• 제목/요약/키워드: Power Plant Monitoring

검색결과 481건 처리시간 0.024초

혼소율을 고려한 화력 발전소의 CO2 대기배출량 계산 (Calculation of CO2 Emission for Fossil-Fired Thermal Power Plant considering Coal-Oil Mix Rate)

  • 이상중;김순기
    • 조명전기설비학회논문지
    • /
    • 제24권10호
    • /
    • pp.67-72
    • /
    • 2010
  • G8 summit meeting held in July 2008 decided to set up a long-term goal, by 2050, reducing the world greenhouse emissions by half of those emitted in 1990. In November 2009, the Government announced to reduce the national $CO_2$ emission by 30[%] of BAU by 2020. Electric power industries in Korea produce most of their electricity by burning fossil fuels, and emit approximately 28[%] of national $CO_2$ emissions. Monitoring the $CO_2$ emissions. Monitoring the $CO_2$ emission of electric power plants is very important. This paper presents a method to calculate the hourly $CO_2$ emission for a thermal power plant burning mixture of coal and oil using the performance test data and coal-oil mix rate. An example of $CO_2$ emission calculation is also demonstrated.

중수로 원전 주변 환경 및 인체 삼중수소 방사능 모니터링에 관한 고찰 (A Study on the Environment and Human Tritium Radiation Monitoring around the Heavy Water Nuclear Power Plant)

  • 한상준;이홍연;김보길;하혜경;신용주
    • 방사선산업학회지
    • /
    • 제17권4호
    • /
    • pp.427-436
    • /
    • 2023
  • As a result of evaluating the level of tritium emitted from the nuclear power plant in the environment and the human body, it was confirmed that tritium was detected in the environmental media and human urine samples to be investigated. It was found that the tritium was clearly detected. After the operation of the Tritium Removal Facility (TRF), which was operated for the purpose of removing tritium from the Wolsong nuclear power plant, the tritium emission showed a decreasing trend, and the tritium level in the environmental media also showed a tendency to decrease accordingly. However, for precise evaluation, it was necessary to select and investigate points by distance, season, and wind direction from the nuclear power plant, but it also showed characteristics that did not reflect this. As the cycle, etc., implemented the previous environmental monitoring program as it is, there was also a limitations in not being able to reflect the changing environment. Therefore, it is necessary to review and supplement the environmental monitoring investigation plan and results so far, and by applying the supplemented investigation plan to secure valid and reliable investigation results, it is judged that it will be an appropriate measure for environmental conservation and human protection in the vicinity of the nuclear power plant.

Proposed Neural Network Approach for Monitoring Plant Status in Korean Next Generation Reactors

  • Varde, P.V.;Hur, Seop;Lee, D.Y.;Moon, B.S.;Han, J.B.
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • 제3권1호
    • /
    • pp.112-120
    • /
    • 2003
  • This paper reports the development work carried out in respect of a proposed application of Neural Network approach for the Korean Next generation Reactor (KNGR) now referred as APR-1400. The emphasis is on establishing the methodology and the approach to be adopted towards realizing this application in the next generation reactors. Keeping in view the advantages and limitation of Artificial Neural Network Approach, the role of ANN has been limited to plant status or to be more precise plant transient monitoring. The simulation work carried out so far and the results obtained shows that artificial neural network approach caters to the requirements of plant status monitoring and qualifies to be incorporated as a part of proposed operator support systems of the referenced nuclear power plant.

발전량 예측 모델 기반의 태양광 모니터링 시스템 고장 예측 (Fault Prediction of Photovoltaic Monitoring System based on Power Generation Prediction Model)

  • 홍제성;박지훈;김영철
    • Journal of Platform Technology
    • /
    • 제6권2호
    • /
    • pp.19-25
    • /
    • 2018
  • 기존의 태양광 발전 모니터링 시스템은 현재의 발전량, 과거의 발전량, 환경센서 값등을 모니터링 한다. 이는 발전소의 효율적인 운영과 유지보수를 위한 태양광 발전량 예측이 필요하기 때문이다. 이를 위해 데이터 축적을 통해 빅데이터 기반 태양광 발전 모니터링 시스템의 발전량 예측 알고리즘 구현 방안을 제안한다. 이를 통해 미리 예측된 발전량에 비례하여, 태양광 발전 플랜트의 고장을 예측하고자 한다. 결과적으로 시스템의 고장을 예측하여 미리 점검하도록 한다.

발전소용 무정전전원장치 (UPS)개발 (The Development of Uninterruptible Power Supply for Power Pla)

  • 김동욱;김연풍;신현주;백병산;류승표;민병권
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 F
    • /
    • pp.2085-2087
    • /
    • 1997
  • The UPS for power plant is mainly used as the critical power supply of power plant. This is very much alike to the general UPS but it requires the special design criteria of power plant. In this study, we designed and develope system according to the design criteria of p plant. In the development of the special system, the designs of IGBT Drive, heat protection and monitoring system, and p components are key techniques. This Paper describes the power circuits, key techniques, the control and monitoring of the developed UPS(DC 125V $3{\Phi}$ 100K Finally, using the UPS we verified superiority through the type test.

  • PDF

디지털보호계전기를 이용한 기중차단기 제어 및 모니터링 (Control And Monitoring Of Air Circuit Breaker Using Digital Protective Relay)

  • 이성환;박상배;안인석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.240-242
    • /
    • 2001
  • On this research, to catch up with international trend on the power system utilities move to be digitalized and move to network is certainly technological on the global business world, to compete with advanced foreign countries in the range of transmit and distribute power system and to take possession of first market share within country, we talked over a monitoring system to diagnose, monitor ACB(Air Circuit Breaker) only which is operated on the low level voltage Power plant. AMS(ACB Monitoring System) have be configured with several modules such as engine module which acquire engineering data from HICM360/860(Communication Control Units) and analyze and save it, database module which restore data and can be inquired, system monitoring view module which reflects fields information within a second, realtime trend window, historical trend window, reports as daily and yearly. In a near future, AMS must upgrade GUI to have easy to handle and have to have a field test to fit on real plants, so it will have faith in system reliability as it can apply power plant monitoring system in wide.

  • PDF

FPGA integrated IEEE 802.15.4 ZigBee wireless sensor nodes performance for industrial plant monitoring and automation

  • Ompal, Ompal;Mishra, Vishnu Mohan;Kumar, Adesh
    • Nuclear Engineering and Technology
    • /
    • 제54권7호
    • /
    • pp.2444-2452
    • /
    • 2022
  • The field-programmable gate array (FPGA) is gaining popularity in industrial automation such as nuclear power plant instrumentation and control (I&C) systems due to the benefits of having non-existence of operating system, minimum software errors, and minimum common reason failures. Separate functions can be processed individually and in parallel on the same integrated circuit using FPGAs in comparison to the conventional microprocessor-based systems used in any plant operations. The use of FPGAs offers the potential to minimize complexity and the accompanying difficulty of securing regulatory approval, as well as provide superior protection against obsolescence. Wireless sensor networks (WSNs) are a new technology for acquiring and processing plant data wirelessly in which sensor nodes are configured for real-time signal processing, data acquisition, and monitoring. ZigBee (IEEE 802.15.4) is an open worldwide standard for minimum power, low-cost machine-to-machine (M2M), and internet of things (IoT) enabled wireless network communication. It is always a challenge to follow the specific topology when different Zigbee nodes are placed in a large network such as a plant. The research article focuses on the hardware chip design of different topological structures supported by ZigBee that can be used for monitoring and controlling the different operations of the plant and evaluates the performance in Vitex-5 FPGA hardware. The research work presents a strategy for configuring FPGA with ZigBee sensor nodes when communicating in a large area such as an industrial plant for real-time monitoring.

수력발전소 정비변수 및 회전체 통합관리 시스템 개발 (Development of an Integrated Management System for Maintenance Parameters and Rotary Machine of Hydro-power Plant)

  • 신성환;박진호;윤두병
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2012년도 춘계학술대회 논문집
    • /
    • pp.263-269
    • /
    • 2012
  • Condition-based maintenance (CBM) has been used as a useful concept for optimizing maintenance plan and decreasing maintenance cost in several kinds of plant sites. This study introduced an example that developed an integrated management system for maintenance parameters and hydraulic turbine of hydro-power plant in order to improve its maintenance system as applying CBM techinique. The integrated management system consists of three parts. One is a hardware part including PDA inspection system and several kind of precision measuring instruments. Another is a vibration monitoring system on hydraulic turbine. The other is a software part that takes charge of making hierarchy tree of maintenance parameters and their inspection route, managing accumulated database, assessing health condition of components, and supporting interface with other enterprise management system. The system has been installed at Chuncheon Hydro-power plant for test and demonstration. It is expected that the system can contribute database construction for diagnostics and prognostics on facility health condition and systematic accumulation of know-how on operation and maintenance of plant.

  • PDF

수력발전소 정비변수 및 회전체 통합관리시스템 개발 (Development of an Integrated Management System for Maintenance Parameters and Rotary Machine of Hydro-power Plant)

  • 신성환;박진호;윤두병;손기성
    • 한국소음진동공학회논문집
    • /
    • 제22권6호
    • /
    • pp.574-581
    • /
    • 2012
  • Condition-based maintenance(CBM) has been used as a useful concept for optimizing maintenance plan and decreasing maintenance cost in several kinds of plant sites. This study introduced an example that developed an integrated management system for maintenance parameters and hydraulic turbine of hydro-power plant in order to improve its maintenance strategy as applying CBM techinique. The integrated management system consists of three parts. One is a hardware part including PDA inspection system and several kind of precision measuring instruments. Another is a vibration monitoring system on hydraulic turbine. The other is a software part that takes charge of making hierarchy tree of maintenance parameters and their inspection route, managing accumulated database, assessing health condition of components, and supporting interface with other enterprise management system. The system has been installed at Chuncheon hydro-power plant for test and demonstration. It is expected that the system can contribute database construction for diagnostics and prognostics on facility health condition and systematic accumulation of know-how on operation and maintenance of plant.

발전용 고온 배관의 점검 및 실시간 변위감시 기술 (Technology of Inspection and Real-time Displacement Monitoring on Critical Pipe for Power Plant)

  • 현중섭;허재실;조선영;허정열;이성기
    • 대한기계학회논문집A
    • /
    • 제33권10호
    • /
    • pp.1177-1186
    • /
    • 2009
  • High temperature steam pipes of thermal power plant are subject to a severe thermal range and usually operates well into the creep range. Cyclic operation of the plant subjects the piping system to mechanical and thermal fatigue damages. Also, poor or malfunctional supports can impose massive loads or stress onto the piping system. In order to prevent the serious damage and failure of the critical piping system, various inspection methods such as visual inspection, computational analysis and on-line piping displacement monitoring were developed. 3-dimensional piping displacement monitoring system was developed with using the aluminum alloy rod and rotary encoder sensors, this system was installed and operated on the high temperature steam piping of "Y" thermal power plant successfully. It is expected that this study will contribute to the safety of piping system, which could minimize stress and extend the actual life of critical piping.