• Title/Summary/Keyword: Power Distribution Systems

Search Result 1,308, Processing Time 0.028 seconds

Development and Verification of Wireless Check-up System of POD for Captive Flight Test (탑재비행시험용 POD 무선 점검 시스템 개발 및 검증)

  • Ko, Myoungjun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.2
    • /
    • pp.204-210
    • /
    • 2021
  • In this paper, we studied a method of wirelessly checking up the POD for captive flight tests which is performed during the development of guided weapons systems. The wireless power transfer module, the power distribution device, and the battery pack were designed to wirelessly power the captive flight test POD, and the communication device was designed to enable wireless communication between the POD and the check-up device. The communication device was designed to enable WiFi, IR communication, and laser diode communication, so that various communication methods could be tested. Through the performance test, it was confirmed that power was stably supplied to the captive flight test POD, and the wireless communication performance was verified by measuring the delay time and error rate. As a result, by using our system the POD check-up for the captive flight test was performed wirelessly and the data of the captive equipment could be obtained effectively.

Reactive Power Variation Method for Anti-islanding Using Digital Phase-Locked-Loop (DPLL을 이용한 능동적 단독운전방지를 위한 무효전력변동법)

  • Lee, Ki-Ok;Yu, Byung-Gu;Yu, Gwon-Jong;Choi, Ju-Yeop;Choy, Ick
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.2
    • /
    • pp.64-69
    • /
    • 2008
  • As the grid-connected photovoltaic power conditioning systems (PVPCS) are installed in many residential areas, these have raised potential problems of network protection on electrical power system. One of the numerous problems is an Islanding phenomenon. There has been an argument that it may be a non-issue in practice because the probability of islanding is extremely low. However, there are three counter-arguments: First, the low probability of islanding is based on the assumption of 100% power matching between the PVPCS and the islanded local loads. In fact, an islanding can be easily formed even without 100% power matching (the power mismatch could be up to 30% if only traditional protections are used, e.g. under/over voltage/frequency). The 30% power-mismatch condition will drastically increase the islanding probability. Second, even with a larger power mismatch, the time for voltage or frequency to deviate sufficiently to cause a trip, plus the time required to execute a trip (particularly if conventional switchgear is required to operate), can easily be greater than the typical re-close time on the distribution circuit. Third, the low-probability argument is based on the study of PVPCS. Especially, if the output power of PVPCS equals to power consumption of local loads, it is very difficult for the PVPCS to sustain the voltage and frequency in an islanding. Unintentional islanding of PVPCS may result in power-quality issues, interference to grid-protection devices, equipment damage, and even personnel safety hazards. Therefore the verification of anti-islanding performance is strongly needed. In this paper, improved RPV method is proposed through considering power quality and anti-islanding capacity of grid-connected single-phase PVPCS in IEEE Std 1547 ("Standard for Interconnecting Distributed Resources to Electric Power Systems"). And the simulation results are verified.

Analytic Estimation of Interrupting capability on contact system in MCCB (배선용 차단기(MCCB) 차단성능 평가해석 기법)

  • Choi, Y.K.;Chong, J.K.;Kim, I.Y.;Park, I.H.;Hwang, G.C.;Lee, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.628-632
    • /
    • 2002
  • Low voltage circuit breakers which interrupt rapidly and raise the reliability of power supply are widly used in power distribution systems. In the paper, it was investigated how much Interrupting capability was improved by correcting the shape of the contact system in molded case circuit breaker(below MCCB), especially arc runner. Prior to the interrupting testing, it was necessary for the optimum design to analyze electromagnetic forces on the contact system, generated by current and flux density. This paper presents both our compuational analysis and test results on contact system in MCCB

  • PDF

DEVELOPMENT OF S-Z STRANDED NEUTRAL POWER CABLE (S-Z 중성선 전력 케이블의 개발)

  • Kim, J.W.;Pack, H.S.;Choi, Y.H.;Choi, M.K.;Kim, S.K.;Kim, J.C.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1296-1298
    • /
    • 1995
  • This paper presents the power cable with the concentric neutral wires of S-Z stranding. This type Cables, 22.9KV CN/CV Cables used in the distribution systems have been developed in order to improve bend, bend after torsion and tension charateristics. We have designed and made S-Z stranding machine, testing equipment etc., and have established the manufacturing technology of the equipment and the testing technology.

  • PDF

Determination of No-Failure Test Times for the Life Test of Hydraulic System Components (유압시스템 구성품의 수명시험을 위한 무고장 시험시간의 산출)

  • Lee, S.R.;Kim, H.E.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.3 no.3
    • /
    • pp.8-13
    • /
    • 2006
  • It is very important for the manufacturers to predict the life of hydraulic system components according to the results of life tests. Since it takes too much time to test the hydraulic system components until failure, the no-failure test method is applied for the life test of them. If the shape parameter of Weibull distribution, the number of samples, the confidence level, and the assurance life are given, the no-failure test times of hydraulic system components can be calculated by given equation. Here, the procedures to obtain the no-failure test times of the hydraulic system components such as hydraulic motors and pumps, hydraulic cylinders, hydraulic valves, hydraulic accumulators, hydraulic hoses, and hydraulic filters are described briefly.

  • PDF

The Development of the Train Performance Simulation Program for Railway Vehicles equipped with Energy Storage System (에너지 저장장치를 탑재한 철도차량의 소비에너지 시뮬레이션 프로그램 개발)

  • Oh, Yong-Kuk;Lee, Jee-Ho;Kwak, Jae-Ho;Hwang, Hyeon-Cheol
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2336-2341
    • /
    • 2011
  • The studies on railway vehicles equipped with various energy storage system is proceeded actively. These have a lot of advantages like the maximizing reuse of the regeneration energy, the decrease of peak power in catenary and the reduction of infrastructure costs through catenary-free travelling. This paper is focused on the development of the TPS (Train Performance Simulation) program for railway vehicles equipped with energy storage system. The battery and ultra-capacitor system are modeled using Matlab/Simulink among several energy storage systems. And the feasibility of simulation model is evaluated with the basic power distribution algorithm.

  • PDF

Analysis of Risk Assessment Factors for Gas leakage and Dispersion in Underground Power Plant (지하복합발전플랜트 내의 가스 누출 및 확산에 의한 위험성 평가 인자 분석)

  • Choi, Jinwook;Li, Longnan;Park, Jaeyong;Sung, Kunhyuk;Lee, Seonghyuk;Kim, Daejoong
    • Journal of ILASS-Korea
    • /
    • v.20 no.2
    • /
    • pp.101-106
    • /
    • 2015
  • Gas leakage and dispersion in the underground LNG power plant can lead to serious fire and explosion accident. In this study, computational fluid dynamics simulation was applied to model the dynamic process of gas leakage and dispersion phenomena in a closed space. To analyze the risk assessment factor, such as the flammable volume ratio, transient simulations were carried out for different scenarios. The simulation results visualized the gas distribution with time in the closed space. The flammable volume ratio was introduced for quantitative analysis the fire/explosion probability.

Characteristics Analysis of Induction Motor by Operation of Non-lineal Loads (비선형 부하의 운전시 유도전동기의 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2006.10b
    • /
    • pp.147-153
    • /
    • 2006
  • Voltage unbalance will be generated by the load unbalance operation such as combination operation of single & three phase load and current unbalance will be more severe by the deteriorated voltage quality. Under the these unbalance conditions, all power electronic converters used in different types of electronic systems can increase harmonic disturbances by injecting harmonic currents directly into the feeder grid of three phase 4-wire. Harmonic current may cause torque to decrease. it may also overheat or become noisy and torque oscillation in the rotor can lead to mechanical resonance and vibration. This paper presents a scheme on the characteristics of induction motor under the combination of linear & non-linear loads at the three phase 4-wire power distribution system by the unbalance and harmonic components. It was able to confirm that the number of torque pulsation decreased and torque ripple values increased by the harmonics that reduction was difficult by five harmonics filters at additional driving time of single-phase non-linear load.

  • PDF

Design of Advanced Static Var Compensator(ASVC) for Distribution Line (배전선로 적용을 위한 새로운 무효전력보상치(ASVC)의 설계)

  • Min, Wan-Ki;Lee, Sang-Hun;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2010-2012
    • /
    • 1997
  • A cascade multilevel voltage source inverter is introduced to apply the advanced static var compensator(ASVC) for large scale power application. This cascade M-level inverter consists of (M-1)/2 single-phase full bridges. This inverter is suitable to the flexible ac transmission systems(FACTS) including SVC, series compensation and phase shifting. It can solve the problems of conventional transformer -based multipulse inverters and multilevel diode-clamped inverters. From the simulation results, the validity of ASVC with cascade multilevel inverter is shown for high power application.

  • PDF

Formation of Skin Lotions Using Various Vehicles and Skin Hydration Effects for a Skin (다양한 제형을 활용한 화장수의 제조와 보습효과)

  • Cho, Wan-Goo;Kim, Su-Jeong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.124-131
    • /
    • 2009
  • We have produced, characterized and compared different colloidal vehicles based on nanoemulsions. We also have investigated morphology and droplet distribution by means of electron microscope and photon correlation spectroscopy. Nanoemulsion systems characterized by different method on formulations have been obtained. Hydration power has been studied by means of a corneometer, measuring the skin electrical capacitance before and after the application of various type of skin lotions. It has been demonstrated that nanoemulsion with oil or fatty alcohol displayed a pronounced hydration power with respect to the solubilization system. In order to compare the smoothness of the skin after using skin lotion, we have measured the friction force. The skin lotions produced by nanoemulsion technique show improved smoothness of an atopic skin.