• Title/Summary/Keyword: Power Saving Control

Search Result 407, Processing Time 0.024 seconds

A Study on Smart Energy Management System using Information and Communication Technology (ICT를 활용한 스마트에너지관리시스템에 관한 연구)

  • Lee, Yong-Soo;Heo, Jun;Choi, Yong-Hoon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.5
    • /
    • pp.167-172
    • /
    • 2014
  • Recently interest in energy is becoming increasingly amplified in the world. Green energy is the buzzword of the world's business community as well as governments also leave a green energy seonbongjang of economic recovery. According to the International Institute for Energy, it will be expected to invest in the field of green energy about 7 trillion dollar traslated into 7,000 trillian won around the world by 2030. Thus production, supply, reduce and reuse policies and techniques for green energy came pouring out like a flood. But there is a limit to the fuel supply in order to produce a power generation facility and the power supply that is essential. Reducing produced power efficiently is more important than the increasing of power production. At present, using a method that controls the equipment installed by measuring the environment for efficient control of the energy management of energy-consuming devices that are in use. But the reality is that many policies of national and corporate to did not work to solve a part of the energy savings. In this paper, I proposes a smart energy management system to control the equipment by using the accumulated data obtained with minimal changes in the environment using the energy.

Evaluation of Heating Performance and Analysis of Heating Loads in Single Span Plastic Greenhouses with an Electrical or Hot-Air Heating (전기히터식 난방, 온풍난방시스템을 채용한 단동 플라스틱 하우스의 열부하 해석 및 난방성능 평가)

  • 허종철;임종환;서효덕;최동호
    • Journal of Bio-Environment Control
    • /
    • v.8 no.2
    • /
    • pp.136-146
    • /
    • 1999
  • A series of experiments were carried out in winter to investigate the indoor thermal environment in greenhouses with different kinds of heating systems, and characterize the energy consumption, heat transport and thermal energy efficiency of each system. By the Quantitative calculation of heat losses which transmit through the covers of greenhouse, the fundamental data of energy-saving of the particular heating system were obtained. And from the analysis of air temperature differences between indoor and outside, it was possible to select more effective energy-saving and comfortable heating system in greenhouses. The electric heater was more stable in thermal environment and cheaper in cost, since it could be used during the surplus time of electric power from 10:00 p.M. to 8:00 A.M. But the low air temperature in greenhouses besides these times resulted in a chilling problem of the crops. The heating system by hot air had the advantage to show nearly uniform temperature difference by the height above the ground. But the system had the disadvantage to require more energy consumption than the electric heating system.

  • PDF

Two Way Set Temperature Control Impact Study on Ground Coupled Heat Pump System Energy Saving (양방향 설정온도 제어에 따른 지중연계 히트펌프 시스템의 에너지 절감량 평가 연구)

  • Kang, Eun-Chul;Lee, Euy-Joon;Min, Kyong-Chon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.10 no.2
    • /
    • pp.7-12
    • /
    • 2014
  • Government has recently restricted heating and cooling set temperatures for the commercial and public buildings due to increasing national energy consumption. The goal of this paper is to visualize a future two way indoor set temperature control impact on building energy consumption by using TRNSYS simulation modeling. The building was modelled based on the twin test cell with the same dimension. Air source ground coupled heat pump performance data has been used for modeling by TRNSYS 17. Daejeon weather data has been used from Korea Solar Energy Society. The heating set temperature in the reference room is $24^{\circ}C$ as well as the target room set temperature are $23^{\circ}C$, $22^{\circ}C$, $21^{\circ}C$ and $20^{\circ}C$. The cooling set temperature of the reference room is also $24^{\circ}C$ as well as the target room set temperature of $25^{\circ}C$, $26^{\circ}C$, $27^{\circ}C$ and $28^{\circ}C$. For the air source heat pump system, heating season energy consumption is $35.52kWh/m^2y$ in the reference room. But the heating energy consumption in the target room is reduced to 7.5% whenever the set temperature decreased every $1^{\circ}C$. The cooling energy consumption in the reference room is $4.57kWh/m^2y$. On the other hand, the energy consumption in the target room is reduced to 22% whenever the set temperature increased every $1^{\circ}C$ by two way controller. For the geothermal heat pump system, heating energy consumption in the reference room is reduced to 20.7%. The target room heating energy consumption is reduced to 32.6% when the set temperature is $22^{\circ}C$. The energy consumption in the target room is reduced to 59.5% when the set temperature is $26^{\circ}C$.

THERMAL-FLUID ANALYSIS FOR COOLING PERFORMANCE IMPROVEMENT OF 3.3KV(105A) COMPACT RACK TYPE MEDIUM VOLTAGE INVERTER SYSTEM (3.3kV(105A) COMPACT RACK TYPE 고압 인버터 시스템의 방열 성능 향상을 위한 열유동 해석)

  • Kim, S.Y.;Kim, S.D.;Ryoo, S.R.;You, N.K.;Kim, T.B.;Hong, C.O.;Ko, H.S.
    • Journal of computational fluids engineering
    • /
    • v.19 no.3
    • /
    • pp.24-28
    • /
    • 2014
  • With ever rising concerns about saving of fossil fuel resource, there have been an increasing demand for use of energy more efficiently. The electric motor driven inverters can be a great help to improve energy efficiency. They are also used to control the motor speed to the actual need. Therefore the use of them can lead to reduce energy consumption. In particular, the medium voltage(MV) drive systems used for pumps, fans, steel rolling mills and tractions have widespread applications in the industry. They cover power ratings from 0.4MW to 40MW at the MV level of 2.3kV to 13.8kV. The majority of the installed MV drive systems however, are in the 1MW to 4MW range with voltage rating from 3.3kV to 6.6kV. But they are required to reduce size and weight like other power electronic equipments. In this paper, we studied on the 3.3kV(105A) compact rack type inverter system for improving the cooling efficiency. At first, we confirmed the tendency of temperature with computational simulation using ANSYS ICEPAK and actual experimental tests. And then we researched thermal performance improvement designs in order to reduce temperature of the transformer for the safe operation. It can reduce temperature of transformer that using pipe type flow guide in the system. As a result, we found out more efficient solution by thermal-fluid analysis.

An Automatic Repeating Protocol in Cooperative Spectrum Sharing (협력적 스펙트럼 공유의 자동 반복 프로토콜)

  • Kong, Hyung-Yun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.6
    • /
    • pp.101-108
    • /
    • 2013
  • In this paper, we propose a method in which the negative acknowledge (NACK) message is used as command for cooperation and spectrum sharing. This allows for an automatic request for cooperation and sharing when the direct link of the primary user is in outage, and also allows for saving the number of control messages in cooperation-spectrum sharing based paradigm. In the sharing phase, the selected relay shares a power fraction of $1-{\alpha}$ for secondary transmitted signal while the remaining of ${\alpha}$ is for primary retransmitted signal. In the case of no relay collected, primary transmitter uses NACK as a command to retransmit the signal with fully power fraction (${\alpha}=1$). Both systems are assumed to employ BPSK signals. In this scheme, we propose the joint optimal decoding in the secondary user. The frame error rate (FER) performance at both systems is then analyzed. The theoretical and simulation results validate the analysis and confirm the efficiency of the protocol.

A Numerical Study on Various Energy and Environmental System (II) (에너지${\cdot}$환경 제반 시스템에 관한 수치해석적 연구(II))

  • Jang D. S.;Park B. S.;Kim B. S.;Lee E. J.;Song W. Y.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1996.05a
    • /
    • pp.58-67
    • /
    • 1996
  • This paper describes some computational results of various energy and environmental systems using Patankar's SIMPLE method. The specific topics handled in this study are jet bubbling reactor for flue gas desulfurization, cyclone-type afterburner for incineration, 200m tall stack for 500 MW electric power generation, double skin and heat storage systems of building energy saving for the utilization of solar heating, finally turbulent combustion systems with liquid droplet or pulverized coal particle. A control-volume based finite-difference method with the power-law scheme is employed for discretization. The pressure-velocity coupling is resolved by the use of the revised version of SIMPLE, that is, SIMPLEC. Reynolds stresses are closed using the standard $k-{\varepsilon}$ and RNG $k-{\varepsilon}$ models. Two-phase turbulent combustion of liquid drop or pulverized coal particle is modeled using locally-homogeneous, gas-phase, eddy breakup model. However simple approximate models are incorporated for the modeling of the second phase slip and retardation of ignition without consideration of any detailed particle behavior. Some important results are presented and discussed in a brief note. Especially, in order to make uniform exit flow for the jet bubbling reactor, a well-designed structure of distributor is needed. Further, the aspect ratio in the double skin system appears to be one of important factors to give rise to the visible change of the induced air flow rate. The computational tool employed in this study, in general, appears as a viable method for the design of various engineering system of interest.

  • PDF

Modeling and Design of an Active Pressure Regulating Valve(Implant) (녹내장 치료용 능동형 압력조절밸브(Implant) 모델링 및 설계)

  • Bae, Byunghoon;Kim, Nakhoon;Lee, Yeon;Kee, Hongseok;Kim, Seoho;Park Kyihwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.5
    • /
    • pp.805-815
    • /
    • 2001
  • Glaucoma is an eye disease which is caused by abnormal high IOP (Intra Ocular Pressure). High IOP is caused by the aqueous humor which is produced consistently but not drained due to malfunction of the trabecular system which has a role of draining the aqueous humor into the venous system. Currently, there are three methods to treat glaucoma-using medicines, surgical operation, and using implant device. The first and second methods are not long acting, so the use of implants is increasing in these days in order to drain out the aqueous humor compulsory. However, though conventional implants have a capability of pressure regulation, they cannot maintain IOPs desired for different patients, and too much aqueous humor are usually drained, to cause hypotony. To solve these problems, it is needed to develop a new implant which is capable of controling the IOP actively and copes with personal difference of patients. An active glaucoma implant consists of the valve actuator, pressure sensor, controller, and power supply. In this paper, firstly, we make an analysis of the operation of a conventional implant using a bond graph and show defects and limitations of the conventional valve analytically. Secondly, we design and analyze a valve actuator considering actuation principles, resistance elements, control methods, and energy sources focused on power saving problem. Finally, using simulations the possibility of the proposed valve actuator is investigated.

Development of Satellite Conceptual Design Software (위성 시스템 개념설계 소프트웨어 개발)

  • Park, Woo-Sung;Yun, Joong-Sup;Ryoo, Chang-Kyung;Choi, Kee-Young;Kim, Hee-Seob
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.9
    • /
    • pp.923-930
    • /
    • 2009
  • In this paper, we introduce a satellite conceptual design software which can be used for outlining a new satellite as well as for educational purpose. This software consists of three commercial tools: MATLAB, STK(Satellite Tool Kit), and Excel. The management of the design software is done by MATLAB which provides basic calculations, GUI(Graphical User Interface), Excel data base management, and STK control. STK, an orbital simulation software developed by AGI, takes a part of obtaining accurate orbital information of a satellite. Excel, a product of Microsoft, is used for the data base of previous satellites and for the saving place of temporary and final results of the software. The conceptual design of a satellite is to roughly estimate power system and mass. In the power system design, the sizes of solar array and battery are determined. Based on the database of existing satellites, we can estimate the subsystems's mass fraction of a target satellite. Design examples for Kompsat 1 and 2 are suggested for verification of the developed software.

A Study on the Tele-controller System of Navigational Aids Using Hybrid Communication (하이브리드 통신을 이용한 항로표지의 원격관리 제어시스템에 관한 연구)

  • Jeon, Joong-Sung;Oh, Jin-Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.842-848
    • /
    • 2011
  • A fabricated hybrid control board using multi-communication is designed with a low power 8-bit microcontroller, ATxmega128A1. The microcontroller consists of 8 UART (Universal asynchronous receiver/transmitter) ports, 2 kbytes EEPROM, 128 kbytes flash memory, 8 kbytes SRAM. The 8 URAT ports are used for a multi-communication modem, a GPS module, etc. The EEPROM is used for saving a configuration for running programs, and the flash memory of 128 kbytes is used for storing a F/W (Firm Ware), and the 8 kbytes SRAM is used for stack and for storing memory of global variables while running programs. If we use the multi-communication of CDMA, TRS and RF to remotely control Aid to Navigation, it is able to remove the communication shadow area. Even though there is a shadow area for an individual communication method, we can select an optimal communication method. The compatibility of data has been enhanced as using of same data frame per communication device. For the test, 8640 of data have been collected from each buoy during 30 days in every 5 minutes and the receiving rate of the data has shown more than 85 %.

Current Status and future of Vermicomposting Industry in Korea (지렁이 퇴비화 운영사례 및 개선방향)

  • Kim, Jong-Oh;Lee, Chang-Ho;Choi, Hun-Gun
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.9 no.4
    • /
    • pp.89-98
    • /
    • 2001
  • Present vermicomposting technology needs the broad land. Because of the high land cost, the land saving technology such as multistage must be needed. And present operation practices are mostly based on human power, mechanization and automation is needed. Also, present control practices based on individual experience need the scientific base control system. Even though the rough estimation of organic waste treatment showed that vermicompostiong could obtain more benefits than costs. But, the estimation is based on an ideal case without considering the technical and market. Generally, vermicomposting is considered as the more expensive technology than composting. Therefore, the practical proof the economic factor would be the most important to the market increase. Vermicomposting as the recycling technology has better condition than incineration and landfill. Propagation and advocating focused on its environmentally sound aspects would be needed continuously. Especially, demonstration and distribution of household vermicomposting would be a good approach. Vermicomposting facilities area was becoming larger, and earthworm feeding materials were also expanding to various organic sludges. These trends showed that vermicomposting is being enlightened to treat and recycle the organic wastes.

  • PDF