• 제목/요약/키워드: Power Loss Sensitivity

검색결과 124건 처리시간 0.026초

A Novel Photonic Crystal Fiber Sensor with Three D-shaped Holes Based on Surface Plasmon Resonance

  • Bing, Pibin;Sui, Jialei;Huang, Shichao;Guo, Xinyue;Li, Zhongyang;Tan, Lian;Yao, Jianquan
    • Current Optics and Photonics
    • /
    • 제3권6호
    • /
    • pp.541-547
    • /
    • 2019
  • A novel photonic crystal fiber (PCF) sensor with three D-shaped holes based on surface plasmon resonance (SPR) is analyzed in this paper. Three D-shaped holes are filled with the analyte, and the gold film is deposited on the side of three planes. The design of D-shaped holes with outward expansion can effectively solve the uniformity problem of metallized nano-coating, it is beneficial to the filling of the analyte and is convenient for real-time measurement of the analyte. Compared with the hexagonal lattice structure, the triangular arrangement of the clad air holes can significantly reduce the transmission loss of light and improve the sensitivity of the sensor. The influences of the air hole diameter, the distance between D-shaped holes and core, and the counterclockwise rotation angle of D-shaped holes on sensing performance are studied. The simulation results show that the wavelength sensitivity of the designed sensor can be as high as 10100 nm/RIU and the resolution can reach 9.9 × 10-6 RIU.

Optimal Voltage and Reactive Power Scheduling for Saving Electric Charges using Dynamic Programming with a Heuristic Search Approach

  • Jeong, Ki-Seok;Chung, Jong-Duk
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.329-337
    • /
    • 2016
  • With the increasing deployment of distributed generators in the distribution system, a very large search space is required when dynamic programming (DP) is applied for the optimized dispatch schedules of voltage and reactive power controllers such as on-load tap changers, distributed generators, and shunt capacitors. This study proposes a new optimal voltage and reactive power scheduling method based on dynamic programming with a heuristic searching space reduction approach to reduce the computational burden. This algorithm is designed to determine optimum dispatch schedules based on power system day-ahead scheduling, with new control objectives that consider the reduction of active power losses and maintain the receiving power factor. In this work, to reduce the computational burden, an advanced voltage sensitivity index (AVSI) is adopted to reduce the number of load-flow calculations by estimating bus voltages. Moreover, the accumulated switching operation number up to the current stage is applied prior to the load-flow calculation module. The computational burden can be greatly reduced by using dynamic programming. Case studies were conducted using the IEEE 30-bus test systems and the simulation results indicate that the proposed method is more effective in terms of saving electric charges and improving the voltage profile than loss minimization.

ESTABLISHMENT OF A SEVERE ACCIDENT MITIGATION STRATEGY FOR AN SBO AT WOLSONG UNIT 1 NUCLEAR POWER PLANT

  • Kim, Sungmin;Kim, Dongha
    • Nuclear Engineering and Technology
    • /
    • 제45권4호
    • /
    • pp.459-468
    • /
    • 2013
  • During a station blackout (SBO), the initiating event is a loss of Class IV and Class III power, causing the loss of the pumps, used in systems such as the primary heat transporting system (PHTS), moderator cooling, shield cooling, steam generator feed water, and re-circulating cooling water. The reference case of the SBO case does not credit any of these active heat sinks, but only relies on the passive heat sinks, particularly the initial water inventories of the PHTS, moderator, steam generator secondary side, end shields, and reactor vault. The reference analysis is followed by a series of sensitivity cases assuming certain system availabilities, in order to assess their mitigating effects. This paper also establishes the strategies to mitigate SBO accidents. Current studies and strategies use the computer code of the Integrated Severe Accident Analysis Code (ISAAC) for Wolsong plants. The analysis results demonstrate that appropriate strategies to mitigate SBO accidents are established and, in addition, the symptoms of the SBO processes are understood.

손실감도를 이용한 계통손실 최적화에 대하여 (On The Optimal Generation Using The Loss Sensitivities Derived by Angle Reference Transposition)

  • 양성덕;이상중
    • 조명전기설비학회논문지
    • /
    • 제19권1호
    • /
    • pp.59-63
    • /
    • 2005
  • 전력계통을 효율적으로 운용하려면 관련량을 정확하고 신속히 계산하는 좋은 알고리즘이 필요하다. 최근 IEEE Transaction on Power System에 위상각 이동을 이용한 손실 최적화 알고리즘이 발표되었다. 동일한 손실최적화 문제를 본 논문에서는 Standard method of Lagrange Multiplier 기법을 적용하여 해석하였으며, 그 결과 저자들은 두 가지 방법이 수학적으로 동일함을 증명하였다.

전력조류방정식과 자코비안 행렬의 성질에 대하여 (Some Properties on Jacobian Matrix)

  • 이상중;양성덕
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.251-253
    • /
    • 2004
  • Though the reference angle has been specified conventionally on the slack bus, it can be specified on my bus in the system without changing power flow solutions. This paper describes that the loss sensitivity of the salk bus can be obtained through an angle reference transposition. A concept of two reference buses, consisting of "power slack bus"

  • PDF

최적유효 및 무요전력배분을 위한 신 앨고리즘 (A New Algorithm for Optimal Real and Reactive Power Dispatch)

  • Park, Young-Moon;Lee, Kwang-Yon
    • 대한전기학회논문지
    • /
    • 제32권4호
    • /
    • pp.145-154
    • /
    • 1983
  • This paper presents a new method for optimal real and reactive power dispatch for the economic operation of a power system. Unlike the usual approach of minimizing the transmission loss, this method minimizes the total production cost not only for the real power optimization problem, but also for the reactive power optimization. The control variables are real power generation of units for real power optimization, and reactive power optimization. The constraints are the operating limits on these control variables and the limits on the bus voltages. Methematical models are developed to represent the sensitivity relationships between dependent and control variables for both real and reactive power optimization modules, and thus eliminate the use of B-coefficients. In order to handle many functional inequality constraints, a modified version of the gradient projection method is developed for optimization procedure, and has shown a remarkable advantage in computation efficiency.

  • PDF

Improvement in the DNBR Modeling of RETRAN for Safety Analyses of Westinghouse Nuclear Power Plants

  • Cheong, Ae-Ju;Kim, Yo-Han
    • Nuclear Engineering and Technology
    • /
    • 제34권6호
    • /
    • pp.596-609
    • /
    • 2002
  • Korea Electric Power Research Institute has developed the in-house safety analysis methodologies for non-LOCA(Loss Of Coolant Accident) events based on codes and methodologies of vendors and Electric Power Research Institute . According to the new methodologies, analyses of system responses and calculation of DNBR(Departure from Nucleate Boiling Ratio) during the transient have been carried out with RETRAN code and a sub-channel analysis code, respectively. However, it takes too much time to calculate DNBR for each case using the two codes to search for the limiting case from sensitivity study. To simplify the search for the limiting case, accordingly, RETRAN code has been modified to roughly calculate DNBR using hot channel modeling. The W-3 correlation is already included in RETRAN as one of the auxiliary DNBR models. However, WRB-1 and WRB-2 correlations required to analyze some Westinghouse type fuels are not considered in RETRAN DNBR models. In this paper, the RETRAN DNBR models using the correlations have been developed and the partial and complete loss of forced reactor coolant flow events have been analyzed for Yonggwang units 1 and 2 with the new methodologies to validate the models. The results of the analyses have been compared with those mentioned in the chapter 15 of the Final Safety Analysis Report.

전압안정도 개선을 고려한 적정 부하차단 기법 (A study on the optimal load shedding scheme considering the voltage stability improvement)

  • 이상중;김건중;김원겸;김용배
    • 대한전기학회논문지
    • /
    • 제44권3호
    • /
    • pp.270-273
    • /
    • 1995
  • This paper proposes an optimal load shedding algorithm by which the system loss can be minimized when the load shedding is unavoidable in case of severe contingency such as the outage of key generators or lines. Shedding load .DELTA.S = .DELTA.P + J.DELTA.Q(MVA) is performed on the weakest bus (on the view of voltage stability), step by step, by the priority of the I.DELTA. = SQRT(.lambda.$\_$P/$\^$2/ + .lambda.$\_$Q/$\^$2/) index given for each load bus, where .lambda.$\_$P/ and .lambda.$\_$Q/ are the sensitivity indices representing the system loss variation versus active and reactive power change of the bus load bus. All loads are assumed to be constant power loads for convenience. A 5 bus sample system proves the effectiveness of the algorithm proposed.

정확한 상정사고 분석을 위한 민감도 행렬의 신속한 Update 기법에 관한 연구 (A Fast Sensitivity Matrix Update Technique for Accurate Contingency Analysis State Computation Technique in Power Systems)

  • 이승철;김경신;권병국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.327-329
    • /
    • 2001
  • This paper presents a fast and accurate contingency analysis in EHV systems for line outages, loss of generation of redispatching and loss-of-load or load management. Unlike other contingencies, line outage requires the modification of the Jacobian of the base case power flow and the calculation of its new inverse, which is substantially different from the original inverse. In this paper, we obtain the inverse of the new Jacobian from the original inverse without repeating the time consuming matrix inversion process. Numerical test results show the significant improvement in the accuracies compared with those obtained using the original inverse.

  • PDF