• 제목/요약/키워드: Power Measurement

검색결과 4,625건 처리시간 0.033초

Leak Evaluation for Power Plant Valve Using Multi-Measuring Method

  • Lee, Sang-Guk;Park, Jong-Hyuck;Kim, Young-Bum
    • 비파괴검사학회지
    • /
    • 제28권6호
    • /
    • pp.469-476
    • /
    • 2008
  • Condition based maintenance(CBM) for the preventive diagnosis of important equipments related to safety or accident in power plant is essential by using the suitable methods based on actual power plant conditions. To improve the reliability and accuracy of the measured value at the minute leak situation, and also to monitor continuously internal leak condition of power plant valve, the development of a diagnosis and monitoring technique using multi-measuring method should be performed urgently. This study was conducted to estimate the feasibility of multi-measuring method using three different methods such as acoustic emission(AE) method, thermal image measurement and temperature difference$({\Delta}T)$ measurement that are applicable to internal leak diagnosis for the power plant valve. From the experimental results, it was suggested that the multi-measuring method could be an effective way to precisely diagnose and evaluate internal leak situation of valve.

컴퓨터를 이용한 전력 계측기 시스템 개발 (Development of Power Measurement System Using Computer)

  • 김태성;이우기;오수홍;오무송;최장주
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1998년도 춘계학술대회 논문집
    • /
    • pp.301-305
    • /
    • 1998
  • The Power measurement that can measure a single quantity does not smooth to install a system, and are not convenient to use. These measuring values are vary difficult for mutual operation and analyzing, and that have too many problems to compile measured databases. If each single measured values are mutual assist, correction and reform, the system will be able to be improved by minimizing differences between measure quantities and as making many different measurement system (Voltage, Current, Power and Resistor) is installed in one system. This study is useful to develope the power measurement system that is easier to analyze and management by database all of the parameter values because the power measurement system is able to be interbased with PC as requirement of industralization and information age.

  • PDF

음향파워 측정 시 오차에 대한 고찰 (A Study on the Errors at the Measurement of Sound Power)

  • 나혜중;임병덕
    • 한국소음진동공학회논문집
    • /
    • 제22권10호
    • /
    • pp.917-924
    • /
    • 2012
  • Noise power of large machineries, such as textile looms, winders, and twisting machines, is often measured in a reverberant space because they cannot be installed and operated in an anechoic chamber due to their size, weight, and operating conditions. Factors affecting the measurement error of an in-situ noise power measurement include the nonuniform reverberation time and the direction of sound intensity vector which is usually regarded as normal to the measurement surface. In this study errors due to these factors are estimated with the aid of numerical simulation based on the ray-tracing technique. The averaging of reverberation times measured at several points on the measurement surface is suggested to reduce the errors from nonuniform absorption. Also the direction cosine of each surface element is taken into account, which as a whole is represented as a solid angle of the measurement surface.

안테나 이득을 고려한 EIRP 측정 방법에 관한 연구 (The study on the EIRP measurement methods considering Antenna Gain)

  • 김동호;최동근;신찬수;신호섭;김남
    • 한국전자파학회:학술대회논문집
    • /
    • 한국전자파학회 2003년도 종합학술발표회 논문집 Vol.13 No.1
    • /
    • pp.555-559
    • /
    • 2003
  • Recently, in accordance with the commercialization of novel radio frequency utilization technologies, the radiated power must be rigorously limited for the purpose of protection of wireless facilities against frequency jamming or interference and for maintaining the quality of communication service. At present, the output power is measured from the conducted power for the domestic measurement criterion but is not a real radiated power and inaccurate. So, it is peformed to survey the more precisely accurate measurement scheme and analyze its criterion and methodology in comparison with foreign one. As a result of surveying and analyzing, it is concluded that the U.S. and E.U. is actually using the measurement method in consideration of terms of the Equivalent Isotropic Radiated Power(EIRP) and Effective Radiated power(ERP). In case of the frequency below 1 GHz, the half wave-length dipole antenna is used to measure the ERP and above 1 GHz the horn antenna as a reference antenna is used to measure the EIRP. Therefore, for the domestic purpose it is also necessary to take EIRP and ERP into consideration as a measurement criterion in order to make an accurate measurement and regulation.

  • PDF

개별 전로 전력 계측을 위한 디지털 신호처리 프로세서 기반 전력 관제 시스템의 제작 및 평가 (Fabrication and Evaluation of Digital Signal Processor for Multi-Lane Energy Measurement System)

  • 김근준;강봉순
    • 전기전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.619-623
    • /
    • 2018
  • 사회의 발달로 인하여 전력에 대한 수요가 증가함과 동시에 전력의 품질 관리가 중요한 문제로 부상하였다. 이러한 전력관리를 효율적으로 수행하기 위하여 본 논문에서는 다선로 전력 계측을 위한 DSP 기반 전력 측정 시스템을 제안한다. 종래의 전력 계측 시스템이 하나의 선로의 전력만을 측정 할 수 있었기 때문에, 개별 선로에 대한 전력 품질 측정을 위해서는 선로마다 전력 품질 측정 장치가 필요로 하였으며 이는 비용적인 문제로 인하여 시스템의 실제 구현이 불가능한 구조였다. 본 논문에서 제안하는 시스템은 디지털 신호 처리 알고리즘을 이용하여 최대 12개소의 전력 품질을 실시간 계측 할 수 있는 시스템을 제안하며, 이를 토대로 한 시제품을 한국전기연구원의 공인시험 성적서를 통하여 그 성능을 평가 받았다. 성능 시험결과 정밀 계측의 오차 범위 ${\pm}0.3%$의 우수한 성능임을 평가 받았다.

고전압 펄스신호 측정용 분압기의 온도보상에 관한 실험 (Experimental Analysis on Temperature Compensation of Capacitive Voltage Divider for a Pulsed High Voltage Measurement)

  • 장성덕;손윤규;권세진;오종석;조무현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1530-1533
    • /
    • 2005
  • Total 12 units of high power klystron-modulator systems as microwave source is under operation for 2.5-GeV electron linear accelerator in Pohang Light Source(PLS) linac. RF power and beam power of klystron are precisely measured for the effective control of electron beam. A precise measurement and measurement equipment with good response characteristics are required for this. Input power of klystron is calculated from the applied voltage and the current on its cathode. Tiny measurement error severely effects RF output power value of klystron. Therefore, special care is needed to measure precise beam voltage. Capacitive voltage divider(CVD) unit is intended for the measurement of beam voltage of 400 kV generated from the pulsed klystron-modulator system. Main parameter to determine the standard capacitance in the high arm of CVD is dielectric constant of insulation oil. Therefore CVD should be designed to have a minimum capacitance variation due to voltage, frequency and temperature in the measurement range. This paper will discuss the analysis of capacitive voltage divider for a pulsed high-voltage measurement, and the empirical relations between capacitance and oil temperature variation.

  • PDF

근접 전계 시험 시설을 이용한 능동 위상 배열 안테나 송신 빔 패턴 측정 (Transmit-Beam Pattern Measurement of the Active Phased-Array Antenna Using Near-Field Measurement Facility)

  • 채희덕;김한생;이동국;정명득;박종국
    • 한국전자파학회논문지
    • /
    • 제22권12호
    • /
    • pp.1155-1164
    • /
    • 2011
  • 본 논문에서는 국내 최초로 개발되는 함상용 중거리 레이더에 사용되는 능동 위상 배열 안테나의 송신 빔 특성을 근접 전계 시험으로 측정하는 방안에 대하여 제시하였다. 측정하고자 하는 능동 위상 배열 안테나는 고출력 송신 빔을 펄스 형태로 방사하기 때문에 저출력의 연속적인 파형을 사용하는 일반적인 근접 전계 시험 시설에서는 측정하기 어렵다. 그래서 본 논문에서는 고출력 송신 시에도 견딜 수 있도록 설계된 근접 전계 시험 시설과 펄스 모드 측정을 지원하는 Agilent사의 PNA-X 네트웍 분석기를 이용한 근접 전계 시험으로 펄스 형태의 고출력 송신 빔을 방사하는 능동 위상 배열 안테나를 측정하는 방안에 대하여 제시하였고, 실제 개발된 능동 위상 배열 안테나의 고출력 송신 빔 패턴을 근접 전계 시험으로 측정하였다. 또한, 능동 위상 배열 안테나의 송신 특성인 EIRP(Effective Isotropic Radiated Power)를 측정하였고, 수학적인 계산을 통해 예측한 EIRP 값과 비교한 결과 0.1 dB의 오차 내에서 동일함을 확인하였다.

NOVC형식 하이브리드 자동차의 최고 출력측정방법 연구 (A Study on Maximum Power Measurement Method for NOVC-type Hybrid Electric Vehicle)

  • 김주원;용기중
    • 자동차안전학회지
    • /
    • 제10권2호
    • /
    • pp.36-42
    • /
    • 2018
  • UNECE/WP29/GRPE/EVE has recently defined that the power of a hybrid electric vehicle is the system power. Although a method for measuring the maximum power of a hybrid electric vehicle is presented by KATRI, it does not consider charging and discharging characteristics of traction batteries. This study provides a maximum power measurement method which reflects the charging and discharging characteristics of traction batteries in NOVC-HEVs (Not Off Vehicle Charging-Hybrid Electric Vehicles). Both methods are compared with regard to the output measurement results.

Real-Time Monitoring and Analysis of Power Systems with Synchronized Phasor Measurements

  • Kim, Hong-Rae
    • 조명전기설비학회논문지
    • /
    • 제21권9호
    • /
    • pp.101-108
    • /
    • 2007
  • State estimators are used to monitor the operating states of power systems in modern EMS. It iteratively calculates the voltage profile of the currently operating power system with voltage, current, and power measurements gathered from the entire system. All the measurements are usually assumed to be obtained simultaneously. It is practically impossible, however, to maintain the synchronism of the measurement data. Recently, phasor measurements synchronized via satellite are used for the operation of these power systems. This paper describes the modified state estimator used to support the processing of synchronized phasor measurements. Synchronized phasor measurements are found to provide synchronism of measurement data and improve the accuracy/redundancy of the measurement data for state estimation. The details of the developed state estimation program and some numerical results of operation are presented.

화력발전소 주배관 3차원 변위측정시스템 개발 (Development of 3-D. Displacement Measurement System for Critical Pipe of Fossil Power Plant)

  • 송기욱;현중섭;하정수;조선영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1198-1205
    • /
    • 2003
  • Most domestic fossil power plant have exceeded 100,000 hours of operation with the severe operating condition. Among the critical components of fossil power plant, high temperature steam pipe system have had a many problems and damage from unstable displacement behavior because of frequent start up and shut down. In order to prevent the serious damage and failure of the critical pipe system in fossil power plant, 3-dimensional displacement measurement system were developed for the on-line monitoring system. 3-D Measurement system was developed with using the LVDT type sensor and rotary encoder type sensor, this system was installed and operated on the real power plant successfully. In the future time, network system of on-line diagnosis for critical pipe will be designed.

  • PDF