ESTABLISHMENT OF A SEVERE ACCIDENT MITIGATION STRATEGY FOR AN SBO AT WOLSONG UNIT 1 NUCLEAR POWER PLANT  

Kim, Sungmin (Korea Hydro and Nuclear Power Co., Ltd.)
Kim, Dongha (Korea Atomic Energy Research Institute)
Publication Information
Nuclear Engineering and Technology / v.45, no.4, 2013 , pp. 459-468 More about this Journal
Abstract
During a station blackout (SBO), the initiating event is a loss of Class IV and Class III power, causing the loss of the pumps, used in systems such as the primary heat transporting system (PHTS), moderator cooling, shield cooling, steam generator feed water, and re-circulating cooling water. The reference case of the SBO case does not credit any of these active heat sinks, but only relies on the passive heat sinks, particularly the initial water inventories of the PHTS, moderator, steam generator secondary side, end shields, and reactor vault. The reference analysis is followed by a series of sensitivity cases assuming certain system availabilities, in order to assess their mitigating effects. This paper also establishes the strategies to mitigate SBO accidents. Current studies and strategies use the computer code of the Integrated Severe Accident Analysis Code (ISAAC) for Wolsong plants. The analysis results demonstrate that appropriate strategies to mitigate SBO accidents are established and, in addition, the symptoms of the SBO processes are understood.
Keywords
CANDU; ISAAC; SBO; Class IV; PHTS; LOCA; ECC; RB;
Citations & Related Records
연도 인용수 순위
  • Reference
1 KAERI, ISAAC Computer Code User's Manual, KAERI/TR-3645/2008.
2 W. J. Hartmann, M. Cormier, B. Willemsen, T. Whynot, P. D. Thompson "Plant Aging Adjustments to Maintain Reactor Power at the Point Lepreau Generating Station", 5th CNS, Canada, Nov 2000.
3 ISAAC Modeling for PSA-based Severe Accidents "59RF-03500-AR-068"
4 Severe Accident Analysis for Station Blackout Scenarios using ISAAC "59RF-03500-AR-069.2"