• Title/Summary/Keyword: Power Parameters

Search Result 5,769, Processing Time 0.038 seconds

Evaluation of Image Qualities for a Digital X-ray Imaging System Based on Gd$_2$O$_2$S(Tb) Scintillator and Photosensor Array by Using a Monte Carlo Imaging Simulation Code (몬테카를로 영상모의실험 코드를 이용한 Gd$_2$O$_2$S(Tb) 섬광체 및 광센서 어레이 기반 디지털 X-선 영상시스템의 화질평가)

  • Jung, Man-Hee;Jung, In-Bum;Park, Ju-Hee;Oh, Ji-Eun;Cho, Hyo-Sung;Han, Bong-Soo;Kim, Sin;Lee, Bong-Soo;Kim, Ho-Kyung
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.253-259
    • /
    • 2004
  • in this study, we developed a Monte Carlo imaging simulation code written by the visual C$\^$++/ programing language for design optimization of a digital X-ray imaging system. As a digital X-ray imaging system, we considered a Gd$_2$O$_2$S(Tb) scintillator and a photosensor array, and included a 2D parallel grid to simulate general test renditions. The interactions between X-ray beams and the system structure, the behavior of lights generated in the scintillator, and their collection in the photosensor array were simulated by using the Monte Carlo method. The scintillator thickness and the photosensor array pitch were assumed to 66$\mu\textrm{m}$ and 48$\mu\textrm{m}$, respertively, and the pixel format was set to 256 x 256. Using the code, we obtained X-ray images under various simulation conditions, and evaluated their image qualities through the calculations of SNR (signal-to-noise ratio), MTF (modulation transfer function), NPS (noise power spectrum), DQE (detective quantum efficiency). The image simulation code developed in this study can be applied effectively for a variety of digital X-ray imaging systems for their design optimization on various design parameters.

The Study of Operating Conditions by Establishing Density Currents Generator for Improving of Water Quality on Lake Water - With Focus on DO and Water Temperature - (호소수의 수질개선을 위한 DCG 설치시 운전조건에 관한 연구 - DO와 수온을 중심으로 -)

  • Lee, Young-Shin;Han, Kyung-Hee;Kim, Young-Kyu;An, Hyung-Chul;Shin, Sung-Woo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.4
    • /
    • pp.286-294
    • /
    • 2014
  • The purpose of this study is to investigate the effects of applying density current generator (hereafter referred to as DCG to large lakes on the operating conditions of DCG, de-stratification, water quality improvement and inhibition of algae occurrence. As a result of a survey conducted to derive the optimum operating parameters of DCG in a condition to minimize eco-toxicity, the following conclusions were obtained. During the survey period, a marked stratification appeared in September to October 2011 and May 2012. At this time, the average depth of water to form thermocline was found to be $5{\pm}2$ m, so the location of discharge port for the operation of DCG was determined to be about 5 m below from the surface. To minimize the adverse effects of benthos and obtain the effect of water mixture at the time of water circulation, the mixing ratio of surface water and deep water was designed to be 3:1 by means of ecotoxicological assessment on the DCG operating characteristics. To select the appropriate operating hours for DCG, DCG was operated by 12 hr, 24 hr, 36 hr and 48 hr. As its result, the formation of thermocline did not occur during the operation of 36 hr. Also, It was effected that start reoperating from 3rd day after stop 2days under the condition of operated during 36 hr with calculated power consumption. Under the above conditions, the results of DO and water temperature analysis during the operation of DCG showed that the stratification, which was distinct previously, appeared to be weak, and relatively lower levels than those before operation were found as a result of water quality analysis on COD and chlorophyll-a, which leads to the conclusion that the water body is maintained at a stable condition due to the circulation of water by the occurrence of density current resulting from the operation of DCG.

Excimer-Based White Phosphorescent OLEDs with High Efficiency

  • Yang, Xiaohui;Wang, Zixing;Madakuni, Sijesh;Li, Jian;Jabbour, Ghassan E.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1520-1521
    • /
    • 2008
  • There are several ways to demonstrate white organic light emitting diodes (OLEDs) for displays and solid state lighting applications. Among these approaches are the stacked three primary or two complementary colors light-emitting layers, multiple-doped emissive layer, and excimer and exciplex emission [1-10]. We report on white phosphorescent excimer devices by using two light emitting materials based on platinum complexes. These devices showed a peak EQE of 15.7%, with an EQE of 14.5% (17 lm/W) at $500\;cd/m^2$, and a noticeable improvement in both the CIE coordinates (0.381, 0.401) and CRI (81). Devices with the structure ITO/PEDOT:PSS/TCTA (30 nm)/26 mCPy: 12% FPt (10 nm) /26 mCPy: 2% Pt-4 (15 nm)/BCP (40 nm)/CsF/Al [device 1], ITO/PEDOT:PSS/TCTA (30 nm)/26 mCPy: 2% Pt-4 (15 nm)/26 mCPy: 12% FPt (10 nm)/BCP (40 nm)/CsF/Al [device 2], and ITO/PEDOT:PSS/TCTA (30 nm)/26 mCPy: 2% Pt-4: 12% FPt (25 nm)/BCP (40 nm)/CsF/Al [device 3] were fabricated. In these cases, the emissive layer was either the double-layer of 26 mCPy:12% FPt and 15 nm 26 mCPy: 2% Pt-4, or the single layer of 26mCPy with simultaneous doping of Pt-4 and FPt. Device characterization indicates that the CIE coordinates/CRI of device 2 were (0.341, 0.394)/75, (0.295, 0.365)/70 at 5 V and 7 V, respectively. Significant change in EL spectra with the drive voltage was observed for device 2 indicating a shift in the carrier recombination zone, while relatively stable EL spectra was observed for device 1. This indicates a better charge trapping in Pt-4 doped layers [10]. On the other hand, device 3 having a single light-emitting layer (doped simultaneously) emitted a board spectrum combining emission from the Pt-4 monomer and FPt excimer. Moreover, excellent color stability independent of the drive voltage was observed in this case. The CIE coordinates/CRI at 4 V ($40\;cd/m^2$) and 7 V ($7100\;cd/m^2$) were (0.441, 0.421)/83 and (0.440, 0.427)/81, respectively. A balance in the EL spectra can be further obtained by lowering the doping ratio of FPt. In this regard, devices with FPt concentration of 8% (denoted as device 4) were fabricated and characterized. A shift in the CIE coordinates of device 4 from (0.441, 0.421) to (0.382, 0.401) was observed due to an increase in the emission intensity ratio of Pt-4 monomer to FPt excimer. It is worth noting that the CRI values remained above 80 for such device structure. Moreover, a noticeable stability in the EL spectra with respect to changing bias voltage was measured indicating a uniform region for exciton formation. A summary of device characteristics for all cases discussed above is shown in table 1. The forward light output in each case is approximately $500\;cd/m^2$. Other parameters listed are driving voltage (Bias), current density (J), external quantum efficiency (EQE), power efficiency (P.E.), luminous efficiency (cd/A), and CIE coordinates. To conclude, a highly efficient white phosphorescent excimer-based OLEDs made with two light-emitting platinum complexes and having a simple structure showed improved EL characteristics and color properties. The EQE of these devices at $500\;cd/m^2$ is 14.5% with a corresponding power efficiency of 17 lm/W, CIE coordinates of (0.382, 0.401), and CRI of 81.

  • PDF

Fluticasone Propionate and Beclomethasone Dipropionate in Asthmatic Patients (천식환자에서 Fluticasone propionate와 Beclomethasone dipropionate의 치료효과 비교)

  • Yang, Dong-Kyu;Kim, Young-Sam;Ahn, Chul-Min;Ko, Won-Ki;Chang, Joon;Kim, Sung-Kyu;Lee, Won-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.47 no.5
    • /
    • pp.629-641
    • /
    • 1999
  • Background: Corticosteroid is most potent and effective anti-inflammatory medication currently available and inhaled form has been used in the long-tenn control of asthma. Fluticasone propionate(Flixotide/Flovent: FP) is highly potent and topically active inhaled corticosteroid and has at least twice the potency of beclomethasone dipropionate(BDP) in the control of asthma. The aim of this study was to compare the efficacy of FP and BDP in several aspects. Method: Fifty patients with asthma were treated in a randomized, parallel group study of 4 weeks duration. During 2-week run-in period $\beta_2$-agonist was administered. After run-in period, FP $500{\mu}g/day$ was administered via Diskhaler or BDP $800{\mu}g/day$ via reservoir dry-power device. During the run-in and treatment period, morning and evening peak expiratory flow rate(PEFR) were measured daily. Daytime and nighttime asthma symptoms, daytime and night-time rescue bronchodilator use were checked daily. $FEV_{1.0}$ and FVC were measured biweekly in both groups. Results: Three patients treated with FP and seven patient treated with BDP were dropped out. Therefore forty patients completed the study. Morning and evening PEFR was increased and diurnal variation of PEFR decreased significantly in both groups. $FEV_{1.0}$ increased significantly in FP treatment group but not in BDP group. There were also improvements in daytime and night-time asthma symptoms, daytime and night-time rescue bronchodilator use in both groups after treatment There were no significant difference between groups in any of the efficacy parameters. Therapeutic effects were demonstrated earlier in patient treated with FP than BDP. Conclusion: In this study, $500{\mu}g/day$ fluticasone propionate was as effective as $800{\mu}g/day$ beclomethasone dipropionate in the control of asthma. Therapeutic effects were demonstrated earlier in patient treated with FP than BDP without adverse effect.

  • PDF

Preparation of Na-X and Na-A Zeolites from Coal Fly Ash in a Thermoelectric Power Plant and Comparison of the Adsorption Characteristics for Cu(II) with a Commercial Zeolite (화력발전소 석탄비산재를 이용한 Na-X와 Na-A 제올라이트 제조 및 상업용 제올라이트와의 Cu(II) 흡착 특성 비교)

  • Choi, Yu-Lim;Angaru, Ganesh Kumar Reddy;Kim, Dong-Su;Ahn, Hye-Young;Kim, Dae-Ho;Choi, Chi-Dong;Reddy, Kodoru Janardhan;Yang, Jae-Kyu;Chang, Yoon-Young
    • Applied Chemistry for Engineering
    • /
    • v.30 no.6
    • /
    • pp.749-756
    • /
    • 2019
  • Na-X and Na-A zeolites that give high adsorption capacity for heavy metals in an aqueous system were synthesized from the coal fly ash obtained from a thermoelectric power plant using a fusion method. The characteristics and Cu(II) adsorption capacity of the synthetic zeolites were also compared to those of using a commercial zeolite. For the selection of optimum conditions of zeolite synthesis, the effects of major parameters in the fusion method such as a dosage ratio of NaOH, aging time, hydrothermal reaction time, and also the dosage ratio of NaAlO2 (Na-A) on the characteristics and Cu(II) adsorption capacity of the synthetic zeolites were studied. For the analysis of characteristics of the synthetic zeolites, X-ray diffraction (XRD), cation exchange capacity (CEC), Brunaue-Emmett-Teller (BET) and scanning electron microscopy (SEM) were used. The optimum conditions for the synthesis of zeolites with a high adsorption capacity for cationic heavy metals including Cu(II) were the aging time of 6 h, hydrothermal reaction time of 6 h and NaOH and NaAlO2 dosage ratio of 1.5 and 0.5 (Na-A), respectively. According to the Langmuir isotherm test, maximum Cu(II) adsorption capacities of the synthetic and commercial Na-X and Na-A zeolites were found to be 90.1, 105.26, 102.05, and 109.89 mg/g, respectively. This indicates that the adsorption capacity of synthetic zeolites was comparable to commercial ones. The results of this study also suggest that the coal fly ash can be potentially used as a raw material for the zeolite synthesis.

Studies on Quality Changes and Antioxidant Activity During the Fermentation of the Salt Fermented Whangseoke (황석어(Collichthys nireatus Jordan et starks) 젓갈의 숙성과정 중 품질변화와 항산화작용에 관한 연구)

  • Kim, Ji-Sang;Moon, Gap-Soon;Lee, Kyung-Hee;Lee, Young-Soon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.35 no.2
    • /
    • pp.171-176
    • /
    • 2006
  • The effect of storage temperature on the quality and antioxidative activity Whangseoke sauce was studied over a period of 240 days. Fermented Whangseoke with $25\%$ salt were stored at $25^{\circ}C$. The quality change and antioxidant activity of Whangseoke in linoleic acid emulsion was evaluated with various parameters including acids values, peroxide values, TBA values, reducing sugar, brown color intensity, electron donating ability and reducing power at various time intervals for 240 days of storage. In general, it was observed, in all sample, that peroxide values, brown color intensity, electron donating ability and reducing power gradually increased, while reducing sugar decreased during storage at $25^{\circ}C$. The antioxidative activities of fermented Whangseoke were determined on tile linoleic acid emulsion system. The results showed that Whangseoke had antioxidant activity. These results suggest that antioxidant activity of Whangseoke seemed to influence by Maillard reaction products during the storage periods.

Influence of Helicobacter pylori Infection on Gastric Motility in Children and Adolescents with Functional Dyspepsia (기능성 소화불량 소아청소년에서 위 운동에 대한 Helicobater pylori 감염의 영향)

  • Ryoo, Eell;Nam, Yoo-Nee;Kweon, Chang-Kyu;Kang, Sung-Kil;Cho, Kang-Ho;Son, Dong-Woo;Tcha, Hann
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.12 no.2
    • /
    • pp.133-139
    • /
    • 2009
  • Purpose: In spite of many reports about Helicobacter pylori infection in children with functional gastrointestinal disorders, there are few reports about the influence of H. pylori infection to functional dyspepsia and gastric motility. Therefore, we studied the influence of H. pylori infection on gastric myoelectrical activity in children with functional dyspepsia. Methods: Between August 2006 and December 2008 upper gastrointestinal endoscopies with biopsies, the rapid urease test and/or $^{13}C$ urea breath test, and electrogastrography (EGG) were performed on 63 patients with histologic chronic gastritis; patients with chronic disorders were excluded. Comparisons about gastric myoelectrical activities were made between H. pylori-positive children (n=25) and H. pylorinegative children (n=38). Results: The percentage of pre- and post-prandial normogastria was relatively lower in H. pylori-positive children than H. pylori-negative children (80% vs. 65%, and 80% vs. 68%, respectively). Compared to H. pylori-negative children, H. pylori-positive children had lower postprandial predominant power (8.18${\pm}$22.36 dB and 32.20${\pm}$24.18 dB, respectively; p<0.01) and a lower power ratio (${\delta}P$; -1.28${\pm}$6.18 vs. +4.62${\pm}$5.93, respectively; p<0.01). Conclusion: It was suggested that the gastric myoelectrical activity in children with chronic gastritis can be influenced by H. pylori infection. Thus, this study indicates that H. pylori infection may be predictable in children with functional dyspepsia through analyzing the EGG parameters, and treatment may be considered in H. pylori-positive children with impaired gastric activity, especially in the lower prevalence area.

  • PDF

Plowing Performance in the Paddy Field Spread with Rice Straw in Spring (논의 볏짚 시용(施用)이 춘계리경작업(春季犁耕作業) 성능(性能)에 미치는 영향(影響))

  • Park, Woo Pung;Kim, Soung Rai
    • Journal of Biosystems Engineering
    • /
    • v.8 no.1
    • /
    • pp.9-16
    • /
    • 1983
  • This study was conducted to find out the effects of such parameters as specific draft resistance, slip rate, and fuel consumption rate on plowing performance in paddy fields spread with chopped rice straw. The plowing operation by an 8 P.S. power tiller was carried out in 6 different fields having the soil moisture content of 27~36 percent in dry basis in clay loam soil texture, and applying chopped rice straw of 10, 20, 30 and 60cm in length in the spring of 1982. The effects of soil hardness and moisture content on the plowing performance were also investigated. The results of the study are summarized as follows; 1. The minimum draft during the plowing operation was 110kg in the 30cm rice straw plot having the soil moisture content of 32 percent in dry basis. 2. The multiple regression equation of the specific draft(D) as a function of soil moisture content(M) and cutting length of rice straw(L) was obtained as follows. $D=14.1978-0.8565M+0.0661LxM-2.9685L+0.0133M^2+1.093L^2$ 3. In the 30cm rice straw plot with the soil moisture content of 32 percent in dry basis, the minimum specific draft resistance and the rate of slip were 0.35kg per $cm^2$ and 16 percent respectively. The specific draft resistance varied sensitively in accordance with the soil moisture content, and the slip rate of power tiller was dependent upon the cutting length of rice straw rather than the soil moisture content. 4. The highest plowing performance was 5.3 ares per hour at the soil moisture content of 35 percent and soil hardness of 10kg per $cm^2$. The relationship between the plowing performance and the soil moisture content was obtained by a quadratic equation. 5. The minimum fuel consumption rate in the plowing operation was recorded 6.5 liters per 10 ares in 30cm chopped rice straw plot with the soil moisture content of 32 percent in dry basis.

  • PDF

A Study on the Shaped-Beam Antenna with High Gain Characteristic (고이득 특성을 갖는 성형 빔 안테나에 대한 연구)

  • Eom, Soon-Young;Yun, Je-Hoon;Jeon, Soon-Ick;Kim, Chang-Joo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.1 s.116
    • /
    • pp.62-75
    • /
    • 2007
  • This paper describes a shaped-beam antenna for increasing the antenna gain of a radiating element. The proposed antenna structure is composed of an exciting element and a multi-layered disk array structure(MDAS). The stack micro-strip patch elements were used as the exciter for effectively radiating the electromagnetic power to the MDAS over the broadband, and finite metallic disk array elements - which give the role of a director for shaping the antenna beam with the high gain - were finitely and periodically layered onto it. The efficient power coupling between the exciter and the MDAS should be carried out in such a way that the proposed antenna has a high gain characteristic. The design parameters of the exciter and the MDAS should be optimized together to meet the required specifications to meet the required specifications. In this study, a shaped-beam antenna with high gain was optimally designed under the operating conditions with a linear polarization and the frequency band of $9.6{\sim}10.4\;GHz$. Two methods constructed using thin dielectric film and dielectric foam materials respectively were also proposed in order to implement the MBAS of the antenna. In particular, through the computer simulation process, the electrical performance variations of the antenna with the MDAS realized by the thin dielectric film materials were shown according to the number of disk array elements in the stack layer. Two kinds of antenna breadboard with the MDAS realized with the thin dielectric film and dielectric foam materials were fabricated, but experimentation was conducted only on the antenna breadboard(Type 1) with the MDAS realized with the thin dielectric film materials according to the number of disk array elements in the stack layer in order to compare it with the electrical performance variations obtained during the simulation. The measured antenna gain performance was found to be in good agreement with the simulated one, and showed the periodicity of the antenna gain variations according to the stack layer number of the disk array elements. The electrical performance of the Type 1 antenna was measured at the center frequency of 10 GHz. As the disk away elements became the ten stacks, a maximum antenna gain of 15.65 dBi was obtained, and the measured return loss was not less than 11.4 dB within the operating band. Therefore, a 5 dB gain improvement of the Type 1 antenna can be obtained by the MDAS that is excited by the stack microstrip patch elements. As the disk array elements became the twelve stacks, the antenna gain of the Type 1 was measured to be 1.35 dB more than the antenna gain of the Type 2 by the outer dielectric ring effect, and the 3 dB beam widths measured from the two antenna breadboards were about $28^{\circ}$ and $36^{\circ}$ respectively.

Effect of the Configuration of Contact Type Textile Electrode on the Performance of Heart Activity Signal Acquisition for Smart Healthcare (스마트 헬스케어를 위한 심장활동 신호 검출용 접촉식 직물전극의 구조가 센싱 성능에 미치는 영향)

  • Cho, Hyun-Seung;Koo, Hye-Ran;Yang, Jin-Hee;Lee, Kang-Hwi;Kim, Sang-Min;Lee, Jeong-Hwan;Kwak, Hwy-Kuen;Ko, Yun-Su;Oh, Yun-Jung;Park, Su-Youn;Kim, Sin-Hye;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.21 no.4
    • /
    • pp.63-76
    • /
    • 2018
  • The purpose of this study was to investigate the effect of contact type textile electrode structure on heart activity signal acquisition for smart healthcare. In this study, we devised six contact type textile electrodes whose electrode size and configuration were manipulated for measuring heart activity signals using computerized embroidery. We detected heart activity signals using a modified lead II and by attaching each textile electrode to the chest band in four healthy male subjects in a standing static posture. We measured the signals four times repeatedly for all types of electrodes. The heart activity signals were sampled at 1 kHz using a BIOPAC ECG100, and the detected original signals were filtered through a band-pass filter. To compare the performance of heart activity signal acquisition among the different structures of the textile electrodes, we conducted a qualitative analysis using signal waveform and size as parameters. In addition, we performed a quantitative analysis by calculating signal power ratio (SPR) of the heart activity signals obtained through each electrode. We analyzed differences in the performance of heart activity signal acquisition of the six electrodes by performing difference and post-hoc tests using nonparametric statistic methods on the calculated SPR. The results showed a significant difference both in terms of qualitative and quantitative aspects of heart activity signals among the tested contact type textile electrodes. Regarding the configurations of the contact type textile electrodes, the three-dimensionally inflated electrode (3DIE) was found to obtain better quality signals than the flat electrode. However, regarding the electrode size, no significant difference was found in performance of heart signal acquisition for the three electrode sizes. These results suggest that the configuration method (flat/3DIE), which is one of the two requirements of a contact type textile electrode structure for heart activity signal acquisition, has a critical effect on the performance of heart activity signal acquisition for wearable healthcare. Based on the results of this study, we plan to develop a smart clothing technology that can monitor high-quality heart activity without time and space constraints by implementing a clothing platform integrated with the textile electrode and developing a performance improvement plan.