kurl;Lee Hyun-Woo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 추계학술대회 논문집
    • /
    • pp.27-31
    • /
    • 2004
  • This paper presents a nonconventional method for oft starting of three-phase induction motors, which achieved by flux weakening technique. flux weakening is not done by reducing the applied voltage as in the conventional methods, Flus weakening is achieved y increasing the supply frequency over the rated value while the voltage amplitude is kept constant. This method has advantage of reducing the stress on the electrical and mechanical systems. The feasibility of this basic idea has been confirmed through investigating the starting transient corresponding to this mode of operation. For this purpose, a rigorous state space mathematical model has been developed and simulated. The validity of the proposed method through the results from the mathematical model have been confirmed experimentally.

  • PDF

속도제어-정용량 펌프를 사용하는 실린더-부하계의 에너지절약-부하감지형 경로제어 (Path Control with Energy-Saving Load-Sensing for a Cylinder-Load System Using Speed-Controlled Fixed Displacement Pump)

  • 조승호
    • 유공압시스템학회논문집
    • /
    • 제6권3호
    • /
    • pp.16-22
    • /
    • 2009
  • This paper deals with the issue of robust position tracking control and energy-saving control for a valve-controlled cylinder system using speed-controlled fixed displacement pump. The whole feedback control system is composed of a pair of interconnected subsystems, that is, valve-controlled cylinder system and load-sensing control system. From experiments it is shown that position tracking control in the load sensing control system can accomplish significant reduction in input energy to pump comparing to a conventional valve-controlled cylinder system, while exhibiting the same position tracking control accuracy.

  • PDF

서버 클러스터 환경에서 에너지 절약을 위한 동적 서버 전원 모드 제어 (A Dynamic Server Power Mode Control for Saving Energy in a Server Cluster Environment)

  • 김호연;함치환;곽후근;권희웅;김영종;정규식
    • 정보처리학회논문지C
    • /
    • 제19C권2호
    • /
    • pp.135-144
    • /
    • 2012
  • 기존의 서버 클러스터 환경에서는 모든 서버가 항상 On된다. 만일 서버 요청 부하가 최대가 되면 서버 클러스터에서 얻을 수 있는 가능한 최대 성능을 얻게 되며, 그렇지 않으면 가능한 최대 성능의 일부만을 사용하게 되면서 서버 전력 소비의 효율성은 떨어지게 된다. 부하 상황에 따라 서버의 전력 모드를 제어함으로써 전력 소비의 효율성을 높일 수 있다. 다시 말하면 현재 부하를 처리하는데 필요한 대수의 서버들만 On하고 나머지 서버들은 Off 한다. 기존의 서버 전원 모드 제어 방법에서는 고정된 주기로 서버 전원 모드를 제어하는 정적인 정책을 적용함으로써 동적으로 변하는 부하 환경에 잘 적응하지 못한다. 이를 개선하기 위해 본 논문에서는 동적 서버 전원 제어 알고리즘을 제안한다. 제안 방법에서는 서버 소비 전력의 이력을 갖고서 가까운 장래에 서버 소비 전력이 증가할 것인가를 예측한다. 이 예측에 따라 서버 모드 제어 주기를 동적으로 변경한다. 30대의 PC 클러스터를 이용하여 실험을 수행하였다. 실험을 통하여 일반적인 클러스터링 환경과 비교하여 제안된 방법은 동일한 성능을 유지하면서 29%까지 소비 전력을 절감했다. 또한, 서버 클러스터에서 서버 CPU 사용률 평균은 66% 증가하였다.

Mobile WiMAX시스템에서 채널품질 변동추적을 이용한 유휴모드 이동단말의 효율적인 선호기지국 선택 방안 (Channel Variation Tracking based Effective Preferred BS Selection Scheme of Idle Mode Mobile device for Mobile WiMAX System)

  • 이강규;윤희용
    • 정보처리학회논문지C
    • /
    • 제17C권6호
    • /
    • pp.471-484
    • /
    • 2010
  • 이동통신 시스템에서 이동단말이 소비하는 전력은 휴대용 배터리의 용량 제약으로 인하여 매우 중요하게 고려되는 이슈이다. 따라서, Mobile WiMAX 시스템을 포함한 대부분의 무선통신 네트워크 규격은 이동단말의 전력소모를 줄이기 위한 전력절약 모드를 지원한다. 그러나 이들 규격에서 제시하는 전력절약 모드는 청취구간의 시간적인 배치만을 정의한다. 따라서 전력절약 모드로 동작하는 단말의 소비전력은 단말제조사의 구현형태에 의존적이며, 채널환경 변화에 따라 페이징 손실의 위험성도 존재한다. 본 논문은 광대역 이동통신 네트워크 환경에서 전력절약 모드로 동작하는 이동단말이 채널품질의 변동추이를 바탕으로 최선의 기지국을 선택하는 방식을 통해 보다 효율적인 전력사용 및 청취구간 동안 페이징 메시지의 손실 위험을 줄이는 실용적인 알고리즘을 제시한다. 이러한 채널적응형 주파수/기지국 재선택 알고리즘은 청취구간 동안 채널품질을 측정하는 과정, 측정된 채널품질의 변동을 추적하는 과정, 추적결과에 따라 이종 주파수 탐색을 수행하는 과정, 탐색결과에 따라 최선의 주파수 및 기지국을 재선택 하는 과정으로 구성되어 있다. 그러므로 제안된 방식은 단말이 이동함에 따라 해당 네트워크의 채널환경이 변하더라도 전력을 합리적으로 사용함과 동시에 양호한 기지국을 선택하게 함으로써, 청취구간에서 페이징 메시지 수신성능을 향상시킨다. 본 알고리즘을 적용한 시뮬레이션 결과는 단말의 이동하는 채널환경에서 다른 후보방안들 보다 페이징 메시지 수신성능이 우수함을 보여주고 있으며 동시에 단말이 평균적으로 보다 양호한 채널환경에서 전력절약 모드를 동작하게 함을 보여준다.

셋톱박스의 에너지 효율 개선에 관한 연구 (Study on Improving Energy-Efficiency of Set-top Box)

  • 이상학;윤정미
    • 정보처리학회논문지D
    • /
    • 제18D권3호
    • /
    • pp.197-204
    • /
    • 2011
  • 방송 신호를 수신하여 TV 등의 디스플레이 장치로 전달하는 셋톱박스는 다른 가전과는 다르게 대기모드, 즉 저전력모드가 존재하지 않는다. 이는 기술적 제약과 운용상의 이유로 인한 것이다. 현재 셋톱박스의 전원을 리모컨으로 끄면 방송을 시청하는 온모드 대비 80~90%의 높은 소비전력을 보인다. 이는 1W 미만으로 동작하는 다른 가전에 비해 월등히 높은 것이다. 국내 및 해외 선진국들은 셋톱박스의 에너지 효율을 높이고자 하는 정책을 시행하고 있다. 본 논문에서는 셋톱박스의 에너지 효율을 개선하고자 저전력 셋톱박스를 설계하고 진행 중인 개발에 대해 기술한다. 저전력 모드를 지원하는 SoC, 전원 모드를 구분하여 동작하도록 하는 시스템 하드웨어 및 소프트웨어, 그리고 방송사와의 연동을 통한 전원관리를 이루는 미들웨어 등이 핵심 개발 내용이다. 그리고 이를 통해 이룰 수 있는 에너지 소비 절감 효과를 보인다.

강유전체 세라믹스를 이용한 전자식 안정기용 절전모듈 (Power-saving Module using Ferroelectric Ceramics for Electronic Ballast)

  • 신현용
    • 한국컴퓨터산업학회논문지
    • /
    • 제6권5호
    • /
    • pp.741-748
    • /
    • 2005
  • 형광램프용 전자식 안정기의 효율개선 및 램프의 수명연장을 위하여 강유전체 커패시터와 시간지연스위칭회로로 구성된 절전모듈을 개발하고 적용하였다. 절전모듈에 사용된 강유전체 세라믹스를 이용하여 형광램프의 부저항특성과 최적화를 시키고, 시간지연회로를 통하여 점등초기 예열형에서 비예열형으로 스위칭시켜 점등 중 필라멘트에서 소비되는 전력을 제거함으로써 약 2W의 소비전력을 감소시켜 효율개선을 실현하였으며, 역기전력 제거기능을 통하여 점등 초기 형광램프 필라멘트에 가해지는 충격을 최소화함으로써 형광램프의 수명을 연장시켰다.

  • PDF

A High Frequency-Link Bidirectional DC-DC Converter for Super Capacitor-Based Automotive Auxiliary Electric Power Systems

  • Mishima, Tomokazu;Hiraki, Eiji;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제10권1호
    • /
    • pp.27-33
    • /
    • 2010
  • This paper presents a bidirectional DC-DC converter suitable for low-voltage super capacitor-based electric energy storage systems. The DC-DC converter presented here consists of a full-bridge circuit and a current-fed push-pull circuit with a high frequency (HF) transformer-link. In order to reduce the device-conduction losses due to the large current of the super capacitor as well as unnecessary ringing, synchronous rectification is employed in the super capacitor-charging mode. A wide range of voltage regulation between the battery and the super capacitor can be realized by employing a Phase-Shifting (PS) Pulse Width Modulation (PWM) scheme in the full-bridge circuit for the super capacitor charging mode as well as the overlapping PWM scheme of the gate signals to the active power devices in the push-pull circuit for the super capacitor discharging mode. Essential performance of the bidirectional DC-DC converter is demonstrated with simulation and experiment results, and the practical effectiveness of the DC-DC converter is discussed.

사물 인터넷 환경에서 무선 AP의 수면 모드 운영 및 송출 전력 조절을 통한 전력 소비 절감 알고리즘 (A Wireless AP Power Saving Algorithm by Applying Sleep Mode and Transmission Power Coordination in IoT Environments)

  • 정경채;최원석;최성곤
    • 정보처리학회논문지:컴퓨터 및 통신 시스템
    • /
    • 제3권11호
    • /
    • pp.393-402
    • /
    • 2014
  • 최근 스마트폰을 포함한 사물 인터넷(IoT) 기술 기반의 스마트 기기의 급속한 확산에 따라 IEEE 802.11 무선 랜에서 전력 소비 또한 급격히 증가하고 있다. 특히 모바일 기기 사용자가 급격하게 증가하면서 가정이나 사무실 같은 실내 환경에서 사설 무선 AP(Access Point) 설치가 급증하고 있는 추세이다. 본 논문은 현재 무선 AP의 비효율적인 운영을 개선한 무선 AP의 전력 소비 절감 알고리즘을 제안한다. 제안한 알고리즘 동작은 STA(Station)의 무선 AP 접속 여부에 따라 구분되며, STA가 있을 경우는 STA로 전송할 데이터가 있을 때와 없을 때로 나뉜다. STA가 없는 경우, 수면 모드로 동작하여 불필요한 전력 소비를 최소화한다. 또한 추가적으로 STA가 접속을 하고 있는 경우에도 데이터를 수신하지 않을 경우에는 인증 및 결합이 유지된 상태로 수면 모드를 운영한다. STA로부터 데이터 요청이 있을 경우 STA의 거리와 전송률을 파악하여 STA의 전송률을 만족하는 최소의 송출 전력으로 패킷을 전송한다. 이때, STA와 최초로 스캔 과정을 하는 데 필요한 관리 프레임은 최대 송출 전력으로 전송한다. 본 논문에서 제시한 시나리오를 바탕으로 제안한 전력 소비 절감 알고리즘이 적용된 무선 AP에서의 전력 소비량은 기존 방안이 적용된 무선 AP와 비교하면 약 18%, 전력 소비 절감이 적용되지 않은 일반적인 무선 AP와 비교하면 약 35% 감소했다.

Single Line-to-ground Fault Location and Information Modeling Based on the Interaction between Intelligent Distribution Equipment

  • Wang, Lei;Luo, Wei;Weng, Liangjie;Hu, Yongbo;Li, Bing
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권5호
    • /
    • pp.1807-1813
    • /
    • 2018
  • In this paper, the fault line selection and location problems of single line-to-ground (SLG) fault in distribution network are addressed. Firstly, the adaptive filtering property for empirical mode decomposition is formulated. Then in view of the different characteristics showed by the intrinsic mode functions(IMF) under different fault inception angles obtained by empirical mode decomposition, the sign of peak value about the low-frequency IMF and the capacitance transient energy is chosen as the fault line selection criteria according to the different proportion occupied by the low-frequency components. Finally, the fault location is determined based upon the comparison result with adjacent fault passage indicators' (FPI) waveform on the strength of the interaction between the distribution terminal unit(DTU) and the FPI. Moreover, the logic nodes regarding to fault line selection and location are newly expanded according to IEC61850, which also provides reference to acquaint the DTU or FPI's function and monitoring. The simulation results validate the effectiveness of the proposed fault line selection and location methods.

Independent Metering Valve: A Review of Advances in Hydraulic Machinery

  • Nguyen, Thanh Ha;Do, Tri Cuong;Ahn, Kyoung Kwan
    • 드라이브 ㆍ 컨트롤
    • /
    • 제17권4호
    • /
    • pp.54-71
    • /
    • 2020
  • In light of the environmental challenges, energy-saving strategies are currently under investigation in the construction industry. This paper focuses on the energy-saving method used in the hydraulic system based on independent metering (IM) technologies, which can overcome the lost energy at the main control valve of the conventional electrohydraulic servo system. By scientifically arranging the proportional valves, the IM system can individually control the flow rate of the inlet and the outlet ports of the actuators. In addition, the IMV system can be used to effectively regenerate energy under different operating modes, thereby saving more energy than conventional hydraulic systems. Therefore, the IMV system has a great potential to improve the energy efficiency of hydraulic machinery. The overall IMV system, including the configuration, proportional valve, operation mode, and the control strategy is introduced via state-of-the-art hydraulic technologies. Finally, the challenges of IM systems are discussed to provide researchers with directions for future development.