• Title/Summary/Keyword: Power Line Filter

Search Result 343, Processing Time 0.027 seconds

A Study on the Algorithm Detecting DC Line Faults (직류선로 고장 검출 알고리즘에 관한 연구)

  • Kim Chan-Ki
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.498-506
    • /
    • 2004
  • The protection algorithm of DC line grounding for the subway is proposed in this paper. Compared to the conventional protection algorithm, the proposed algorithm has a advantage that can distinguish the difference between service line and faulted line. The contents of the proposed algorithm are by using blocking filter and PLC(Power Line Carrier). Results of the simulation show that the proposed algorithm is very useful.

Design of IMT-2000 Feedforward Digital Adaptive Linear Power Amplifier (IMT-2000 전방궤환 디지털 적응 선형전력증폭기 설계)

  • Kim, Kab-Ki;Park, Gyei-Kark
    • Journal of Navigation and Port Research
    • /
    • v.26 no.3
    • /
    • pp.295-302
    • /
    • 2002
  • Currently digital communication system adapt various digital modulation schemes. All these communication systems are required to cause the minimum interference to adjacent channels, they must therefore employ the linear power amplifiers. In respect to linear power amplifiers, there are many linearization techniques. Feedforward power amplifier represent very wide bandwidth and high linearization capability. In the feedforward systems overall efficiency is reduced due to the loss of delay line. In this paper, delay filter instead of transmission delay line adapted to get more high efficiency. Experimental results showed that ACLR has improved 17.04dB which is added 2.54dB by using the delay filter.

A Study on the Design of Conducted Noise Separator for Power Line Noise (전원선 전도잡음 분리기 설계에 관한 연구)

  • 권준혁;이응주
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.4
    • /
    • pp.552-559
    • /
    • 1998
  • Conducted noise in power line contains both the common mode(CM) and differential mode(DM) noise. These two modes of noise are caused by different noise sources and paths. Therefore, CM/DM noise must be deal with individually in EMI filter. In this paper the technique to separate power line noise is presented, which can be used to measure both the CM and the DM noise from total generated noise. Also, noise-separator is designed and experimental results showed 30 dB above of separation performance in 10 kHz~10 MHz.

  • PDF

AC harmonic elimination and reactive power compensation by voltage-type active filter (전압형 능동필터에 의한 교류고조파제거와 무효전력보상)

  • 김한성;최규하;신우석;이제필
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10a
    • /
    • pp.688-692
    • /
    • 1988
  • The active filter system for harmonic current compensation is presented in this paper. The active filter, composed of a three-phase voltage-type PWM inverter and the capacitor, compensates both the harmonic currents and the reactive power by injecting the PWM current to the ac line. This paper describes the principle of harmonic current compensation, the calculation circuits for the harmonic currents to be injected, the several compensation characteristics. Also the experimental results are shown to verify the theory proposed in this paper.

  • PDF

Compact Multi-harmonic Suppression LTCC Bandpass Filter Using Parallel Short-Ended Coupled-Line Structure

  • Wang, Xu-Guang;Yun, Young;Kang, In-Ho
    • ETRI Journal
    • /
    • v.31 no.3
    • /
    • pp.254-262
    • /
    • 2009
  • This paper presents a novel simple filter design method based on a parallel short-ended coupled-line structure with capacitive loading for size reduction and ultra-broad rejection of spurious passbands. In addition, the introduction of a cross-coupling capacitor into the miniaturized coupled-line can create a transmission zero at the second harmonic frequency for better frequency selectivity and attenuation level. The aperture compensation technique is also applied to achieve a strong coupling in the coupled-line section. The influence of using the connecting transmission line to cascade two identical one-stage filters is studied for the first time. Specifically, such a two-stage bandpass filter operating at 2.3 GHz with a fractional bandwidth of 10% was designed and realized with low-temperature co-fired ceramic technology for application in base stations that need high power handling capability. It achieved attenuation in excess of -40 dB up to $4f_0$ and low insertion loss of -1.2 dB with the size of 10 mm ${\times}$ 7 mm ${\times}$ 2.2 mm. The measured and simulated results showed good agreement.

Accurate Power Sharing in Proportion for Parallel Connected Inverters by Reconstructing Inverter Output Impedance

  • Huang, Shengli;Luo, Jianguo
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1751-1759
    • /
    • 2018
  • This paper presents parallel-connected inverters to achieve accurate proportional power sharing. Due to line impedance mismatch, reactive power cannot be distributed proportionally when using the conventional $P-{\omega}$ and $\mathcal{Q}-E$ droop. In order to realize reactive proportional power sharing, the ratio of the droop coefficients should be inversely proportional to their power-sharing ratios. Meanwhile, the ratio of the line impedance should be inversely proportional to the desired power-sharing ratio, which is very difficult to be met in practice. In order to deal with this issue, a practical control strategy is presented. By measuring the PCC voltage and using the virtual impedance, the output impedance of individual inverters is reconstructed to counteract the line impedance effect. In order to guarantee system stability, a low pass filter is designed to suppress the bandwidth of the line compensation. Finally, the simulation and experimental results are given to verify the effectiveness of the proposed control strategy.

Filter Test for Partial Discharge Detection of Underground Distribution Cables (지중배전케이블의 PD 검출용 필터 시험 연구)

  • Lee, Yong-Sung;Kim, Jung-Yoon;Lee, Kwan-Woo;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.215-216
    • /
    • 2005
  • To decrease and remove of much noises that is detected in PD (partial discharge) measuring test. we forced on detection of those. We made W-LC filter for measuring PD. which adapted that to field test. We tested after design laboratory circumstances like field line. and then the phase change properties of detected signal in UHF sensor were measured by Lemke Probe and oscilloscope (TDS-3054. Tektronix). Eventually we checked decrement of noises from experimental result. Also from experimental result at the joint box of 22.9[kV] distribution line. we obtained reasonable data which enable noises to decrease. Hereafter those results will be adapted at ultra-high voltage for trouble prevention and on-line cable watch. diagnosis of those.

  • PDF

Voltage Control Strategy of new 3-phase Line-Interactive UPS System using AC Line Reactor and Parallel-Series Active Filter (AC 라인 리액터와 병렬 및 직렬 능동필터를 가지는 새로운 3상 Line-Interactive UPS 시스템의 전압제어 방식)

  • Ji, Jun-Keun;Kim, Jang-Hwan;Sul, Seung-Ki
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.3
    • /
    • pp.538-546
    • /
    • 2007
  • A new 3-phase line-interactive UPS(Uninterruptible Power Supply) system with parallel-series active power-line conditioning capability using AC line reactor and two four-leg PWM VSCs(Voltage Source Converters) was introduced recently. In this paper, the strategy of voltage control in suggested UPS system is explained. The objective of proposed voltage controllers in parallel(shunt) and series PWM VSC is to guarantee satisfactory characteristics in steady state and transient state. Therefore the experimental results to prototype UPS system having power rating of 60kVA is shown to prove the verification of voltage control strategy.

A Novel Three-Phase Four-Wire Shunt Active Filter to Eliminate Neutral Current (高調波 中性電流를 低減시키기 위한 3相4線 竝列形 能動필터에 關한 硏究)

  • 고경수;김래기;유권종;송진수;김시경
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.3
    • /
    • pp.184-190
    • /
    • 1998
  • Most buildings and factories are supplied with electric power by three-phase four-wire low voltage electric distribution system. This method pollutes the neutral line and utility sources with harmonic currents. Today, development of power conversion technology and the popularization of computer cause the neutral current to become serious. In this paper, a novel three-phase four-wire active filter is proposed to solve these harmonic problems has two purposes. The first purpose of the proposed active filiter is that the phase current has a sinusoidal waveform shape under the nonlinear load. The second purpose of the proposed active filiter is that the current on the neutral line become zero under the unbalanced power source and under the varring load conditions. The ability of the shunt active filiter has been proved to be excellent through simulations under the varring load conditions.

  • PDF

An Active Power Filter For Railway Application (전철 적용을 위한 능동필터)

  • Kim Hyeong-Jun;Song Joong-Ho
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1341-1346
    • /
    • 2004
  • Basic design for single-phase active power filter, which aims at railway applications provided with PWM-controlled converters, is comprehensively studided and its performance is presented in this paper, Active power filters are used to compensate railway signaling and public telecommunication interference due to the high-order harmonic currents generated in railway traction locomotives. A type of hybrid digital filter which is composed of low pass filter and high pass filter is proposed so that the desired harmonic reference current with accurate magnitude and phase shift can be extracted from catenary line current. A design criteria to determine input inductor L and output capacitor C is also described, considering voltage, current. PWM pattern, and switching frequency of the main converters, Finally, computer simulation and DSP-based experiments resulted from laboratory test are presented.

  • PDF