• 제목/요약/키워드: Power Quality Characteristics

검색결과 1,193건 처리시간 0.032초

주파수 조정을 위한 4MW 전력 저장 시스템 연구 (The Study on 4MW Energy Storage System for Frequency Regulation)

  • 고광수;이충우;강병관;오승훈;이윤재;최은식;류강열;김희중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 추계학술대회 논문집
    • /
    • pp.125-126
    • /
    • 2013
  • ESS(Energy Storage System) for Improve the quality of the power grid, supply reliability, system stability and the efficient operation method of power is drawing attention. According to changes in the load of the power system frequency will be adjustable in real time in response to changes in the frequency of the grid, so thermal power output is mainly controlled in order to keep the grid frequency stable. ESS for adjusting the frequency of the grid when the frequency rises to grid and charge the energy storage device. If the frequency drops to discharge the battery power to the grid and the future is expected to replace the thermal power plant. This paper describes 4MW ESS for the frequency regulation and find out about the characteristics through the PSCAD/EMTDC.

  • PDF

전력시장에서의 적정 운영예비력 기준에 관한 연구 (A Study on Operation Standards for Optimal Operating Reserve in Electricity Market)

  • 류성호;이강완;김광원;황갑주
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권5호
    • /
    • pp.287-293
    • /
    • 2003
  • The deregulation and structural reform of power markets have started from the early 90s, which has brought about new studies on the new environment. Regardless the market structure, however, power systems need to be operated and planned in a stable and reliable manner. Therefore, decisions on proper amount of operating reserves and their reliable operations are very important. Up to now, the decision processes of operating reserves depend mainly on experiences of operators in Korea. When Korean power market comes under private management, operating reserves would influence power rate as well as power Quality, Therefore, it is time to prepare reasonable operating reserve standards in a systematic way for the new environment. This study suggests the proper operating reserve standards considering rules of the power market in Korea. To verify the adequacy of the proposed standards, stability and frequency characteristics of the Korean power system are analyzed as well.

전력시스템 고조파 모델링에 관한 연구 (Harmonic Modeling for Power Systems)

  • 왕용필;정형환;한형주;곽노홍;전영수;박상호;김경철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.147-148
    • /
    • 2006
  • Recently, due to increasing the application of power electronic equipment, harmonics generated from the non-liner load are fairly produced. Harmonics can cause a variety of problems such as the overheating of distribution transformer, the breakdown of device and communication interference. Interest about power quality decline of power system is very increased. In this paper, we are measured the harmonic voltage and current o( power system to analyze harmonic characteristics, and it is analyzed Total Harmonic Distortion(THD). Also, we Ere modeled power system using PSCAD/EMTDC. And it is analyzed harmonic voltage and current in steady-state. The study results have been indicated the utility about harmonics analysis and modelling for power system.

  • PDF

Electrical Technologies for Grid Integration of Ocean Wave Power into the UK National Grid

  • Ahmed, Tarek
    • Journal of Power Electronics
    • /
    • 제10권3호
    • /
    • pp.320-327
    • /
    • 2010
  • In this paper, multiple offshore wave energy converters with different output characteristics are connected to one power distribution substation. The connection between the power take-off of the different wave energy converters and the electrical power transmission system is presented in order to investigate whether multiple wave energy converters can augment energy yield and improve network integration capabilities. Moreover, the model of an array of wave energy converters is developed with the goal of analyzing the effects of the offshore wave farm on the electrical network to which it is connected. It is also developed to ensure that the electricity generated by the array is sufficiently controllable, and of a quality that can be integrate into the electricity supply network without unduly increasing the cost of connection, production or delivery.

비선형 부하의 증감에 따른 고조파 특성 분석 (Analysis on the Harmonics Characteristics due to increase & decrease of Nonlinear load)

  • 김종겸;이운웅;김일중;김성헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.87-91
    • /
    • 2003
  • Most of the loads in industrial power distribution systems are balanced and connected to three wires power systems. However, in the user power distribution systems, most of the loads are single & three phase and unbalanced, generating a large amount of non-characteristic harmonics. With the advent of power electronics and proliferation of non-linear loads in industrial power applications, power harmonics and their effects on power quality are a topic of concern. Harmonics by the unbalance voltage and non-linear loads, cause the increase of machine loss and heating. In order to allow current harmonic compensation, a filter must be installed. This paper describes the performance of passive filter under the voltage unbalance and non-linear load.

  • PDF

불평형 전압으로 운전하는 비선형 부하의 고조파 특성 분석 (Analysis on the Harmonic Characteristics of Nonlinear Load Operated by Unbalance Voltage)

  • 김종겸;이은웅;이동주
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권10호
    • /
    • pp.491-500
    • /
    • 2003
  • Most of the loads in industrial power distribution systems are balanced and connected to three wires power systems. However, in the user power distribution systems, most of the loads are single & three phase and unbalanced, generating a large amount of non-characteristic harmonics. With the advent of power electronics and proliferation of non-linear loads in industrial power applications, power harmonics and their effects on power quality are a topic of concern. Harmonics by the unbalance voltage and non-linear loads, cause the increase of machine loss and heating. In order to allow current harmonic compensation, a filter must be installed. This paper describes the performance of passive filter under the voltage unbalance and non-linear load.

부하특성실험을 위한 전원공급장치 개발 (Development of Power Supply Device for Load Characteristic Experimentation)

  • 이종필;지평식;임재윤
    • 전기학회논문지P
    • /
    • 제54권2호
    • /
    • pp.101-107
    • /
    • 2005
  • The reduced power quality due to some of disturbances on power system has great influence on the efficient and life of load for bad with serious economic loss. The response of load about disturbance needs to analysis quantitatively in detail to improve load characteristics. In this research, a power supply device is developed to supply disturbed power similar to that of power system. The developed device can output a voltage and frequency from 180[V] to 240[V], 55[Hz] to 65[Hz] respectively. The most outstanding feature of this device is a function to be performed steady and dynamic state characteristic experiment on load or appliances. Also, this device is designed to include high accuracy ouput and simple measurement.

불평형 전압 공급시 비선형 부하의 고조파 특성 해석 (Analysis on the Harmonic Characteristics of Nonlinear Load operated by Unbalance Voltage)

  • 김종겸;이은웅;이동주;이화수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.696-698
    • /
    • 2003
  • Most of the loads in industrial power distribution systems are balanced and connected to three wires power systems. However, in the user power distribution systems, most of the loads are single & three phase and unbalanced, generating a large amount of non-characteristic harmonics. With the advent of power electronics and proliferation of non-linear loads in industrial power applications, power harmonics and their effects on power quality are a topic of concern. Harmonics by the unbalance voltage and non-linear loads, cause the increase of machine loss and heating. In order to allow current harmonic compensation, a filter must be installed. This paper describes the performance of passive filter under the voltage unbalance and non-linear load.

  • PDF

고속열차 전기적 이선 특성 측정 방안 연구 (A Study of the Current Collection Characteristics Measurement Methodology for a High-Speed Train)

  • 조홍식;한인수;이태형;김석원;김영국
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.3052-3058
    • /
    • 2011
  • A high-speed train is the system that the electric power is supplied through the overhead contact line and drives motors. In this case that the de-wiring beteen the overhead contact line and the pantograph of a high-speed train, the occasion that smooth power supply is not accomplished occurs sometimes. If the de-wiring occurs, the arc discharge may damage the overhead contact line or the pantograph, and the falling-off in power quality may cause the damage and malfunctioning of motor block. This paper presents the methodology that the arc discharge by de-wring between overhead line and pantograph is discriminated through measuring the PT and CT in the vehicle, and measures the current collection characteristics for a high speed train.

  • PDF

수차발전기 축계의 진동해석 (Vibration Analysis of Hydraulic Turbine-Generator Rotor)

  • 김용한;손병구;최병근;양보석;하현천
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1998년도 춘계학술대회논문집; 용평리조트 타워콘도, 21-22 May 1998
    • /
    • pp.250-254
    • /
    • 1998
  • Pump-storage power plants, which pumps water from the lower reservoir to the upper reservoir using the extra electronic power at night and generates the electronic power in the daytime, are more increasing. Currently it has a tendency to be high-head large-capacity machines. So in the processing of design, we need to know the vibration characteristics of pump-turbine shaft system sufficiently. In this paper, we developed the computer programs for analyzing pump-turbine shaft system considering magnetic force of generator, hydraulic force at runner, dynamic characteristics of guide bearings and the effect of add mass of water. And the superiority of this program was verified by applying it to the real model and calculating high quality critical speed, natural mode and unbalance response.

  • PDF