• 제목/요약/키워드: Power Quality Cost

검색결과 434건 처리시간 0.024초

통계적 방법을 이용한 전력품질 관리방안 (Applicability of Statistical Evaluation to Power Quality Analysis)

  • 조수환;장길수;권세혁;박상호;전영수;곽노홍
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.22-24
    • /
    • 2006
  • The installations of power quality monitoring system have increased drastically over the past several decades. These systems have been effectively used to monitor, analyze and diagnose the conditions of power system, and furthermore can be used to improve the present asset maintenance policy, scheduled (time-based) method, into the advanced, cost-effective and labor-effective maintenance methods, such as condition-based maintenance, predictive maintenance and reliability centered maintenance. As an approach to this, this paper introduces the statistical methods, three kinds of control charts (Shewhart chart, CUSUM chart and EWMA chart), and discusses the applicability of these methods to recognize the changing trends of power quality indices and to estimate the system's condition, using Matlab.

  • PDF

UPS를 고려한 계통연계 전류제어형 전압원 인버터 (Gird-interactive Current Controlled Voltage Source Inverter System with UPS)

  • 고성훈;임성훈;이수원;이성룡
    • 전기학회논문지
    • /
    • 제56권6호
    • /
    • pp.1064-1070
    • /
    • 2007
  • This paper presents a grid-interactive current controlled voltage source inverter (CCVSI) with uniterruptible power supply (UPS), which uses an inner current control loop (polarized ramp time (PRT)) and outer feedback control loops to improve grid power quality and UPS. To reduce the complexity, cost and number of power conversions, which results in higher efficiency, a single stage CCVSI is used. The operation of this system could be divided into the power quality control (PQC) state mode and the UPS state mode. In PQC mode, the system operated to compensate the reactive power demand by nonlinear load or variation in load. In UPS mode. the system is controlled to provide a sinusoidal voltage at the rated value for the load when the gird fail. To verify the proposed system, a comprehensive evaluation with theoretical analysis, simulation and experimental results for 1KVA load capacity is presented.

미국 전력시장에서의 전력품질의 차별화 전략 검토 (Review for Differentiated Strategy of Power Quality in the U.S.A)

  • 최상봉;김대경;정성환;김호용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.207-209
    • /
    • 2001
  • Intensive competition in the electricity market and demand for higher quality service force the utilities to change their strategies in setting price and quality combination. As cost-up by homogeneously enhancing the electricity service quality may reduce their competitiveness, differential service is to be taken into consideration. Priority Service, which provides customers with a selection of service options at a range of prices and reliability for all or portions of their loads, has drawn attention from utilities in an increasingly competitive environment. Priority Service is to enlarge service options for customers who have diverse needs for supply reliability. This paper in the light of this point reviews differentiated strategy of power quality in the U.S.A.

  • PDF

전력설비 동작 상태 감시를 위한 저가형 전력 성분 측정 및 기록 시스템의 개발 (The Development of Low Cost Power Components Measurement and Record System for Monitoring Electrical Equipment Operation Status)

  • 전정채;오훈
    • 한국산학기술학회논문지
    • /
    • 제16권7호
    • /
    • pp.4855-4862
    • /
    • 2015
  • 본 논문에서는 전력설비의 동작 상태를 주기적으로 감시 및 기록함으로써 전기안전사고를 예방하고 사후 원인 분석을 지원하기 위한 저가형 전력 성분 측정 및 기록 시스템을 제안한다. 제안된 시스템에서는 정밀한 전력 성분의 측정과 기록, 원격 측정이 가능하면서도 비용을 줄일 수 있도록 부품을 선정하여 제작하였다. 특히, IEEE 1459-2010에 정의된 전력 성분을 계산하기 위해 MAXIM사의 78M6631을 이용함으로써 저비용 고성능 시스템 구현이 가능하였다. 개발된 시스템은 공인 시험기관에서 사용하고 있는 YOKOGAWA 전력분석기 WT1600 과 같은 표준 장비를 이용하여 측정 성능 시험을 실시하였다. 그 결과 측정 오차가 0.5%이하로 나타났고 6개월 이상 현장에 설치하여 동작 신뢰성과 원격 측정 성능 시험을 실시하여 그 성능을 입증하였다.

국내 배편계통의 최적 개폐기 설치 기준 (The Optimized Standards and Criteria for Installing Switches on Distribution Feeder)

  • 조남훈;하복남;이흥호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제51권5호
    • /
    • pp.238-246
    • /
    • 2002
  • Utilities are trying to install the equipment of high quality to avoid deterioration of supply reliability. In addition, many sectionalizing switches which can decrease the total outage value for a fault are installed for the same reason. Therefore, utilities are interested in stun dards and criteria for installing switches to optimize the total cost on distribution systems. The affect of sectionalizing switches installed on distribution feeder is gradually decreased because the failure rate on distribution feeder is decreased. Also the automation for distribution systems is widely applied for the efficient operation. Therefore, the renewal for installation standards of sectionalizing switches Is required to reflect the current operation situation. The variable data is used to consider the KEPCO's real situation of distribution feeder as follows; the feeder capacity, connecting rate, feeder length, failure rate of distribution feeder, the failure rate of switches, perception time of feeder fault, the restoration time for a faulted section, the transfer time to other feeders, and the switching time. In this study, We propose equations which can determine the number of sectionalizing switches for minimizing the outage and switch installation cost.

3상 PWM Converter를 위한 정지 좌표계법 Analog 제어기 설계 및 시뮬레이션 (Design and Simulation of analog controller for 3 Phase PWM Converter Based on Stationary Reference Frame)

  • 이영국;노철원;최종률
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1997년도 전력전자학술대회 논문집
    • /
    • pp.14-20
    • /
    • 1997
  • Due to several advantages of Pulse Width Modulated(PWM) Converter, such as unity power factor with low-harmonics and energy regeneration, PWM converter has been widely used in industrial application. In every application of energy conversion equipment, the design and implementation must be carried out considering performance and cost. High quality with low cost is the best choice for energy conversion equipment. High dc link voltage can reduce inverter and motor side losses and system dimension compare to low dc link voltage. Analog controller can make PWM converter cheaper without considerable degradation of the performance than digital controller. This paper shows the simplified analog controller-for 600V dc link voltage using stationary reference frame control and the simulation results.

  • PDF

A Data-line Sharing Method for Lower Cost and Lower Power in TFT-LCDs

  • Park, Haeng-Won;Moon, Seung-Hwan;Kang, Nam-Soo;Lee, Sung-Yung;Park, Jin-Hyuk;Kim, Sang-Soo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.531-534
    • /
    • 2005
  • This paper presents a new data line sharing technique for TFT-LCD panels. This technique reduces the number of data driver IC's to half by having two adjacent pixels share the same data line. This in turn doubles the number of gate lines, which are integrated directly on the glass substrate of amorphous silicon for further cost reduction and more compactness. The proposed technique with new pixel array structure was applied to 15.4 inch WXGA TFT-LCD panels and has proven that the number of driver IC's were halved with nearly 41% circuit cost reduction and 5.3% reduction in power consumption without degrading the image quality.

  • PDF

Study on mold sterilization using High Electric field generation system

  • Kee-Yeon Joe
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.535-538
    • /
    • 2000
  • There are several electricity applied sterilizers such as sterilizer with high frequency sterilizer with ozone sterilizer with high voltage and so on Those sterilizers feature "because there is no chemical process there is no secondly environmental pollution" At the power conversion part ZVS and ZCS methods have been used that it results in reduced switching loss miniaturized size and lightened weight, Besides the current in the device is smaller than that of existing method. Thus it is expected that the cost of sterilization process when quality of the device is measured by power consumption will be reduced.e reduced.

  • PDF

살균처리 장치용 전력변환장치 (Power Converter System for Sterilization processing Device)

  • 강욱중;고강훈;서기영;이현우
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(5)
    • /
    • pp.237-240
    • /
    • 2001
  • There are several electricity applied sterilizers such as sterilizer with high frequency, sterilizer with ozone, sterilizer with high voltage, and so on. Those sterilizers feature “because there is no chemical process, there is no secondly environmental pollution” At the power conversion part, AVS and ZCS methods have been used that it results in reduced switching loss, miniaturized size, and lightened weight. Besides, the current in the device is smaller than that of existing method. Thus, it is expected that the cost of sterilization process, when quality of the device is measured by power consumption, will be reduced.

  • PDF

태양광 멀티레벨 단상 인버터를 위한 단일 스위치를 가지는 삼중 출력 DC/DC 컨버터 설계 및 해석 (Design and Analysis of a Triple Output DC/DC Converter with One Switch for Photovoltaic Multilevel Single Phase Inverter)

  • 최우석;박성준
    • 조명전기설비학회논문지
    • /
    • 제28권8호
    • /
    • pp.82-89
    • /
    • 2014
  • The industrial products to use single phase inverter are raised the necessity of power quality improvement, such as AC Motor Driver, Lighting, Renewable energy power converter. Also, it is increasing that applied the single phase multilevel inverter for high quality power at renewable energy power converter. Especially, the photovoltaic multilevel inverters have at least more than two DC_Link and more than one DC/DC Converter. This paper proposes a triple output DC/DC Converter with one switch for photovoltaic multilevel inverter. The proposed converter has advantages of low cost and volume because it has one switch. The operation principle of the converter is analyzed and verified. A prototype is implemented to verify of the proposed converter.