• Title/Summary/Keyword: Power Quality Cost

Search Result 434, Processing Time 0.027 seconds

Harmonic and Interhamonic Detection and Estimation of Power Signal using Subband MUSIC/ESPRIT (부밴드 MUSIC/ESPRIT를 이용한 전력신호 고조파 및 중간고조파 검출 및 추정)

  • Choi, Hun;Bae, Hyeon-Deok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.1
    • /
    • pp.149-158
    • /
    • 2015
  • This paper proposes a subband filtering technique to the MUSIC and the ESPRIT algorithm for estimating the magnitude and frequency of the harmonics of power signal. In proposed method, the input power signal is decomposed to the odd harmonics and the even harmonics respectively by the filter bank system. The amplitude and the frequency estimation of the decomposed harmonics are carried out using the MUSIC and the ESPRIT method. Subband filtering can reduce the autocorrelation matrix size of input data, and spectrum leakage between adjacent harmonics. Therefore, this subband technique has advantage in computational cost and estimation accuracy compared to fullband MUSIC and ESPRIT. To demonstrate the performance of the method, computer simulations are performed to the synthesized input signal, and experiment results are compared in subband and fullband cases.

Power plant instrumentation and control system by using optical fiber cable (광케이블을 이용한 발전소 계측제어시스템)

  • 신건학;조홍근;오면택
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.79-84
    • /
    • 1990
  • Analog systems could not fully deal with instrumentation and control facilities in power plants since these facilities have become more and more complex on account of various needs for large power generation capacity highly cost effective operation to conserve energy and operation management to prevent pollution. Digitalizations of control device and augmentations of control informations increased the necessity of fiber optic data networks which have excellent noise immunity and high quality wide-band with information transfer capability. The goal of this study is to offer a fiber optic data-way system which has high reliabilities, high data transmission rates and small cable ducts with large transmission capacities for the instrumentation and control of power plants.

  • PDF

Development of Prefabricated Joint for 66kV Cross Linked Polyethylene Cable. (66kV XLPE Cable용 조립형 접속함의 개발)

  • Oh, E.J.;Kim, K.Y.;Lee, J.Y.;Park, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2123-2125
    • /
    • 1999
  • In recent the XLPE cable has been applied more widely because of its advantages, such as the low-cost and simple installation. For a prefabricated joint, its working time is short, its jointing procedures aγe simple, and its quality control is easy. Electrical performance targets of our developed 66kV cable accessories has been approved through the type test in accordance with IEC publication 840. This paper describes the developmental effort in terms of the design, structure and results of performance verification tests for 66kV XLPE cable system.

  • PDF

765kV Transmission maintenance live-line work study (765kV 송전선로 유지.보수 활선공법 고찰)

  • Choi, Han-Yeol;Min, Byeong-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.723-724
    • /
    • 2007
  • Live line work is well known for mending and maintenance of electrical power equipment. Nowadays needs of electric power supply quality require live line work In Korea, live line work is needed since 765kV transmission operation and restructure of electric power industry has changed. In other words, in case of suspension of power supply on the transmission is getting hard to keep up with efficiency of transmission operation, customer's confidence and generation-limited cost. Therefore live line work is very meaningful. As the condition of 765kV Transmission both bare hand and Helicopter live line technique must be used in moderation because of economic, geographical, environmental circumstances around steel tower.

  • PDF

The Development of Real-Time Harmonic Analysis Algorithm in Distribution Transformer (배전용 변압기의 실시간 고조파 분석 알고리즘 개발)

  • Park, Chul-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.3
    • /
    • pp.43-49
    • /
    • 2013
  • Recently harmonics flowing into power system is increasing as the usage of semiconductor equipments and switching mode power equipments are increasing. Harmonics cause problems such as heat increasing and reduction in capacity of transformers, especially the harmonics flowing into a distribution transformer can lead to the lifetime reduction of transformer. In this paper, we are about to develop a device that can monitor harmonics in real-time as it is affixed to a distribution transformer. Unlike the existing expensive harmonic analysis device, a new harmonic analysis algorithm is proposed in order to implement low-cost equipment. The real-time harmonic analysis algorithm proposed in this paper allows implementation on low performance microcontrollers, thus it can monitor the harmonic in real-time as it is individually affixed to the transformer. Therefore, it would improve the reliability of the transformer and stable power system operation would be possible as it can prevent the transformer accidents in advance.

Simulation of High-Frequency Induction-Heating Application Power Supply at 2700kW Power (2700kW급 고주파 유도가열장치의 전원시스템 시뮬레이션)

  • Lee, K.S.;Koh, H.S.;Lee, Y.H.;Lee, H.W.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.189-191
    • /
    • 1998
  • The development of the high- frequency induction-heating for 2700kW power range intend to make localization at forging and rolling mill part by technical innovation. And, the development makes to increase our's competitive power at technique, quality and cost. This paper describes the heart of high-frequency induction-heating technique, switching technique, a few problem in common using as an unsatisfied technique, load adjustment technique, system control, diagnostic system and auto-interface etc.

  • PDF

A PC-Based System for Gear Pitch Analysis and Monitoring in Gear Manufacturing Process (기어피치분석 및 공정관측을 위한 PC기반시스템 구축)

  • 김성준;지용수
    • Journal of Korean Society for Quality Management
    • /
    • v.30 no.3
    • /
    • pp.111-119
    • /
    • 2002
  • Gears are essential elements for mechanical power transmission. Geometric precision is the main factor for characterizing gear grade and qualify. Gear pitch is one of the crucial measurements, which is defined as a distance between two adjacent gear teeth. It is well-known that variability in gear pitches may causes wear-out and vibration noise. Therefore maintaining pitch errors at a low level plays a key role in assuring the gear quality to customers. This paper is concerned with a case study, which presents a computerized system for Inspecting pitch errors in a gear machining process. This system consists of a PC and window-based programs. Although the start and stop is manually accomplished, the process of measuring and analyzing pitch data is automatically conducted in this system. Our purpose lies in reducing inspection cost and time as well as Increasing test reliability. Its operation is briefly illustrated by example. Sometimes a strong autocorrelation is observed from pitch data. We also discuss a process monitoring scheme taking account of autocorrelations.

Development of the Numerical Guide for Cost-Benefit Analysis of Occupational Radiation Exposure In the Korean Next Generation Reactor

  • Sohn, Ki-Yoon;Kang, Chang-Sun
    • Nuclear Engineering and Technology
    • /
    • v.29 no.1
    • /
    • pp.78-84
    • /
    • 1997
  • The specific purpose of this study is to develop the numerical guide for the cost-benefit analysis of ORE ($/person-Sv reduction) to meet the criterion of ALARA in the design stage of the KNGR. In deriving the guide, the risk factor which is defined by the risk to unit collective radiation exposure dose (deaths/person-Sv) and the monetary value of human life ($/death) are required. The risk factor has been estimated from various clinical data accumulated for a number of years and continuously modified. And the monetary value of human life is usually quantified using the human capital approach. In this study, the risk to radiation exposure perceived by a group of people is investigated through an extensive poll survey conducted among university students in order to modify the existing risk factor for radiation exposure. And in evaluating the monetary value of human life, the QOL factor is introduced in order to incorporate the degree of public welfare or quality of life. As a result of study, a value within the range of 151, 000~172, 000 dollars per person-Sv reduction is recommended as the appropriate interim numerical guide for cost-benefit analysis of ORE to meet the criterion of ALARA in the design stage of the KNGR. A poll survey was also conducted in order to see whether the public acceptance cost of nuclear power should be incorporated in developing the guide, and the result of study shooed that such a cost does not need to be considered.

  • PDF

Probabilistic Method of Risk Assessment in Voltage Sag Mitigation Studies (순간전압강하 보상을 위한 확률론적 위험도 분석 연구)

  • Han, Jong-Hoon;Jang, Gil-Soo;Park, Chang-Hyun
    • Journal of IKEEE
    • /
    • v.14 no.3
    • /
    • pp.236-243
    • /
    • 2010
  • Power quality mitigation devices play an important role in lots of industrial segments. Although there were many devices available in the market, the selection of an appropriate device specially for voltage sags and interruptions mitigation has been a challenge in the utility and customer for several years. It usually depends on technical and economic characteristics of the device. Nevertheless, most mitigation method is selected by rule of thumb or empirical method. In this paper, the life cycle cost analysis for the probabilistic risk assesment of voltage sag mitigation method is performed using either the deterministic or probabilistic approach. The difference between a deterministic and a probabilistic cost analysis approach is illustrated with five different case studies. This paper not only provides a comparison of life cycle costing of various devices but it also indirectly shows the possible savings due to the mitigation of voltage sags in the form of a project balance chart.

Prediction model for electric power consumption of seawater desalination based on machine learning by seawater quality change in future (장래 해수수질 변화에 따른 머신러닝 기반 해수담수 전력비 예측 모형 개발)

  • Shim, Kyudae;Ko, Young-Hee
    • Journal of Korea Water Resources Association
    • /
    • v.54 no.spc1
    • /
    • pp.1023-1035
    • /
    • 2021
  • The electricity cost of a desalination facility was also predicted and reviewed, which allowed the proposed model to be incorporated into the future design of such facilities. Input data from 2003 to 2014 of the Korea Hydrographic and Oceanographic Agency (KHOA) were used, and the structure of the model was determined using the trial and error method to analyze as well as hyperparameters such as salinity and seawater temperature. The future seawater quality was estimated by optimizing the prediction model based on machine learning. Results indicated that the seawater temperature would be similar to the existing pattern, and salinity showed a gradual decrease in the maximum value from the past measurement data. Therefore, it was reviewed that the electricity cost for seawater desalination decreased by approximately 0.80% and a process configuration was determined to be necessary. This study aimed at establishing a machine-learning-based prediction model to predict future water quality changes, reviewed the impact on the scale of seawater desalination facilities, and suggested alternatives.