• 제목/요약/키워드: Power Factor

검색결과 6,145건 처리시간 0.029초

역률개선 위한 자기에어지 궤환기법의 간단한 삼상 단일전력단 AC/DC 컨버터 (A Simple Three-Phase Single-Stage AC/DC Converter with Magnetic Energy Feedback Technique for Power Factor Correction)

  • 문건우;윤석호;윤종수;이기선;추진부
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.438-443
    • /
    • 1998
  • A simple single-stage AC/DC forward converter with transformer magnetic energy feedback technique for power factor correction is proposed. The operational principle of the proposed converter is presented. The proposed converter gives the good power factor correction, low line current harmonic distortions, and tight output voltage regulation. The prototype shows high power factor with low line current harmonics.

  • PDF

3상 AC/DC 스위치 모드 승압형 컨버터를 이용한 CO2 아크 용접기 역률개선에 관한 연구 (A Study on Power Factor Correction of CO2 Arc Welder Using Three Phase Switch Mode Converter)

  • 이정훈;김재문;안정준;이상석;원충연;김세찬
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.149-153
    • /
    • 1998
  • In this paper A switched mode AC/DC three phase boost converter with high power factor and sinusoidal input current waveform is analyzed and simulated. The proposed converter retain high power factor and sinusoidal input current waveform even under electric arc welder load. It is shown that experimental result and simulation waveform yield a sinusoidal input current waveform at high power factor.

  • PDF

결합 인덕터 및 에너지 회생 회로를 사용한 새로운 고 효율 ZVS AC-DC 승압 컨버터 (New High Efficiency Zero-Voltage-Switching AC-DC Boost Converter Using Coupled Inductor and Energy Recovery Circuit)

  • 박경수;김윤호
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제50권10호
    • /
    • pp.501-507
    • /
    • 2001
  • In this paper, new high-efficiency zero voltage switching (ZVS) AC-DC boost converter is proposed to achieve power factor correction by simplifing energy recovery circuit. A lot of high power factor correction circuits have been proposed and applied to increase input power factor and efficiency. Most of these circuits may obtain unity power factor and achieve sinusoidal current waveform with zero voltage or/and zero current switching. However, it is difficult for them to obtain low cost, small size, low weight, and low noise. The topology proposed to improve these problems can compact the devices in circuit and can achieve high efficiency ZVS AC-DC boost converter. Simulation and experimental results show that this topology is capable of obtaining high power factor and increasing the efficiency of the system.

  • PDF

파형개선을 위한 방전등 안정기 개발 (Development of discharge lamp ballast for wave improvement)

  • 이오걸;송달섭;김태우;이준탁;송호신;김종기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.85-88
    • /
    • 2000
  • This paper was development a discharge lamp ballast in order to wave improvement of high power factor and high efficiency. The discharge lamp ballast consists of a power factor correction circuit and a correction circuit on switching frequency of inverter. Instead of passive power factor circuit, active power factor circuit is adopted. Because it has the advantage of size, weight, total harmonic distortion, out DC voltage regulation, and power factor. The power factor circuit with MG34262 is controlled by variable frequency discontinuous mode. Results experiments, discharge lamp ballast is showed to have excellent for the proposed electronic ballast's operation and characteristics.

  • PDF

부하변동에 속응하는 역률개선형 전력절감시스템 (Electric energy saving system with high speed response to load variation using power-factor correction)

  • 김태수;강형식;주경돈;류승헌;구경완;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2388-2390
    • /
    • 2002
  • Small type electric energy saving system is proposed in this paper. The system improves power factor fastly according to load variation of each customer. Phases of voltage and current are detected as 1[ms] unit. Phase coincident algorithm is applied for power factor improvement. Capacitance is controlled for optimal power factor correction. Series reactor is controlled for harmonics reduction. Non-contact device is used for fast response and long life. Test result shows the effect of this system. Power factor of 40[W] electric fan is improved from 95[%] to 100[%]. In the case of electric light, power factor is improved from 82[%] to 100[%]. Response time for load variation is less than 1[ms].

  • PDF

Estimation of the Nuclear Power Peaking Factor Using In-core Sensor Signals

  • Na, Man-Gyun;Jung, Dong-Won;Shin, Sun-Ho;Lee, Ki-Bog;Lee, Yoon-Joon
    • Nuclear Engineering and Technology
    • /
    • 제36권5호
    • /
    • pp.420-429
    • /
    • 2004
  • The local power density should be estimated accurately to prevent fuel rod melting. The local power density at the hottest part of a hot fuel rod, which is described by the power peaking factor, is more important information than the local power density at any other position in a reactor core. Therefore, in this work, the power peaking factor, which is defined as the highest local power density to the average power density in a reactor core, is estimated by fuzzy neural networks using numerous measured signals of the reactor coolant system. The fuzzy neural networks are trained using a training data set and are verified with another test data set. They are then applied to the first fuel cycle of Yonggwang nuclear power plant unit 3. The estimation accuracy of the power peaking factor is 0.45% based on the relative $2_{\sigma}$ error by using the fuzzy neural networks without the in-core neutron flux sensors signals input. A value of 0.23% is obtained with the in-core neutron flux sensors signals, which is sufficiently accurate for use in local power density monitoring.

발전소 소내전력 고조파 및 역률 개선용 SVC 개발에 관한 연구 (A Study on Development of SVC to Improve Harmonics and Power Factor of Power Plant)

  • 윤광희;이희진
    • 전기학회논문지
    • /
    • 제60권11호
    • /
    • pp.2109-2118
    • /
    • 2011
  • The power system has to maintain its synchronism from transient disturbances and oscillations. To achieve this, the static var compensator(SVC), which is a flexible AC transmission system(FACTS), is applied to the power system. SVC using an advanced control algorithm improves the stability of power system. This paper is a study on design of SVC to improve harmonics and power factor of power plant. The proposed SVC analyzes harmonics, voltage drop and reactive power in real time. On the basis of the analysis of the data, the SVC using a switching control algorithm decreases harmonic signals and increases the power factor. The experimental results show that the proposed SVC enhances the stability of power system.

외식기업의 경쟁력 강화 요인에 관한 연구 - 외식기업 내부요인을 중심으로 - (Research about Competitive Power High Position of Food-Service Industry - Laying Stress on Eating Out Company Interior Factor -)

  • 유택용;박면애
    • 한국조리학회지
    • /
    • 제10권3호
    • /
    • pp.83-96
    • /
    • 2004
  • According to construction of global administration environment, all over the world was ended up in infinite competition period. Because eating out company also competes with another company, it must enjoy competitive power high position to secure high position continuously, classified by formation constituent's individuation and two aspects of organic special quality by the factor. Individuation classified by formation constituent's business ability, personal relations, age factors of Information Technology, and organic special quality classifies by factor of formation culture and result that analyze eating out company's business condition competitive power reinforcement effect factor is same as following. First, was construed by company culture, personal relations, business ability period of ten days with family Restaurant, and Information Technology showed that do not influence. Competitive power reinforcement effect factor with special restaurant was construed by company culture, personal relations, business ability period of ten days, and fast food company culture and Information Technology factor with hotel restaurant company culture by competitive power reinforcement effect factor construe.

  • PDF

부스트-플라이백 결합형 ZCS Quasi-Resonant 역률개선 컨버터 (Integrated Boost-Flyback ZCS Quasi-Resonant Power Factor Preregulator)

  • 이준영;문건우;김현수;윤명중
    • 전력전자학회논문지
    • /
    • 제4권1호
    • /
    • pp.91-98
    • /
    • 1999
  • 본 논문에서는 역률개선용 단일 스위치 부스트 플라이백 결합형 ZCS quasi-resonant converter(QRC)를 제안한다. 제안된 컨버터는 입력전류를 불연속 모드로 동작시켜 역률을 개선하며 입력전류의 zero-crossing-point에서의 왜곡을 개선함으로써 고조파를 감소시켜 역률을 향상시켰으며 좋은 출력전압의 regulation 성능을 가지고 있다. 그리고 체계적인 설계를 위하여 설계식을 제안하였으며 제안된 설계식을 통하여 프로토타입 컨버터를 설계하였다. 실험결과 효율은 약 86%, 역률은 약 0.985이상을 얻었다. 따라서 본 컨버터는 스위칭 주파수가 수백 kHz이상이고 높은 regulation성능을 요구하는 낮은 전압의 소용량 컨버터에 적합하다.

  • PDF

한국의 지능형 전력동시부하율 저감시스템에 관한 연구 (A Study on Simultaneous Load Factor of Intelligent Electric Power Reduction System in Korea)

  • 김태성;이종환
    • 산업경영시스템학회지
    • /
    • 제35권1호
    • /
    • pp.24-31
    • /
    • 2012
  • This study is designed to predict the overall electric power load, to apply the method of time sharing and to reduce simultaneous load factor of electric power when authorized by user entering demand plans and using schedules into the user's interface for a certain period of time. This is about smart grid, which reduces electric power load through simultaneous load factor of electric power reduction system supervision agent. Also, this study has the following characteristics. First, it is the user interface which enables authorized users to enter and send/receive such data as demand plan and using schedule for a certain period of time. Second, it is the database server, which collects, classifies, analyzes, saves and manages demand forecast data for a certain period of time. Third, is the simultaneous load factor of electric power control agent, which controls usage of electric power by getting control signal, which is intended to reduce the simultaneous load factor of electric power by the use of the time sharing control system, form the user interface, which also integrate and compare the data which were gained from the interface and the demand forecast data of the certain period of time.