• Title/Summary/Keyword: Power Feeding Systems

Search Result 83, Processing Time 0.048 seconds

Investigation of "Unified Voltage Conditioner - UVC"

  • Antchev, Mihail;Petkova, Mariya;Gourgoulitsov, Vanjo;Antchev, Hristo
    • Journal of Power Electronics
    • /
    • v.12 no.2
    • /
    • pp.357-362
    • /
    • 2012
  • In this paper, a power electronic converter which is composed of two converters - bidirectional AC/DC converter and Series Active Power Filter (SAPF), is discussed. Structural schemas and ways of operation of control systems of converters, which are used to eliminate non sinusoidal parts of the network source voltage, are presented. At the same time, the control used stabilizes the value of the voltage feeding the load. Taking in consideration the combined functions which the device executes, it may be called Unified Voltage Conditioner - UVC.

Parameters of a guiding coil for wireless power transfer (근거리 전송에 적합한 가이딩 코일의 파라미터)

  • Woo, Dae-Woong;Kim, Jae-Hee;Lee, Dong-Hyun;Park, Kyung-Ho;Park, Wee-Sang
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.345-346
    • /
    • 2008
  • We analyzed the structural parameters of a guiding coil and a feeding loop for wireless power transfer in mid-range. The length, diameter, and number of turns of the guiding coil are the major factors to determine the resonant frequency. The separation distance between the coil and the loop also affects the power transfer ratio. This scheme has a greater transmission efficiency than using dipoles.

  • PDF

Active Frequency Drift Positive Feedback Method for Anti-islanding (단독운전검출을 위한 능동적 주파수 변화 정궤환기법)

  • So, J.H.;Jung, Y.S.;Yu, G.J.;Yu, B.G.;Lee, K.O.;Choi, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1684-1686
    • /
    • 2005
  • As photovoltaic(PV) power generation systems become more common, it will be necessary to investigate islanding detection method for PV systems. Islanding of PV systems can cause a variety of problems and must be prevented. However, if the real and reactive power of load and PV system are closely matched, islanding detection by passive methods becomes difficult. Also, most active methods lose effectiveness when there are several PV systems feeding the same island. The active frequency drift positive feedback method(AFDPF) enables islanding detection by forcing the frequency of the voltage in the island to drift up or down. In this paper the research for the minimum value of chopping fraction gain applied digital phase-locked-loop(DPLL) to AFDPF considering output power quality and islanding prevention performance are performed by simulation and experiment in IEEE Std 929-2000 islanding test.

  • PDF

PCS Power Characteristics of PV System by Fuzzy Controller (퍼지제어에 의한 PV시스템의 PCS 출력특성)

  • MOON E. A.;LIM H. W.;BAEK H. L.;CHO G. B.;OH G. K.;LIM Y. S.;KIM P. H.
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.147-150
    • /
    • 2004
  • Maximum power point tracking for PV systems traditionally uses either perturbation and observation method or incremental conductance method. Both methods require modulation of the output voltage and this leads to significant power loss. In this paper, a method, which senses output circuit voltage and short circuit current and use the above two parameters for optimum control with a fuzzy controller, is introduced. The short circuit current of PV cell represents illumination, and the output circuit voltage carry on information about the temperature. PCS(power conditioning system) is controlled not only feed to inverter for stability voltage variation despite of variety external environment, but also operate in order to feeding voltage and current at maximum power point by boost type chopper.

  • PDF

Performance Analysis of Shell Coal Gasification Combined Cycle systems (Shell 석탄가스화 복합발전 시스템의 성능해석 연구)

  • Kim, Jong-Jin;Park, Moung-Ho;Song, Kyu-So;Cho, Sang-Ki;Seo, Seok-Bin;Kim, Chong-Young
    • Journal of Energy Engineering
    • /
    • v.6 no.1
    • /
    • pp.104-113
    • /
    • 1997
  • This study aims to develop an analysis model using a commercial process simulator-ASPEN PLUS for an IGCC (Integrated Gasification Combined Cycle) system consisting a dry coal feeding, oxygen-blown entrained gasification process by Shell, a low temperature gas clean up process, a General Electric MS7001FA gas turbine, a three pressure, natural recirculation heat recovery steam generator, a regenerative, condensing steam turbine and a cryogenic air separation unit. The comparison between those results of this study and reference one done by other engineer at design conditions shows consistency which means the soundness of this model. The greater moisture contents in Illinois#6 coal causes decreasing gasifier temperature and the greater ash and sulfur content hurt system efficiency due to increased heat loss. As the results of sensitivity analysis using developed model for the parameters of gasifier operating pressure, steam/coal ratio and oxygen/coal ratio, the gasifier temperature increases while combustible gases (CO+H2) decreases throughout the pressure going up. In the steam/coal ratio analysis, when the feeding steam increases the maximum combustible gas generation point moves to lower oxygen/coal ratio feeding condition. Finally, for the oxygen/coal ratio analysis, it shows oxygen/coal ratio 0.77 as a optimum operating condition at steam/coal feeding ratio 0.2.

  • PDF

Pattern Recognition of Monitored Waveforms from Power Supplies Feeding High-Speed Rail Systems

  • Gu, Wei;Zhang, Shuai;Yuan, Xiaodong;Chen, Bing;Bai, Jingjing
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.1
    • /
    • pp.55-64
    • /
    • 2016
  • The development of high-speed rail (HSR) has had a major impact on the power supply grid. Based on the monitored waveforms of HSR, a pattern recognition approach is proposed for the first time in this paper to identify the operating conditions. To reduce the data dimensions for monitored waveforms, the principal component analysis (PCA) algorithm was used to extract the characteristics and their waveforms from the monitored waveforms data. The dynamic time wrapping (DTW) algorithm was then used to identify the operating conditions of the HSR. Cases studies show that the proposed approach is effective and feasible, and that it is possible to identify the real-time operating conditions based on the monitored waveforms.

A Study on DC Power Regeneration for Railway using Parallel PWM Converter (병렬 PWM 컨버터를 이용한 철도차량 직류 전력 회생장치에 관한 연구)

  • Lee Jong-Moo;Jang Su-jin;Song Sang-Hun;Won Chung-Yuen;Ahn Kyu-Bok;Lee Joon-Gee
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.524-527
    • /
    • 2004
  • When the electric tractions are stopped or driven through the falling slope way, it occured to surplus energy in the DC power line. At present, these energy are exhausted by breaking-system. The converter is not only capable of feeding energy back into the AC source during excessive regeneration. It is issued for this surplus energy regenerating system. These systems are faced with high voltage and high power for railway DC power regeneration. This paper proposed a parallel PWM converter how to solve these problem.

  • PDF

An Effective Rotor Current Controller for Unbalanced Stand-Alone DFIG Systems in the Rotor Reference Frame

  • Phan, Van-Tung;Lee, Hong-Hee;Chu, Tae-Won
    • Journal of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.724-732
    • /
    • 2010
  • This paper presents an effective rotor current controller for variable-speed stand-alone doubly fed induction generator (DFIG) systems feeding an unbalanced three-phase load. The proposed current controller is developed based on proportional plus two resonant regulators, which are tuned at the positive and negative slip frequencies and implemented in the rotor reference frame without decomposing the positive and negative sequence components of the measured rotor current. In addition, the behavior of the proposed controller is examined in terms of control performance and stability with respect to rotor speed variations, i.e., slip frequency variations. Simulations and experimental results are shown to validate the robustness and effectiveness of the proposed control method.

Active Frequency Drift Positive Feedback Method for Anti-islanding using Digital Phase-Locked-Loop (디지털 위상검출기법을 적용한 능동적 주파수 변화 정궤환기법)

  • Lee, Ki-Ok;Young, Young-Seok;Choi, Ju-Yeop;Choy, Ick;Song, Seung-Ho;Ko, Moon-Ju
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.2
    • /
    • pp.37-44
    • /
    • 2007
  • As photovoltaic(PV) power generation system becomes more common, it will be necessary to investigate islanding detection method for PV systems. Islanding of PV systems can cause a variety of problems and must be prevented. However, if the real and reactive power of the load and PV system are closely matched, islanding detection by Passive methods becomes difficult. Also, most active methods lose effectiveness when there are several PV systems feeding the same island. The active frequency drift positive feedback method(AFDPF) enables islanding detection by forcing the frequency of the voltage in the island to drift up or down. In this paper the research for the minimum value of chopping fraction gain applied digital phase-locked-loop (DPLL) to AFDPF considering output power quality and islanding prevention performance are performed by simulation and experiment according to IEEE Std 929-2000 islanding test.

A New Three Winding Coupled Inductor-Assisted High Frequency Boost Chopper Type DC-DC Power Converter with a High Voltage Conversion Ratio

  • Ahmed Tarek;Nagai Shinichiro;Hiraki Eiji;Nakaoka Mutsuo
    • Journal of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.99-103
    • /
    • 2005
  • In this paper, a novel circuit topology of a three-winding coupling inductor-assisting a high-frequency PWM boost chopper type DC-DC power converter with a high boost voltage conversion ratio and low switch voltage stress is proposed for the new energy interfaced DC power conditioner in solar photovoltaic and fuel cell generation systems. The operating principle in a steady state is described by using its equivalent circuits under the practical condition of energy processing of a lossless capacitive snubber. The newly-proposed power MOSFET boost chopper type DC-DC power converter with the three-winding coupled inductor type transformer and a single lossless capacitor snubber is built and tested for an output power of 500W. Utilizing the lower voltage and internal resistance power MOSFET switch in the proposed PWM boost chopper type DC-DC power converter can reduce the conduction losses of the active power switch compared to the conventional model. Therefore, the total actual power conversion efficiency under a condition of the nominal rated output power is estimated to be 81.1 %, which is 3.7% higher than the conventional PWM boost chopper DC power conversion circuit topology.