• Title/Summary/Keyword: Power Factor Control

Search Result 1,431, Processing Time 0.029 seconds

Switched discrete sliding mode control for ZCS series rosonant AC to DC converter (영전류 스위칭 방식의 직렬 공진형 AC/DC 컨버터를 위한 전환모드 이산 슬라이딩 제어)

  • 문건우;이정훈;이대식;윤명중
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1993.10a
    • /
    • pp.1219-1226
    • /
    • 1993
  • A buck-boost zero current switched(ZCS) series resonant AC to DC converter for the DC output voltage regulation together with high power factor is proposed. The proposed single phase AC to DC converter enables a zero current switching operation of all the power devices allowing the circuit to operate at high swtiching frequencies and high power levels. A dynamic model for this Ac to DC converter is developed and an analysis for the internal operational characteristics is explored. Based on this analysis, a switched discrete sliding mode control(SDSMC) technique is investigated and its advantages over the other types of current control techniques are discussed. With the proposed control technique, the unity power factor without a current overshoot and a wide range of output voltage can be obtained.

  • PDF

Set up a Demand Factor of EV Chargers and Its Control Method in Apartments (공동주택에서의 전기자동차 충전기 수용률 설정과 그 제어방법)

  • Kim, Myeong-Soo;Hong, Soon-Chan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.8
    • /
    • pp.98-105
    • /
    • 2014
  • In this paper, we have analyzed the power consumption property of EVs(Electric Vehicles) chargers established in a public place, proposed reasonable demand factors by the number of established EV chargers and its control method in apartments. The optimization of power system and the suppression of the peak load can be controlled through the proposed demand factors and charging scheduling control algorithm. In this paper, electrical design and an case analysis were carried out on a sample apartment complex to prove the effectiveness of the power system. As a result, emergency power transformer capacity has been reduced by approximately 25%, and we have confirmed that the electric rates saving and the control of peak load value is possible.

A Study on the Characteristics of Control Schemes for STATCON (STATCON 제어방식에 따른 특성 연구)

  • Han, Y.S.;Cha, J.D.;Hong, S.W.;Lee, H.S.;Moon, K.W.;Yoon, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2076-2078
    • /
    • 1998
  • This paper presents STATCON(Static Condenser) control schemes for voltage regulation, power factor correction and harmonics mitigation. Each control scheme can be applied in the system depending on the system requirements. The 20KVA STATCON is developed and tested in the reduced system model for the verification of three different control algorithms. The results of proposed controls are compared for power factor correction and voltage regulation algorithms. For each algorithm, harmonic mitigation scheme is adopted as a part of control. Finally verification of STATCON for the transient response is implemented by voltage flicker test.

  • PDF

Direct Power Sensorless Control of Three-Phase AC/DC PFC PWM Converter using Virtual Flux Observer (가상 자속관측기를 이용한 3상 AC/DC PFC PWM 컨버터의 직접 전력 센서리스 제어)

  • Kim, Young-Sam;Kwon, Young-Ahn
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.10
    • /
    • pp.1442-1447
    • /
    • 2012
  • In this paper, direct power control system for three-phase PWM AC/DC converter without the source voltage sensors is proposed. The sinusoidal input current and unity effective power factor are realised based on the estimated flux in the observer. Both active and reactive power calculated using estimated flux. The estimation of flux is performed based on the Reduced-order flux observer using the actual currents and the command control voltage. The source voltage sensors are replaced by a flux estimator. The active and reactive powers estimation are performed based on the estimated flux and Phase anble. The proposed algorithm is verified through simulation and experiment.

Cooling System for Power Transformer Using Weighting Function (하중함수를 이용한 전력용 변압기 냉각 시스템)

  • Cho, Do-Hyeoun
    • 전자공학회논문지 IE
    • /
    • v.49 no.2
    • /
    • pp.40-45
    • /
    • 2012
  • In this paper, cooling system of power transformers is proposed for temperature optimized control. We predict the peak temperature of power transformer coils using load factors and construct a cooling system using weighting function. For the optimized temperature control for power transformer, a correlation function based on the load factor of a load current and the each temperatures for winding coils, for air and for oil is presented to predict the winding-coil peak temperature. Also, the results controlled by applying the power transformer is presented.

A Study on Optimal Selection of Inductance for Power Factor Improvement of Buck AC/DC LED Driver With Wide Input Voltage Range (입력 전압 범위가 넓은 벅 AC/DC LED 구동기의 역률 개선을 위한 최적 인덕턴스 선택에 관한 연구)

  • Kim, Marn-Go
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.4
    • /
    • pp.302-305
    • /
    • 2021
  • Selection of the optimal inductance for power factor improvement of a buck AC/DC light-emitting diode (LED) driver with wide input voltage range is described in this study. The power factor change based on the slope compensation is obtained for various normalized output current (NOC) values using discrete-time domain analysis. The possibility of implementing constant slope compensation is described using power factor curves for various NOC values. NOC = 0.5 is chosen for the value of inductance with consideration for the simple implementation and reduction of inductor size. Experimental results of the inductance corresponding to NOC = 0.5 are presented.

Unified Active Power Filter Compensating For Source Voltage Unbalance/Current Harmonics and Power Factor Simultaneously (전원 전압의 불평형과 고조파 전류 및 역률을 동시에 보상하는 통합형 능동 전력필터)

  • Lee, Jong-Kun;Seok, Jul-Ki;Lee, Dong-Choon
    • Proceedings of the KIEE Conference
    • /
    • 2004.04a
    • /
    • pp.103-105
    • /
    • 2004
  • In this paper, a novel control scheme compensating for source voltage unbalance and current harmonics and power factor simultaneously in unified active power filter systems combined with shunt passive filters is proposed, where no low/high-pass filter are used in deriving the reference voltage for compensation. Using digital all-pass filters, the phase angle and the reference voltages compensating for harmonic current and unbalanced voltage are derived from the positive sequence component of the unbalanced voltage. The amplitude of d-axis current in a series filter is controlled as zero for power factor correction. The validity of the proposed control scheme has been verified by experimental results.

  • PDF

A New Unity Power Factor Rectifier System using an Active Waveshaping Technique

  • Choi, Se-Wan;Bae, Young-Sang
    • Journal of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.173-179
    • /
    • 2009
  • This paper proposes a new three-phase diode rectifier system with a sinusoidal input current at unity power factor and a regulated and isolated output voltage at low level. The inherent natural wave-shaping capability of the reduced kVA polyphase transformer together with an active current wave-shaping technique results in a significant reduction of input and output filter requirements associated with switching ripple and EMI. The operation principles are described along with a design example and a comparative evaluation. Experimental results on a 1.5kW prototype are provided to validate the proposed concept.

Nonlinear Representation of Two-Stage Power-Factor-Correction AC/DC Circuits

  • Orabi Mohamed;Ninomiya Tamotsu
    • Journal of Power Electronics
    • /
    • v.4 no.4
    • /
    • pp.197-204
    • /
    • 2004
  • Two-stage Power-Factor-Correction (PFC) converters are the most common circuits for drawing sinusoidal and in phase current waveforms from an ac source with a good regulated output voltage. The first stage is a boost PFC converter with average-current-mode control for achieving the near-unity power factor and the second stage is a forward converter with voltage-mode control to regulate the output voltage. Stability analysis and design methods of two-stage PFC converters have previously been discussed using linear models. Recently, new nonlinear phenomena have been detected in pre-regulator boost PFC circuits and a new nonlinear model has been proposed for pre-regulated PFC converters. Therefore, investigation of two-stage PFC converters from the nonlinear viewpoint becomes important because the second stage DC/DC converter adds more complexity to the circuit. So, this paper introduces a study of the stability of two-stage PFC converters. A novel nonlinear model of two-stage PFC converters is proposed. Then, a stability analysis is made based upon this nonlinear model. The high correspondence between the simulated and experimental results confirms our analysis.

Single Stage PFC Flyback Converter Using Top Switch (Top 스위치를 이용한 단일 전력단 역률개선 플라이백 컨버터)

  • Lim Chang Seob;Kwon Soon Kurl;Lee Hyun Woo;Kim Eun Soo
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.669-672
    • /
    • 2001
  • Generally, previous converter is divided into two categories to get high power factor and good output regulation. These two categories can be combined a category with a main switch. These converter is called Single Stage PFC Converter. This approach has good electrical characteristics of high power factor and fast output voltage regulation. The cost and size are important factor to design the converter in low power system. Even single stage can reduce the size and cost, but this approach needs to have additional circuit like control, PWM circuit. To improve these demerits, Top switch is one of good choice In reduce and size in low power single stage converter. Because it has the ability of current limit, thermal protection, oscillator, control circuit as well as a main switch ability.

  • PDF