• 제목/요약/키워드: Power Measurement

검색결과 4,630건 처리시간 0.029초

몬테카를로 시뮬레이션을 이용한 시운전 선속-동력 성능에 대한 불확실성 해석 (Uncertainty Analysis for Speed and Power Performance in Sea Trial using Monte Carlo Simulation)

  • 서대원;김민수;김상엽
    • 대한조선학회논문집
    • /
    • 제56권3호
    • /
    • pp.242-250
    • /
    • 2019
  • The speed and power performance of a ship is not only a guarantee issue between the ship owner and the ship-yard, but also is related with the Energy Efficiency Design Index (EEDI) regulation. Recently, International Organization for Standardization (ISO) published the procedure of the measurement and assessment for ship speed and power at sea trial. The results of speed and power performance measured in actual sea condition must inevitably include various uncertainty factors. In this study, the influence for systematic error of shaft power measurement system was examined using the Monte Carlo simulation. It is found that the expanded uncertainty of speed and power performance is approximately ${\pm}1.2%$ at the 95% confidence level(k=2) and most of the uncertainty factor is attributed to shaft torque measurement system.

변압기철손 측정시스템의 측정 불확도 (Review of the measurement uncertainty of Tr no-load loss measuring system)

  • 강택수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.139-141
    • /
    • 2005
  • For the reliable evaluation of the distribution and power transformer no-load loss measurement, measurement uncertainty of the transformer measuring system, consisted of current transformer, potential transformer and power metering equipment is required. In this paper, we describe the uncertainty of transformer measuring system based on ANSI/IEEE C57.12.90.

  • PDF

디지털 신호처리기를 이용한 전력계통 주파수 측정에 관한 연구 (A study on the Measurement of Power system Frequency using Digital Signal Processor)

  • 이정우;오용택
    • 조명전기설비학회논문지
    • /
    • 제25권2호
    • /
    • pp.113-119
    • /
    • 2011
  • A frequency in electrical power system changes by the load fluctuation in utility grid, has an influence on a connected generator, and ultimately brings a big trouble in the power system. Therefore, a quick measurement of system frequency and governor control of power system is a very important factor in the reliability and the economic feasibility. Electromagnetic frequency relays in the past had the large power consumption and the difficulty of accurate measurement. After Researched and developed digital relays are very affected by the noise and the distortion, and the recently developed Microprocessor relays have problems of expensive device and time when measuring the frequency at 50[ms]. In this study, An improve algorithm that measures the power system frequency quickly and accurately is suggested, simulated by using Matlab and programmed using C code through DSP6713 KIT. This algorithm is tested to the arbitrary voltage waveform input. The results show that the suggested algorithm is effective in the accurate and quick frequency measurements.

신호용 PEAK 전압 정밀검출에 관한 연구 (A Study on Accuracy Detection Method for Signal Peak Voltage)

  • 박호철;성형수;한승문;한정훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.2528-2530
    • /
    • 2000
  • In general, Diode makes a major role in electronic circuit. For example, switching of rectifier, cross current of switching rectifier, energy transfer of electronic element and reverse charge of capacitor, voltage insulation, energy feedback from load to power supply, and such as recovery of storaged energy. Generally, We regard power diode as ideal element, but it has a certain boundary actually, specially, We use diode for detecting circuit peak hold voltage signal. It has cut in voltage. It occurs error of measurement value namely. This error, below in region diode voltage drop (0.7v) measurement value is wholesome signal, Specially, We can not get precision data. Therefore, precision level is low between theoretical and measurement data because of error in actual circuit. Conclusionally, In this paper, We define the error concerning to the power diode characteristics which is used detecting of the minute signal, and recommend the method that minimize measurement error.

  • PDF

밀리와트 영역의 초음파 파워 정밀 측정 (Precision Measurement of Ultrasonic Power the Milliwatt Range)

  • 조문재;황철호;서상준;차일환
    • 한국음향학회지
    • /
    • 제9권2호
    • /
    • pp.25-33
    • /
    • 1990
  • 초음파를 완전 반사시킬 수 있는 반사용 target과 완전 흡수시킬 수 있는 흡음용 target을 이용하여, 이들 target에 가해진 방사음압을 전자저울로 측정하고 이로부터 밀리와트 영역의 초음파 파워를 결정할 수 있는 시스템을 구성하였다. 이 시스템 구성의 타당성 검토를 위해 완전 반사용 target과 완전 흡수용 target으로 구한 초음파 파워의 크기를 측정하였으며, 측정 시스템의 계통 오차 및 재현성 등에 대해 고찰하였다. 두가지 target을 각기 사용하여 측정한 초음파 파워의 차이는 2%의 상대 오차 이내에서 잘 일치하며, 시스템의 재현성은 10mW 이상의 초음파 파워에 대한 표준편차가 2%이하였다.

  • PDF

계통 연계형 태양광 발전시스템의 전력품질에 관한 연구 (A Study on the Power Quality of the Grid connected Photovoltaic Power System)

  • 최형범;김경철;황영록
    • 조명전기설비학회논문지
    • /
    • 제25권8호
    • /
    • pp.88-98
    • /
    • 2011
  • Development and use of renewable energy due to environmental problems and depletion of energy affect grid-connected power system around the world. Therefore this paper analyzes the characteristic of gird connected photovoltaic power generation system which it is available to connect the utility. Renewable energy photovoltaic power system has been linked to the system to analyze the impact of photovoltaic system. MATLAB / Simulink program is modeled and analyzed on power quality of a photovoltaic power plant. It is measured that power data for the Grid connected photovoltaic power plant with instantaneous measuring, 3sec measuring, 10min measuring for 7 days. Harmonic field measurement have shown that the harmonic contents of a waveform varies with time. A cumulative probability approach is the most commonly used method to solve time varying harmonics. so, it is used 50[%] cumulative probability approach. This paper provides an in depth analysis on power quality field measurement of the Grid connected photovoltaic power plant.

$LabVIEW^{TM}$를 이용한 고출력 가간섭광 계측 (A measurement of the high power coherent light using LabVIEWTM)

  • 황대석;최종운;이영우
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2003년도 춘계종합학술대회
    • /
    • pp.821-823
    • /
    • 2003
  • 산업 전반에 사용되는 수백W-수kW의 $CO_2$ 및 Nd:YAG 레이저광 출력측정 및 교정을 위해 정밀한 레이저 계측 장치를 제작하고 성능 평가 및 출력 측정을 위해 National Instrument사의 LabVIEW를 이용한 프로그램을 작성하였다. 레이저광의 출력측정을 위해 전원 공급기와 두 대의 DVM, 디지털 카운터를 GPIB를 통해 PC에 연결하였고 이를 이용해 데이터를 수집하여 그 결과를 분석하였다.

  • PDF

농업저수지 자동 수위관측기 개발 - 저전력 원격제어 수위관측기 중심 - (Development of Automatic Water Level Measurement System for the Irrigation Reservoir - Study on Low Power and Remote Controlled Water Level Measurement System -)

  • 김진택;주욱종;최승철
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2003년도 학술발표논문집
    • /
    • pp.491-494
    • /
    • 2003
  • An Automatic Water Level Measurement System has been developed in this study. It has the characteristics that it use lower power and solar power and it has the ability of sending data and remote-controlled by wireless MODEM this system was set up in the experimental site and was tested. Also, the management system for the water level data has been developed and will be used by instruments administrating reservoirs.

  • PDF

문직운전계통을 포함한 전럭계통에서의 상태주정에 관한 연구 (Interconnected AC/DC System)

  • 김준현;박건수;이종범
    • 대한전기학회논문지
    • /
    • 제37권1호
    • /
    • pp.1-9
    • /
    • 1988
  • This paper descibes a method for the state estimation in power systems with interconnected AC/DC system. The state values in interconnected AC/DC system are estimated using measurement values with the pseudo measurement so that the number of telemetering measurement can be reduced. Especially, the state values in AC system are estimated through hierarchical method after system decomposition including superposition bus was formed for the state estimation in large-scale power systems. The results of the application to the two model power systems show the dffectiveness of the presented algorithms.

  • PDF

DUMMY 모선을 고려한 상태추정 측정점선정 알고리즘에 관한 연구 (A Study on Measurement Selection Algorithm for Power System State Estimation under the consideration of Dummy Buses)

  • 이태식;문영현;함완균;권태원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.406-410
    • /
    • 1991
  • This paper presents an improved algorithm of optimal measurement system design with a reliability evaluation method for large power system. The proposed algorithm is developed to consider the dummy bus and to achieve highest accuracy of the state estimator as well with the limited Investment cost. The dummy bus in the power system is impossible to install measurement meter, while real and reactive power measurement values are exactly zero. Thus, the effect on these dummy bus measurements is considered in the proposed algorithm. On the other hand, P/C model is developed by taking advantage of the matrix sparsity. The improved program is successfully tested for KEPCO system with PSS/E lineflow calculated data package.

  • PDF