• Title/Summary/Keyword: Power Distribution Systems

검색결과 1,306건 처리시간 0.034초

Computation of the Current Limiting Behavior of BSCCO-2212 High-Temperature Superconducting Tube with Shunt Coils

  • Kim, H.M.;Park, K.B.;Lee, B.W.;Oh, I.;Sim, J.;Hyun, O.B.
    • Progress in Superconductivity and Cryogenics
    • /
    • 제8권4호
    • /
    • pp.22-25
    • /
    • 2006
  • This paper deals with the computation of the current limiting behavior of high-temperature superconducting (HTS) modules for the superconducting fault current limiter (SFCL). The SFCL module consists of a monofilar type BSCCO-2212 tube and a shunt coil made of copper or brass. The shunt coil is connected to the monofilar superconducting tube in parallel. Through analysis of the quench behavior of the monofilar component with shunt coils, it is achieved to drive an equivalent circuit equation from the experimental circuit structure. In order to analyze the quench behavior of the SFCL module, we derived a partial differential equation technique. Inductance of the monofilar component and the impedance of the shunt coil are calculated by Bio-Savart and Ohm's formula, respectively. We computed the quench behavior using the calculated values, and compared the results with experimental results for the quench characteristics of a component. The results of computation and test agreed well each other, and it was concluded that the analytic result could be applied effectively to design of the distribution-level SFCL system.

Analysis of operation performance of PHILS-based superconducting current limiter connected to MVDC system

  • Seok-Ju Lee;Jae In Lee
    • Progress in Superconductivity and Cryogenics
    • /
    • 제25권4호
    • /
    • pp.54-59
    • /
    • 2023
  • In this paper, we analyze experimental results by applying the PHILS model to a lab-scale superconducting current limiter system for its actual application in medium-voltage direct current (MVDC) systems. Superconducting current limiters exhibit effective current-limiting performance in circuit breaker operations, particularly in limiting large fault currents within a short period, addressing the challenges posed by the increasing use of renewable energy and the integration of DC medium-voltage distribution systems. The development of such superconducting current limiters faces various technical and cost disadvantages, especially when applying a medium-voltage 35kV level system, which is intended for future introduction. The proven lab-scale superconducting current limiter system and the PHILS model are combined and integrated into the actual system. Our plan involves analyzing the limiter's performance, assessing its impact on the system, and preparing for its application in future medium-voltage systems. Utilizing RTDS, a simulation was conducted by connecting actual scaled-down equipment and systems, with the analysis results presented.

A Study on Optimization of Spray Type Flue Gas Desulfurization (FGD) System (모사 탈황흡수탑을 이용한 Spray Type 탈황설비 최적운전 방안에 관한 연구)

  • An, Hi-Soo;Park, Seung-Soo;Kim, Ki-Hyoung;Kim, Young-Ho
    • Applied Chemistry for Engineering
    • /
    • 제18권1호
    • /
    • pp.29-35
    • /
    • 2007
  • Recently, due to narrow margin on design factor of flue gas desulfurization (FGD) systems or aging of systems, some problems such as decrease of $SO_2$ removal efficiency and difficulty on coping with unstable state are arising on FGD systems. On this study, to cope with these problems several methods such as adjustment of reagent pH, inlet $SO_2$ concentration, variation of units of operation pump, installation of liquid distribution ring (LDR) were attempted to increase the $SO_2$ removal using spray type simulated FGD system. Also, sulfite and Al/Fx ion effects on limestone blinding were experimented. When three absorber recirculation pumps were operated, $SO_2$ removal was increased by 12% in comparison with that of two pumps operation. $SO_2$ removal was increased by 2~7% after installation of LDR. Dissolved oxygen increased up to 0.5 ppm and limestone binding effect was alleviated after injection of dibasic acid (DBA) with the concentration of 500 and 1,000 ppm. When $Al^{3+}$ and $F^-$ ions were coexisting, the dissolution rate of limestone was decreased by 20%.

Design of the 1.5kVA Class Wireless Power Transfer Device for Battery Charging of Integrated Power Control System in MSAP (군 이동기지국시스템(MSAP) 통합전원제어장치 배터리 충전용 1.5kVA급 무선전력전송기기의 설계)

  • Kim, Jin-Sung;Kim, Byung-Jun;Park, Hyeon-Jeong;Seo, Min-Sung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • 제15권3호
    • /
    • pp.413-420
    • /
    • 2020
  • The Tactical Information and Communication Network system provides real-time multimedia services such as voice and data by utilizing the Mobile Subscriber Access Point. At this time, an external transmission path is constructed through the Low Capacity Trunk Radio and the High Capacity Trunk Radio system. The communication devices of each wireless transmission system are mounted on a tactical vehicle and a secondary battery is used to prevent a power interruption when the supply power to the tactical vehicle is transferred to the integrated power control device. In this paper, the basic design of the Wireless Power Transfer device for charging the battery of the integrated power control system of the mobile base station system using the Loading Distribution Method and checking the number of primary windings and the core material selection by the air gap through the Finite Elements Method.

Design of an Algorithm for the Validation of SCL in Digital Substations

  • Jang, B.T.;Alidu, A.;Kim, N.D.
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제3권2호
    • /
    • pp.89-97
    • /
    • 2017
  • The substation is a critical node in the power network where power is transformed in the power generation, transmission and distribution system. The IEC 61850 is a global standard which proposes efficient substation automation by defining interoperable communication and data modelling techniques. In order to achieve this level of interoperability and automation, the IEC 61850 (Part 6) defines System Configuration description Language (SCL). The SCL is an XML based file format for defining the abstract model of primary and secondary substation equipment, communications systems and also the relationship between them. It enables the interoperable exchange of data during substation engineering by standardizing the description of applications at different stages of the engineering process. To achieve the seamless interoperability, multi-vendor devices are required to adhere completely to the IEC 61850. This paper proposes an efficient algorithm required for verifying the interoperability of multi-vendor devices by checking the adherence of the SCL file to specifications of the standard. Our proposed SCL validation algorithm consists of schema validation and other functionalities including information model validation using UML data model, the Vendor Defined Extension model validation, the User Defined Rule validation and the IED Engineering Table (IET) consistency validation. It also integrates the standard UCAIUG (Utility Communication Architecture International Users Group) Procedure validation for quality assurance testing. Our proposed algorithm is not only flexible and efficient in terms of ensuring interoperable functionality of tested devices, it is also convenient for use by system integrators and test engineers.

Environmental Impact Evaluation for the Power Generation System Using the LCA Methodology (LCA 기법을 이용한 발전시스템의 환경성 평가)

  • Ko, Kwang-Hoon;Hwang, Yong-Woo;Park, Kwang-Ho;Jo, Hyun-Jung;Jae, Moo-Sung
    • Journal of Korean Society of Environmental Engineers
    • /
    • 제27권7호
    • /
    • pp.704-711
    • /
    • 2005
  • In this study, life cycle assessment(LCA) for the nuclear power generation system and the thermal power generation system, which make a great distribution of the electric power supply in Korea, has been carried out to compare the environmental impact between two power generation systems. In system boundary of this study, the stage of construction, operation and demolition & disposal were included. For life cycle impact assessment(LCIA), three cases were considered; the single environmental impact for the $CO_2$ emissions, the 8 major global environmental impact, and the major global environmental impact categories including radioactive impact. As the results, it was found that the nuclear power generation system is environmentally superior to the thermal power generation system as 10,000 times in the evaluation for the $CO_2$ emissions, 90 times in the evaluation for the 8 major environmental impact categories, and 40 times in the evaluation for the environmental impact categories including radioactive impact.

Implementation of Noise Reduction Methodology to Modal Distribution Method

  • Choi, Myoung-Keun
    • Journal of Ocean Engineering and Technology
    • /
    • 제25권2호
    • /
    • pp.1-6
    • /
    • 2011
  • Vibration-based Structural Health Monitoring (SHM) systems use field measurements of operational signals, which are distorted by noise from many sources. Reducing this noise allows a more accurate assessment of the original "clean" signal and improves analysis results. The implementation of a noise reduction methodology for the Modal Distribution Method (MDM) is reported here. The spectral subtraction method is a popular broadband noise reduction technique used in speech signal processing. Its basic principle is to subtract the magnitude of the noise from the total noisy signal in the frequency domain. The underlying assumption of the method is that noise is additive and uncorrelated with the signal. In speech signal processing, noise can be measured when there is no signal. In the MDM, however, the magnitude of the noise profile can be estimated only from the magnitude of the Power Spectral Density (PSD) at higher frequencies than the frequency range of the true signal associated with structural vibrations under the additional assumption of white noise. The implementation of the spectral subtraction method to MDM may decrease the energy of the individual mode. In this work, a modification of the spectral subtraction method is introduced that enables the conservation of the energies of individual modes. The main difference is that any (negative) bars with a height below zero after subtraction are set to the absolute value of their height. Both noise reduction methods are implemented in the MDM, and an application example is presented that demonstrates its effectiveness when used with a signal corrupted by noise.

Application of shear deformation theory for two dimensional electro-elastic analysis of a FGP cylinder

  • Arefi, M.;Rahimi, G.H.
    • Smart Structures and Systems
    • /
    • 제13권1호
    • /
    • pp.1-24
    • /
    • 2014
  • The present study deals with two dimensional electro-elastic analysis of a functionally graded piezoelectric (FGP) cylinder under internal pressure. Energy method and first order shear deformation theory (FSDT) are employed for this purpose. All mechanical and electrical properties except Poisson ratio are considered as a power function along the radial direction. The cylinder is subjected to uniform internal pressure. By supposing two dimensional displacement and electric potential fields along the radial and axial direction, the governing differential equations can be derived in terms of unknown electrical and mechanical functions. Homogeneous solution can be obtained by imposing the appropriate mechanical and electrical boundary conditions. This proposed solution has capability to solve the cylinder structure with arbitrary boundary conditions. The previous solutions have been proposed for the problem with simple boundary conditions (simply supported cylinder) by using the routine functions such as trigonometric functions. The axial distribution of the axial displacement, radial displacement and electric potential of the cylinder can be presented as the important results of this paper for various non homogeneous indexes. This paper evaluates the effect of a local support on the distribution of mechanical and electrical components. This investigation indicates that a support has important influence on the distribution of mechanical and electrical components rather than a cylinder with ignoring the effect of the supports. Obtained results using present method at regions that are adequate far from two ends of the cylinder can be compared with previous results (plane elasticity and one dimensional first order shear deformation theories).

A Campus Community-based Mobility Model for Routing in Opportunistic Networks

  • Pan, Daru;Fu, Min;Sun, Jiajia;Zou, Xin
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제10권3호
    • /
    • pp.1034-1051
    • /
    • 2016
  • Mobility models are invaluable for determining the performance of routing protocols in opportunistic networks. The movement of nodes has a significant influence on the topological structure and data transmission in networks. In this paper, we propose a new mobility model called the campus-based community mobility model (CBCNM) that closely reflects the daily life pattern of students on a real campus. Consequent on a discovery that the pause time of nodes in their community follows a power law distribution, instead of a classical exponential distribution, we abstract the semi-Markov model from the movement of the campus nodes and analyze its rationality. Then, using the semi-Markov algorithm to switch the movement of the nodes between communities, we infer the steady-state probability of node distribution at random time points. We verified the proposed CBCNM via numerical simulations and compared all the parameters with real data in several aspects, including the nodes' contact and inter-contact times. The results obtained indicate that the CBCNM is highly adaptive to an actual campus scenario. Further, the model is shown to have better data transmission network performance than conventional models under various routing strategies.

A STUDY ON THE PROBABILISTIC PRODUCTION COST SIMULATION BY THE MIXTURE OF CUMULANTS APPROXIMATION (MIXTURE OF CUMULANTS APPROXIMATION 법에 의한 발전시뮬레이션에 관한 연구)

  • Song, K.Y.;Kim, Y.H.;Cha, J.M.
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.154-157
    • /
    • 1990
  • This paper describes a new method of calculating expected energy generation and loss of load probability (L.O.L.P) for electric power system operation and expansion planning. The method represents an equivalent load duration curve (E.L.D.C) as a mixture of cumulants approximation (M.O.C.A), which is the general case of mixture of normals approximation (M.O.N.A). By regarding a load distribution as many normal distributions-rather than one normal distribution-and representing each of them in terms of Gram-Charller expansion, we could improve the accuracy of results. We developed an algorithm which automatically determines the number of distribution and demarcation points. In modelling of a supply system, we made subsets of generators according to the number of generator outage: since the calculation of each subset's moment needs to be processed rapidly, we futher developed specific recursive formulae. The method is applied to the test systems and the results are compared with those of cumulant, M.O.N.A and Booth-Baleriaux method. It is verified that the M.O.C.A method is faster and more accurate than any other methods.

  • PDF