• Title/Summary/Keyword: Power Facility

Search Result 1,286, Processing Time 0.027 seconds

A study on the development of management system in electric culvert (지하전력구 감시제어시스템 개발연구)

  • 우희곤;이범석;이복규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.90-95
    • /
    • 1990
  • The long distance electric culvert employing power cable is using and increasing to improve reliability and Capacity of power supply in KEPCO. The purpose of this study in development of management system which used to security, maintenance, operation, and facility protection efficiently in electric culvert.

  • PDF

Power Demand Estimation of Consuming Facility using Orthogonal Polynomial Regression Model (직교 다항 회귀모델을 이용한 수용설비의 소비전력 추정)

  • 고희석;이충식;지봉호;김일중
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.75-81
    • /
    • 1999
  • This paper presents in the rrethod power demand estimated of consuming facility algorithm using orthogonal polynomial regression rmdel. Estimation rmdel presented can use mathematical rrethod consists. of extrapolation and correlation rrethod, Computation tirre and capacity of presented rmdel was rmre economic than multiple regression rrodel because low-order equation can use in the high-order equation without sorre correction, and vice-versa. Therefore this rmthed can be very usefulness rmthed in the power demand estimation Fourth-order rrodel was very good armng this rrodel that was coJTJp)Sed the estimation rmdel of second, third and fourth-order. Power demand estimated result of consuming facility using correlation rrethod was good in the percentage error of about 2[%1 Also It was to verify efficiency and awroPJiation the estimated rmdel that estimation percentage error was about 1[%] in the oower demand estimated result of 1997.

  • PDF

Development of a Computer Program for the Analysis Logistics of PWR Spent Fuels (PWR 사용후핵연료 운반 물량 분석 프로그램 개발)

  • Choi, Heui-Joo;Cha, Jeong-Hun;Choi, Jong-Won
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.2
    • /
    • pp.147-154
    • /
    • 2008
  • It is expected that the temporary storage facilities at the nuclear power plants will be full of the spent fuels within 10 years. Provided that a centralized interim storage facility is constructed along the coast of the Korean peninsula to solve this problem, a substantial amount of spent fuels should be transported by sea or by land every year. In this paper we developed a computer program for the analysis of transportation logistics of the spent fuels from 4 different nuclear power plant sites to the hypothetical centralized interim storage facility and the final repository. Mass balance equations were used to analyze the logistics between the nuclear power plants and the interim storage facility. To this end a computer program, CASK, was developed by using the VISUAL BASIC language. The annual transportation rates of spent fuels from the four nuclear power plant sites were determined by using the CASK program. The parameter study with the program illustrated the easiness of logistics analysis. The program could be used for the cost analysis of the spent fuel transportation as well.

  • PDF

An Experimental Study on Applying Heat Pump System to Facility Horticulture House (히트펌프 시스템의 시설원예 적용에 관한 실험적 연구)

  • Kim, Jae-Dol
    • Journal of Power System Engineering
    • /
    • v.17 no.6
    • /
    • pp.88-94
    • /
    • 2013
  • As the results of analysis that are applying a heat pump using underground water as heat source of facility horticulture house, temperature change in house, growth of cultivated plants and the crop characteristic, the conclusion can be acquired as follows. It was possible to maintain the chamber temperature through operating heat pump with setting goal temperature at $16^{\circ}C$ and temperature variation at ${\pm}3^{\circ}C$. And cooling and heating coefficient of performance in heat pump system are different from setting room temperature and operation condition of equipment, totally in case that the setting temperature in house is low, the coefficient of performance and the in case that temperature departure is low. In case that the house does not heated, the result of the growth characteristic of cucumber planted last 50days is that cucumber grown in house equipped with heat pump is the most favorable growth characteristic due to maintaining a constant room temperature. After 90 days, the quantity and weight cucumber harvested in each house are averagely 9.8%, 13.1% increase and more heavy weight respectively. So it is researched that crop characteristic is superior.

WOLSONG LOW- AND INTERMEDIATE-LEVEL RADIOACTIVE WASTE DISPOSAL CENTER: PROGRESS AND CHALLENGES

  • Park, Jin-Beak;Jung, Hae-Ryong;Lee, Eun-Young;Kim, Chang-Lak;Kim, Geon-Young;Kim, Kyung-Su;Koh, Yong-Kwon;Park, Kyung-Woo;Cheong, Jae-Hak;Jeong, Chan-Woo;Choi, Jong-Soo;Kim, Kyung-Deok
    • Nuclear Engineering and Technology
    • /
    • v.41 no.4
    • /
    • pp.477-492
    • /
    • 2009
  • In this paper, we discuss the experiences during the preparation of the Wolsong Low- and Intermediate-Level Radioactive Waste Disposal Center. These experiences have importance as a first implementation for the national LILW disposal facility in the Republic of Korea. As for the progress, it relates to the area of selected disposal site, the disposal site characteristics, waste characteristics of the disposal facility, safety assessment, and licensing process. During these experiences, we also discuss the necessity for new organization and change for a radioactive waste management system. Further effort for the safe management of radioactive waste needs to be pursued.

Development of a prediction model relating the two-phase pressure drop in a moisture separator using an air/water test facility

  • Kim, Kihwan;Lee, Jae bong;Kim, Woo-Shik;Choi, Hae-seob;Kim, Jong-In
    • Nuclear Engineering and Technology
    • /
    • v.53 no.12
    • /
    • pp.3892-3901
    • /
    • 2021
  • The pressure drop of a moisture separator in a steam generator is the important design parameter to ensure the successful performance of a nuclear power plant. The moisture separators have a wide range of operating conditions based on the arrangement of them. The prediction of the pressure drop in a moisture separator is challenging due to the complexity of the multi-dimensional two-phase vortex flow. In this study, the moisture separator test facility using the air/water two-phase flow was used to predict the pressure drop of a moisture separator in a Korean OPR-1000 reactor. The prototypical steam/water two-phase flow conditions in a steam generator were simulated as air/water two-phase flow conditions by preserving the centrifugal force and vapor quality. A series of experiments were carried out to investigate the effect of hydraulic characteristics such as the quality and liquid mass flux on the two-phase pressure drop. A new prediction model based on the scaling law was suggested and validated experimentally using the full and half scale of separators. The suggested prediction model showed good agreement with the steam/water experimental results, and it can be extended to predict the steam/water two-phase pressure drop for moisture separators.

Evaluation of Collection Efficiency of Electrostatic Precipitator for Removing Limestone Slurry Particles (석회석 슬러리 입자 제거를 위한 전기집진기 포집효율 평가)

  • Lee, Gi-Hyuk;Kim, Moon-Won;Yu, Tae-U;Yook, Se-Jin
    • Particle and aerosol research
    • /
    • v.15 no.2
    • /
    • pp.57-65
    • /
    • 2019
  • Recently, there has been much research on the effect of fine dust on human body with increasing interest in the fine dust. Thermal power plant, which is considered as one of the main sources of fine dust, is reported to be responsible for 14% of the total amount of domestic fine dust in the Republic of Korea. Therefore, dust collecting devices in the thermal power plant need to be improved. In this study, the electrostatic precipitator (ESP) was considered to substitute for a mist eliminator used in flue gas desulfurization facility. By considering real situation in the flue gas desulfurization facility, the collection efficiency of the ESP was evaluated by using the sprayed limestone slurry particles. The collection efficiency of the ESP was higher than that of the mist eliminator, showing the possibility of replacing the mist eliminator with the ESP in flue gas desulfurization facility.

Electrical Power System Studies for an Industrial Cogeneration Power Plant (자가발전설비가 있는 산업플랜트의 전력계통 응동 해석)

  • Yun, Jae-Hun;Lim, Seong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1215-1217
    • /
    • 1999
  • Electrical studies are required to assure the proper integration of cogeneration facility into a industrial plant electrical system and the connected utility grid. Details of such study efforts are presented, including boundary limit for the system modeling, short-circuit and load flow studies, stability studies, load shedding studies, and harmonics studies.

  • PDF