• Title/Summary/Keyword: Power Line Interference

Search Result 201, Processing Time 0.014 seconds

Power line interference noise elimination method based on independent component analysis in wavelet domain for magnetotelluric signal

  • Cao, Xiaoling;Yan, Liangjun
    • Geosystem Engineering
    • /
    • v.21 no.5
    • /
    • pp.251-261
    • /
    • 2018
  • With the urbanization in recent years, the power line interference noise in electromagnetic signal is increasing day by day, and has gradually become an unavoidable component of noises in magnetotelluric signal detection. Therefore, a kind of power line interference noise elimination method based on independent component analysis in wavelet domain for magnetotelluric signal is put forward in this paper. The method first uses wavelet decomposition to change single-channel signal into multi-channel signal, and then takes advantage of blind source separation principle of independent component analysis to eliminate power line interference noise. There is no need to choose the layer number of wavelet decomposition and the wavelet base of wavelet decomposition according to the observed signal. On the treatment effect, it is better than the previous power line interference removal method based on independent component analysis. Through the de-noising processing to actual magnetotelluric measuring data, it is shown that this method makes both the apparent resistivity curve near 50 Hz and the phase curve near 50 Hz become smoother and steadier than before processing, i.e., it effectively eliminates the power line interference noise.

A Study on Methods of Interference Avoidance between Power Line Communications and Radio Communications (고속전력선통신과 무선통신간의 간섭 회피 방법에 대한 연구)

  • Jang, Dong-Won;Lee, Young-Hwan
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.223-226
    • /
    • 2007
  • This paper first outlines the technology used in Power Line Communications(PLC) systems, and the political support being offered to the technology, from the point of view of its effect on electromagnetic compatibility (EMC). The radio spectrum needs protection from other interferers, and there is a regime in place to provide this interference avoidance/mitigation. Nevertheless, PLC has several features that mean that it is capable of creating such interference. These features are discussed, and some published field trial results are reviewed. Difficulties in achieving compatibility between the requirements for radio protection and the requirements for operation of the PLC system mean that there is no consensus as yet as to how PLC system components can be made compliant with EMC requirements. It is concluded that there is little prospect of an accommodation between the competing demands, so that if PLC is to become widespread it will be at the expense of the radio environment.

  • PDF

Phenomenon of Power Interference and Screening Factor (전력유도 현상과 차폐계수)

  • 황종선;김영민;이경욱;김재준
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.621-624
    • /
    • 2001
  • A metal sheath provides a cable with electrostatic screening and a degree of magnetic screening. The presence of a screen on a cable also reduces the induction arising from the high-frequency components of transients caused by power-line switching and also induced transients from lightning strokes; such transient induced voltages are of increasing importance with the increasing use of miniaturized telecommunication equipment with very small thermal capacity. This paper describes electrostatic induction and electromagnetic induction caused by power interference. Also screening factors are proposed.

  • PDF

Environmental Impact on the KEPCO 765-kV Double Circuit Transmission Line (한전 765 kV 2회선 송전선로의 전기환경장애 특성)

  • Lee, D.I;Sin, K.Y;Kim, J.B
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.2
    • /
    • pp.117-126
    • /
    • 1999
  • The environmental impact of the KEPCO 765-kV transmission line was studied using a full scale test line in order to develop the design technology. Therefore this paper describes an environmental design summary of the audible noise, hum noise, wind noise, radio interference, TV interference and electric field measurement from the KEPRI 765-kV double circuit transmission test line with a bundle of $6-480mm^2$ conductors per phase. The analysis of the test results shows that 6-Rail and 6-Cardinal conductors bundle satisfy the audible noise criterion & TV interference under the stable rainy weather condition and the radio interference level under the fair weather. And the other items are also agreed with the design level criterion for KEPCO 765-kV transmission line.

  • PDF

The study of emissive electromagnetic interference DMT PLC(Power Line Communication) (DMT 방식 전력선 통신의 전자파 장애에 관한 연구)

  • Choi, Jong-Pil;Shin, Chull-Chai
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.604-608
    • /
    • 2003
  • In this paper, we studied the radiated electric field of power-line with DMT signal source in the frequency range of $1.7{\sim}30 MHz$. First, we made the midium voltage power-line communication model for PLC and calculated the current through the power-line using the impedance of the power-line model. Second, we calculated the radiated electric field in power range $-50{\sim}-30 dBm$ using the calculated current. Consequently, the calculated emissive electromagnetic field from the DMT signal is similar to the measured result. So this study is applicable to the standard regulation of electromagnetic interference for PLC.

  • PDF

Characteristics of TV Ghost Interference from Extra High Voltage Transmission Line (초고압 송전선로에 의한 TV Ghost 장해 발생 특성)

  • Ju, Mun-No;Yang, Gwang-Ho;Lee, Dong-Il;Sin, Gu-Yong
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.49 no.8
    • /
    • pp.412-417
    • /
    • 2000
  • TV ghost interference can be described as passive interference by the conducting part of transmission lines. In order to survey this interference from large-sized overhead EHV (extra high voltage) transmission line, TV reception quality was measured in the vicinity of that before and after construction. Instrumentation system was composed of ghost analyzer, TV received field intensity meter, VHF/UHF antennas, TV monitor and so on. The system is installed inside the vehicle. TV field intensity and PDUR (Perceived Desired wave to Undersired wave Ratio) are measured to evaluate TV ghost by using the system and vehicle. As the results, the useful data, which can be used to evaluate the effect of TV ghost interference from transmission lines could be obtained. In this paper, it is shown that the range of TV ghost interference from transmission lines can vary according to the frequency of TV electromagnetic wave, an incidence angle to the line and the other conditiions. At present, we are making efforts to establish a PDUR guideline for transmission lines.

  • PDF

RF Channel Characteristics of the Medium-voltage Power Line for PLC (전력선통신을 위한 중 전압용 전력선의 RF채널 특성)

  • Kim, Seon-Hyo;Kim, Gwan-Ho;Lee, Hyeong-Cheol;Sin, Cheol-Jae
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.7
    • /
    • pp.316-321
    • /
    • 2002
  • In this Paper, the channel characteristics of the medium voltage(22.9kV) power line to analysis the broadband power line communication in the frequency range up to 30MHz was measured. With the sideband electrical coupler in the operating frequency range from DC to 30MHz, we measured characteristic impedance, noise and attenuation of the medium voltage power line, and then characteristic impedance was measured at the state of unloaded medium voltage power line by Scattering parameter method of Vector Network Analyzer. As a measurement result, Channel impedance shows 100~380$\Omega$ at the less than 15MHz and 70~230$\Omega$ at the more than 15 MHz. Noise characteristics of power line shows -75dBm at 20MHz and Narrowband interference noise was from 3 MHz to 7MHz.

Limited Feedback Interference Alignment in MIMO Power Line Communication with Common-mode Reception

  • Ahiadormey, Roger Kwao;Anokye, Prince;Park, Seok-Hwan;Lee, Kyoung-Jae
    • Journal of Advanced Information Technology and Convergence
    • /
    • v.9 no.2
    • /
    • pp.1-14
    • /
    • 2019
  • This paper considers a multiple-input multiple-output (MIMO) power line communication (PLC) network where interference alignment (IA) technique is used to mitigate the interference that arises in multi-user networks. IA as a precoding technique requires perfect channel state information (CSI) to achieve maximum multiplexing gain. Due to the common-mode reception at the receiver ports, we assume imperfect CSI for the IA precoding design. Here, the CSI is quantized and sent via feedback to the transmit ports. For different levels of CSI quantization, we evaluate the performance of various IA algorithms via Monte Carlo simulations. Simulation results reveal the superior performance of the proposed scheme due to common-mode reception in IA MIMO PLC networks. It is shown that for a quantization level of 5 bits, the CM reception improves the sum-rate by up to 70%.

Power line Interference cancelling in the ECG (ECG신호에서의 전력선 간섭 제거에 관한 연구)

  • Nam, H.D.;Ahn, D.J.;Lee, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.308-310
    • /
    • 1992
  • Adaptive noise cancelling using system identification techniques for cancelling power line interference in the electrocardiogram (ECG) is presented. This method is sensitive and self-adjusting to both slow and abrupt changes in the AC interference amplitude and frequency. Computer simulation were done to compare this method with the Lekov's method.

  • PDF

Interference Cancellation Scheme of End-to-End Method in Power Line Communication System for Smart Grid (스마트 그리드 시스템을 위한 전력선 통신 시스템의 종단 간 방식의 간섭 제거 기법)

  • Seo, Sung-Il
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.2
    • /
    • pp.41-45
    • /
    • 2019
  • In this paper, we propose the interference cancellation scheme of end-to-end method algorithm for power line communication (PLC) systems in smart grid. The proposed scheme estimates the channel noise information of receiver by applying a deep learning model at the receiver. Then, the estimated channel noise is updated in database. In the modulator, the channel noise which reduces the power line communication performance is effectively removed through interference cancellation technique. As an impulsive noise model, Middleton Class A interference model was employed. The performance is evaluated in terms of bit error rate (BER). From the simulation results, it is confirmed that the proposed scheme has better BER performance compared to the theoretical model based on additive white Gaussian noise. As a result, the proposed interference cancellation with deep learning improves the signal quality of PLC systems by effectively removing the channel noise. The results of the paper can be applied to PLC for smart grid and general communication systems.