• 제목/요약/키워드: Power Measurement

검색결과 4,625건 처리시간 0.035초

Artificial Rainfall Test of the Engineered Cover Barriers for Near Surface Disposal of LILW

  • Park, Jin-Beak;Park, Se-Moon;Kim, Chang-Lak
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2003년도 가을 학술논문집
    • /
    • pp.306-314
    • /
    • 2003
  • Engineered barrier test facility is specially designed to demonstrate the performance of engineered barrier system for the near-surface disposal facility under the domestic environmental conditions. Comprehensive measurement systems for the water content, temperature, matric potential are installed within each test cell. In this study, short-term monitoring of the behavior of multi-layered cover system is implemented with artificial rainfall system. The periodic measurement data are collected and analyzed by a dedicated database management system, and provide a basis for performance verification of the disposal cover design.

  • PDF

3차원 레이저 스캐너용 ND 필터의 시뮬레이션 (Simulation of ND Filter for Terrestrial Laser Scanner)

  • 양수효;오동근;정중연
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2009년도 춘계학술발표회 논문집
    • /
    • pp.65-73
    • /
    • 2009
  • The terrestrial laser scanner measures the signal delay time of electronic circuit in EDM(Electronic Distance Measurement) Module for distance measurement. To measure signal delay time precisely, transmitting laser beam of terrestrial laser scanner is divided optically. Therefore, 10% of the laser beam power is entered into the electronic circuit and the others go out through lens. But, measure of delay time is severe in the laser scanner system that the laser beam power is changed dynamically by reflectance of a object, because characters like gain of electronic circuit involving APD(Avalanche Photo Diode) and so on are changed by incident laser beam. Therefore, we adapt ND(Neutral Density) filter that has grid pattern to the laser scanner system to keep constant the incident laser beam power. In this paper, we propose the simulation program for efficient design of ND filter pattern. Finally, to affirm simulation program, we conduct the experimental test of simulated ND filter that has linearly transmittance change, and we consider the experiment result.

  • PDF

전력측정을 위한 전자보상 전류센서에 관한 연구 (A Study on An Electronically Compensated Current Sensor for Measurement of Power)

  • 박영태;권성원;이진호;유광민
    • 센서학회지
    • /
    • 제4권3호
    • /
    • pp.1-8
    • /
    • 1995
  • 본 연구에서는 전력의 정확한 측정을 위하여 전자적으로 보상된 전류센서에 대하여 기술하였다. 궤환권선과 전자보상을 사용하여 전류센서를 개선하는 방법을 제안하였다. 개선된 전류센서와 함께 전력측정에 사용되는 전력 트랜스듀서를 제작하고 그 특성을 평가하였다.

  • PDF

전력용 변압기에서의 초음파 노이즈 (Ultrasonic Noises in Power Transformer)

  • 권동진;정길조;최인혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2305-2307
    • /
    • 1999
  • Partial discharge measurement using a ultrasonic technique allows us to detect degradation of the electrical insulation in a power transformer. However, The ultrasonic measurement studies don't offer a good solution in operating conditions. In this paper, we investigated characteristics of ultrasonic noise caused by a 345kV power transformer under operating conditions. The ultrasonic noises generated by corona in air, vibration of core, pump and fan, etc. An ultrasonic frequency caused by corona in air was appeared 9 and 18[MHz] at the outside wall of the transformer. And a spectra of core vibration was detected below 2.5[kHz]. These spectrum were compared with 20 $\sim$ 200[kHz] of the internal partial discharge in the model transformer.

  • PDF

22.9[kV] 배전선로 주변의 전장과 자장의 분포 (Profiles of Electric and Magnetic Fields around 22.9[kV] Distribution Lines)

  • 이복희;;박종순;길형준
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제13권2호
    • /
    • pp.178-178
    • /
    • 1999
  • In recent years, the electromagnetic environments are varied with the increase of power consumption and the spread of household electric appliances. Most of the interests to date have concentrated in the area of human health effects associated with exposure to power frequency electric and magnetic fields, and thus the precise measurement and analysis are required. In this paper, the measurements and analysis of the extremely low frequency(ELF) electric and magnetic fields produced by actual 22.9[kV] distribution lines were performed. The experiments have been carried out by lateral profile, and the theoretical analyses were made by use of FIELDS program for the sate of comparison with the experimental data. Electric and magnetic field intensity were strong under power distribution lines, and were inversely proportional to lateral distance. The profiles of electric and magnetic fields were M and ∩ shapes, respectively, and the measured data were good in agreement with the theoretical results. Both the electric and magnetic field intensity were increased with increasing the measurement height.

다채널 바이오텔레미터 개발을 위한 전용 IC 및 시스템 제작 (Manufacture of Custom IC and System for Multi-channel Biotelemeter)

  • 서희돈;박종대
    • 전자공학회논문지B
    • /
    • 제31B권8호
    • /
    • pp.172-180
    • /
    • 1994
  • Implantable biotelemetry systems are indispensable tools not only in animal research but also in clinical medicine as such systems enable the acquisition of otherwise unavailable physiological data. We present the manufacture of CMOS IC and its system for implantable multichannel biotelemeter system. The internal circuits of this system are designed not only to achieve as multiple functions and low power dissipation as possible but also to enable continuous measurement of physiological data. Its main functions are to enable continuous measurement of physiological data and to accomplish on-off power swiching of an implantable battery by receiving appropriate commanc signals from an external circuit. The implantable circuits of this system are designed and fabricated on a single silicon chip using $1.5\mu$m n-well CMOS process technology. The total power dissipation of implantable circuits for a continuous operation was 6.7mW and for a stand-by operation was 15.2$\mu$ W. This system used together with approriate sensors is expected to contribute to clinical medicine telemetry system of measuring and wireless transmitting such significant physiological parameters as pressure pH and temperature.

  • PDF

PERUPS (PERFORMANCE UPGRADE SYSTEM) FOR ON-LINE PERFORMANCE ANALYSIS OF A NUCLEAR POWER PLANT TURBINE CYCLE

  • KIM SEONGKUN;CHOI KWANGHEE
    • Nuclear Engineering and Technology
    • /
    • 제37권2호
    • /
    • pp.167-176
    • /
    • 2005
  • We developed the PERUPS system to aid the on-line performance analysis for the turbine cycle of the YongGwang 3 and 4 nuclear power plants. Procedure of measurement validation is included in the performance calculation to obtain heat balance. Precision of on-line performance calculation is increased via practical modifications of standard calculation algorithms based on the PTC (Performance Test Code). The proposed system also provides useful Web-based aids for performance analysis, including performance data management, a graphic viewer for heat balance and turbine expansion lines, and synthesized reports of performance.

변전소 고조파 측정 및 분석에 관한 연구 (A Study on Measurement and Analysis of Harmonics in Substation)

  • 한무호;박태준;이성희;이치환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.438-441
    • /
    • 2001
  • Nonlinear loads change the sinusoidal nature of the ac power current, thereby resulting in the flow of harmonic currents in the ac power system that can cause interference with communication circuits and other type of equipment. To minimize the damage, it is needed to limit harmonics current and voltage. Harmonic measurement system was developed to measure individual voltage and current harmonic continuously and save harmonic data on computer. We measured all 154kV feeders in a steel making company substation. Voltage and current distortion limits for general transmission systems was suggested We found some feeders exceeded current distortion limits. As result voltage harmonic exceeded standard limits.

  • PDF

고속전철 전력변환장치에서의 고조파 계측 및 분석 (Harmonics Measurement and Analysis for Power Electronic Equipments of Korea High Speed Train Prototype)

  • 이태형;장동욱;박춘수;목진용;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1382-1384
    • /
    • 2004
  • It is essential to evaluate harmonic characteristics of high speed train using power electronics equipment such as converter-driven motor drives, battery chargers and auxiliary power supplies. The purpose of this study is to measure and analyze harmonics characteristics of korea high speed train prototype. This paper presents result of harmonics measurement and analysis of harmonics characteristics in terms of loading, speed and operation mode.

  • PDF

고조파전류 측정에 근거한 국내 고조파 관리기준 검토 (Examination of the domestic harmonic standard introduction based on measurement of harmonic current)

  • 박용업;강문호;이남우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.539-540
    • /
    • 2007
  • In order to increase an efficiency of electric machine, the power electric devices are rapidly increasing of late. These electric components are mainly caused to lower of power quality. To take precautions against lower of power quality, the advanced countries already made effort to control of harmonic level. For these harmonic control of advanced countries have applied harmonic planning level, emission of harmonic based on the technical calculation and experiment. In this paper, we have investigated the introduction abroad advanced country standard through compared IEEE, IEC with the real measurement of domestic harmonic level.

  • PDF