• Title/Summary/Keyword: Power Equipment Diagnosis

Search Result 182, Processing Time 0.027 seconds

Case Study of Intermittent Engine Hesitation Fault Diagnosis By CKPS Fault (LPI차량에서 CKPS불량으로 주행 중 간헐적인 엔진부조 현상의 고장진단)

  • Kim, Sung Mo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.6
    • /
    • pp.624-629
    • /
    • 2014
  • The purpose of this study is to carry out the task of engine hesitation which occurred intermittently in driving due to the defective CKPS of LPI vehicles. As the result of the wrong data from the equipment of D-logger, the signal error of CKPS caused the engine hesitation. We performed a study in the followings to analyze and investigate the cause effectively. First, we have investigated the control wiring harness and connector pin contact defect inspection. Second, we have inspected the defection of CKPS separately. From this study, it was found that the engine hesitation were caused by the bad durability and we have showed how to diagnosis the fault of the engine hesitation intermittently while driving. Therefore, it is determined that we have to improve the durability of the CKPS through a strict quality control and to increase the reliability.

A Study on Fault Diagnosis Algorithm for Rotary Machine using Data Mining Method and Empirical Mode Decomposition (데이터 마이닝 기법 및 경험적 모드 분해법을 이용한 회전체 이상 진단 알고리즘 개발에 관한 연구)

  • Yun, Sang-hwan;Park, Byeong-hui;Lee, Changwoo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.4
    • /
    • pp.23-29
    • /
    • 2016
  • Rotary machine is major equipment in industry. The rotary machine is applied for a machine tool, ship, vehicle, power plant, and so on. But a spindle fault increase product's expense and decrease quality of a workpiece in machine tool. A turbine in power plant is directly connected to human safety. National crisis could be happened by stopping of rotary machine in nuclear plant. Therefore, it is very important to know rotary machine condition in industry field. This study mentioned fault diagnosis algorithm with statistical parameter and empirical mode decomposition. Vibration locations can be found by analyze kurtosis of data from triaxial axis. Support vector of data determine threshold using hyperplane with fault location. Empirical mode decomposition is used to find fault caused by intrinsic mode. This paper suggested algorithm to find direction and causes from generated fault.

A Study on Variation of Counterplan in Harmonics Interference Equipment (고초파 장해기기의 저감 대책의 변화에 관한 연구)

  • 성은하;오무송;이은학;김태성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.414-417
    • /
    • 1999
  • According to development of power electric technology from industrial field to electronic home appliances, recent SMPS using semiconductor is spread widely. Electric converting instrument uses a sine wave voltage source, namely an usual power source, and it gets a non-sines power source from power source because current flows through one part in waveform of one cycle. This injects higher harmonic source in source part, absorb pollution source. And this cause quality deterioration, durability shortage of electric power instrument, spreading accident of electric solver system, and so on. It can't supply an electric source of good quality in industry, so become an impedimental element in improving productivity and reliance. This study can be used in prediction of hindrance and diagnosis material and intends to suggest a countermeasure about measurement data.

  • PDF

Portable Equipment for Partial Discharge Diagnosis of On-site 22.9 kV XLPE Cable (실선로 22.9kV XLPE 케이블 진단을 위한 포터블 부분방전 진단장치)

  • Lee, Yong-Sung;Kim, Jung-Yoon;Lee, Hyun-Sun;Jung, Sung-Man;Lee, Chang-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1449-1452
    • /
    • 2007
  • 배전 케이블 부분방전 측정에서는 외부노이즈, 코로나가 동반되어 검출되고 있다. 특히, 단말부의 부분방전측정에서는 부분방전 현상이 크게 발생하여 측정될 경우 다른 상에서도 유입되어 검출되는데 코로나나 외부의 노이즈가 크게 유입될 경우 진단의 어려움이 있다. 더불어 각 상의 위상을 직접검출이 어려운 송배전 케이블의 단말에서는 유기된 신호의 상을 찾는데도 어려움을 주고 있다. 이러한 문제를 반영하여 현장 측정이 용의하도록 이동형 포터블 진단장치를 개발하였다. 3개의 HFCT 센서를 사용하여 3상을 동시 측정할 수 있도록 하였다. 전원 분압 트리거 회로와 전류 변류 트리거 회로를 사용하여 위상 분석을 병행하였다. 실선로의 배전 케이블 부분방전 진단의 효율적 수행을 위해 개발된 본 장비를 현장 적용하였으며 내장된 PRPD 분석법이 가능하였으며 S/W 노이즈 게이팅을 적용하여 다른상에서 유기되는 신호를 제거하여 진단결과의 신뢰성을 높일 수 있었다.

  • PDF

Fault Diagnosis Technology of Power Supply Insulation System in Metro Substation (도시철도 절연기기의 진단데이터 획득 기술)

  • Park, Young;Jung, Ho-Sung;Kim, Hyung-Chul;Oh, Seok-Yong;Song, Joon-Tae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.266-266
    • /
    • 2009
  • This paper describes important parameters used to evaluate the insulation performance of power supply components in metro substations. For online fault diagnosis of power supply components, we have developed a new remote condition monitoring system using wireless technology. Our developed system can continuously monitor electric power equipment such as transformers, circuit brakers, and rectifiers and have powerful wireless networking functions.

  • PDF

Development of UV Corona Camera for the Detecting of Discharge on Power Facility using UV Transmittance Improvement Filter (UV 투과율 향상 필터 기술을 이용한 전력설비 방전 검출용 자외선 코로나 카메라 개발)

  • Kim, Young-Seok;Choi, Myeong-Il;Kim, Chong-Min;Bang, Sun-Bae;Shong, Kil-Mok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.11
    • /
    • pp.1656-1661
    • /
    • 2012
  • UV inspection technology is being used for predictive maintenance of power facility together with IR-thermography and ultrasonic devices. In this paper, the UV corona camera design, fabrication, and perform a simple test to be take advantage of the diagnostic equipment. The UV corona camera developed a $6.4^{\circ}{\times}4.8^{\circ}$ of the field of view as a conventional camera to diagnose a wide range of slightly enlarged, and power equipment to measure the distance between the camera and the distance meter has been attached. The transmission between 250 to 280nm was 11% ($12.5%{\times}88%{\times}98%$) by combing the transmission on absorption film, window and other filter(UG 5, nickel sulphate and so on). In a distance of 5m with the UV corona camera it is possible to detect partial discharge with a PD level of 2.5pC and a RIV level of $3.6dB{\mu}V$.

The Development of Infrared Thermal Imaging Safety Diagnosis System Using Pearson's Correlation Coefficient (피어슨 상관계수를 이용한 적외선 열화상 안전 진단 시스템 개발)

  • Jung, Jong-Moon;Park, Sung-Hun;Lee, Yong-Sik;Gim, Jae-Hyeon
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.6
    • /
    • pp.55-65
    • /
    • 2019
  • With the rapid development of the national industry, the importance of electrical safety was recognized because of a lot of new electrical equipment are installing and the electrical accidents have been occurring annually. Today, the electrical equipments is inspect by using the portable Infrared thermal imaging camera. but the most negative element of using the camera is inspected for only state of heating, the reliable diagnosis is depended with inspector's knowledge, and real-time monitoring is impossible. This paper present the infrared thermal imaging safety diagnosis system. This system is able to monitor in real time, predict the state of fault, and diagnose the state with analysis of thermal and power data. The system consists of a main processor, an infrared camera module, the power data acquisition board, and a server. The diagnostic algorithm is based on a mathematical model designed by analyzing the Pearson's Correlation Coefficient between temperature and power data. To test the prediction algorithm, the simulations were performed by damaging the terminals or cables on the switchboard to generate a large amount of heat. Utilizing these simulations, the developed prediction algorithm was verified.

A Study of the Preventive Diagnostic Algorithm of Gas Analysis in Oil for Power Transformer (가스분석을 이용한 전력용 변압기 이상진단 연구)

  • Choi, I.H.;Kweon, D.J.;Jung, G.J.;You, Y.P.;Sun, J.H.;Shin, M.C.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1676-1678
    • /
    • 2001
  • In general, power demand is on an increasing trend as industries have made rapid strides. Power transformer is the most important equipment in substation for this reason. Transformer trobles go with blackout, expensive repair costs and huge economic losses. Therefore it is important to find the quick detection of incipient fault for the least losses. There have been gas, partial discharge, temperature, OLTC, fan and pump diagnosis for preventive techniques by present. Specially gas analysis has been adapted for a long time and proved as confident method. In this paper, we analysed the fault causes of used power transformer. The insulation faults was occupied 40% of inquired 152 faults from 1991 to 2000. This study presents the developed algorithm and expert system for finding abnormal status within transformer. We used the Element Expert tool developed Neuron DATA Inc.

  • PDF

A Study on the Development of Corrosion Detecting System for 22.9 kV Distribution Power Line Insulation Cable (22.9kV 배전선로 절연전선의 부식 검출 시스템 개발에 대한 연구)

  • Kim, Yong-Jun;Oh, Yong-Cheul;Yi, Keon-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.7
    • /
    • pp.1410-1416
    • /
    • 2011
  • A corrosion detecting system for 22.9 kV distribution power line insulation cable, which can travel autonomously along the live line, is proposed. Eddy current test method is employed to detect the corrosion, and the system developed here is capable of detecting internal corrosion of a ACSR-OC. Somewhat details of the electrical and mechanical mechanism of the system and traveling algorithm are introduced. Experimental results applied to the sample cables having artificial corrosion and the operating distribution lines are provided. From the result, we confirmed that the system is useful for detecting internal corrosion of a ACSR, and is expected to be a new non-destructive testing equipment in the area of diagnosis for the distribution power line.

Trouble prediction of Thyristor Rectifiers by the method of heat distribution survey (열분포측정에 의한 정류회로 고장예측)

  • Park, Ho-Cheul
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.818-820
    • /
    • 1993
  • In the three phase full-wave thyristor rectifier, heat radiation concentrated at a few thyristor(s), while equipment's output is normal. That is very important on the predictive maintenance or checking including replacement of parts(or modules). Therefore, this report explains the method of effective diagnosis and the reason that firing control modules have to be adjusted accuratly on each phase.

  • PDF