A Study on the Simulator of Voltage Regulator for Distribution Systems interconnected with New Energy Power Sources (신에너지전원이 연계된 배전계통의 전압조정장치 시뮬레이터에 의한 수용가전압 평가)

  • Park, O-Seong;Sohn, Joon-Ho;Kim, Chang-Hyeok;Rho, Dae-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.513_514
    • /
    • 2009
  • 본 논문에서는 태양광, 풍력 등의 신에너지전원이 배전계통에 연계되어 운용되는 경우, 수용가의 전압이 규정전압 이내로 유지되는가를 평가할 수 있는 배전용변전소의 전압조정장치인 ULTC(Under Load Tap Changer)의 시뮬레이터를 제작하였다. 즉, 부하변동에 따라 전압조정장치의 동작을 모의할 수 있는 시뮬레이터를 이용하여, 신에너지 전원의 운용이 배전계통에 끼치는 영향을 평가하고 최적운용 방안을 제시하였다.

  • PDF

Optimal Solution of Bi-Directional Protection Problem for New Energy Power Sources in Distribution Systems (신에너지전원이 연계된 배전계통의 양방향 보호협조 대책에 관한 연구)

  • Ji, Seong-Ho;Kim, Chang-Hyeok;Park, Hyeon-Seok;Rho, Dae-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.517_518
    • /
    • 2009
  • 최근 신에너지전원의 계통연계가 점차 증가하고 있는 실정이지만, 신에너지전원 소유자의 보호방식은 기존 방식을 고수하고 있는 실정으로 신에너지전원의 역 조류에 의해 설치자의 보호기기(자동화기기 포함)의 오 부 동작 발생 가능성이 커지고 있다. 따라서 본 논문에서는 신에너지전원이 배전계통에 연계되어 운전되는 경우에 발생 가능한 보호협조의 문제점을 분석하고, 이에 대한 대책을 제시한다.

  • PDF

Analysis of Bi-Directional Protection Problem for New Energy Power Sources in Distribution Systems (신에너지전원이 연계된 배전계통의 양방향 보호협조 문제점 분석)

  • Lee, Beom-Tae;Kim, Chang-Hyeok;Rho, Dae-Seok;Wang, Yong-Peel;Jang, Young-Gil;Seo, Soon-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.515_516
    • /
    • 2009
  • 최근 배전계통에 연계되고 있는 신에너지전원의 용량은 점차 증가하고 있는 상황이지만, 설치자(신에너지전원 소유자)의 보호방식은 기존 방식을 고수하고 있는 실정으로 분산전원의 역 조류에 의해 설치자의 보호기기(자동화기기 포함)의 오 부 동작 발생 가능성이 커지고 있다. 본 논문에서는 신에너지전원이 배전계통에 연계되어 운전되는 경우에 발생 가능한 보호협조의 문제점을 분석한다.

  • PDF

Development of Fault Analysis Evaluation System for Dispersed Power Sources in Distribution Systems (분산전원 설치시의 사고해석 및 평가시스템 개발)

  • Rho, Dae-Seok;Kim, Chang-Hyeok;Wang, Yong-Peel;Jang, Young-Gil;Seo, Soon-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.432_433
    • /
    • 2009
  • 분산전원의 소유자(발전사업자) 및 시공하는 공사업체들은 배전계통에 분산전원을 설치하고 운용할 때, 보호방식에 대한 상세한 검토 없이 연계공사를 추진하여, 많은 문제점에 부닥치고 있는 실정이다. 이들 복잡한 기술적 고려사항을 정확하게 파악하기 위해서, 한전에서 정한 계통연계기술 지침과 관련 해설서 등을 모두 이해해야 하는데, 발전사업자나 시공업자가 수권의 분량을 모두 해석하고 이해하기에는 어려운 점이 있다. 분산전원의 역 조류에 의하여 분산전원의 설치 공사 후, 운용상에 많은 문제점이 유발되고 있는 실정이다. 특히 계통 측의 사고나 분산 전원 소유자의 사고 발생 시에 다른 수용가에게 피해를 끼치는 사례들이 보고되고 있다. 따라서 본 연구에서는 분산전원의 보호 협조에 예상되는 기술적인 문제점을 자동적으로 검토, 분석할 수 있는 사고해석 자동평가시스템을 개발하였다.

  • PDF

An Intelligent Fault Detection and Service Restoration Scheme for Ungrounded Distribution Systems

  • Yu, Fei;Kim, Tae-Wan;Lim, Il-Hyung;Choi, Myeon-Song;Lee, Seung-Jae;Lim, Sung-Il;Lee, Sung-Woo;Ha, Bok-Nam
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.3
    • /
    • pp.331-336
    • /
    • 2008
  • Electric load components have different characteristics according to the variation of voltage and frequency. This paper presents the load modeling of an electric locomotive by the parameter identification method. The proposed method for load modeling is very simple and easy for application. The proposed load model of the electric locomotive is represented by the combination of the loads that have static and dynamic characteristics. This load modeling is applied to the KTX in Korea to verify the effectiveness of the proposed method. The results of proposed load modeling by the parameter identification follow the field measurements very exactly.

Development of a Method to Analyze Voltage Sag Monitoring Data (순간전압강하 모니터링 데이터 분석 방법)

  • Park, Chang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.4
    • /
    • pp.16-22
    • /
    • 2013
  • This paper presents a method to analyze the voltage sag data obtained from monitoring systems. In order to establish effective countermeasures against voltage sag problems, an assessment of the system performance with respect to voltage sags is needed. Generally, the average annual sag frequency can be estimated by using the recorded voltage sag events for several years. However, the simple average value can not give the information about the errors of estimation. Such an average estimation is not useful for establishing effective solutions for voltage sag problems. Therefore, this paper proposes an effective method based on the Interval Estimation method. The estimation of voltage sag frequency is performed by using the average frequency and Poisson probability model. The proposed method can give the expected annual sag frequency and upper one-sided bound frequency.

Effect of the Salinity Level on Tracking Characteristics of Polymer Insulators (폴래머애자의 트래킹 특성에 미치는 염수농도의 영향)

  • 한재홍;송일근;김동명;정종욱
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.74-77
    • /
    • 2001
  • In order to investigate the effect of salinity level on tracking characteristics of polymer insulators for distribution power systems, tracking tests were performed by tracking wheel tester under different salt concentration. In this study, 6 kinds of polymer insulators were tested under 2200 ${\mu}\textrm{s}$/cm and 4000${\mu}\textrm{s}$/cm salinity. The salinity level has a significant effect on the tracking characteristics. Namely, most polymer insulators showed the good tracking resistance in case of low salinity level. But, in case of high salinity level some polymer insulators showed the excessive erosion and tracking. These phenomena may come from the different aging mechanism. It can be concluded that too high salinity level is not desirable in aging test of polymer insulators.

  • PDF

New Control Technique of Active Power Filter to Cancel Neutral Current Harmonics in Three-Phase Four-Wire Electric Distribution Systems (3상 4선식 배전계통에서 중성선 전류 고조파의 제거를 위한 능동전력필터의 새로운 제어기술)

  • Choi, Se-Wan;Jang, Min-Soo;Kim, Tae-Hoon;Kim, Ki-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.1123-1125
    • /
    • 2001
  • 최근 스위칭 전원장치를 사용하는 PC, UPS, 정류기 및 조명기기등 비선형부하의 증가에 따라 3상 4선식 배전계통에서 평형부하인 경우에도 중성선에 큰 고조파전류가 흘러 계통내 많은 문제를 야기하고 있다. 본 논문에서는 단상인버터에 의한 중성선전류 제어 기술 (6)로서 불평형하에서 기본파의 영상전류에 의해 필터장치에 과부하가 걸리는 것을 방지하기위한 새로운 제어기법을 제안하고 이론에 의한 분석과 모의실험 및 실험에 의하여 타당성을 입증한다.

  • PDF

Reliability Evaluation for Considering the Voltage Quality in Power Distribution Systems (전압품질을 고려한 배전계통의 신뢰도 평가)

  • Yun, Sang-Yun;Kim, Oun-Seok;Bae, Joo-Chun;Kim, Nark-Kyung;Park, Joong-Shin;Kim, Jae-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.525-527
    • /
    • 2000
  • This paper presents a reliability evaluation method for considering the voltage quality. The proposed evaluation methods are contained the sustained interruption, momentary interruption and voltage sag. For momentary interruption, evaluation indexes are divided the duration based index and the interruption cost index. For voltage sag, the final result of evaluation method represents the magnitude for customers' risk due to the voltage sag. The proposed method is tested using the RBTS model and a reliability data in KEPCO's system.

  • PDF

Technical Analysis for Small Hydro-power Generator Integrated with Electric Distribution Systems (소수력발전의 배전계통 연계를 위한 기술적 분석)

  • Jung, Won-Wook;Kim, Sang-Jun;Yoon, Ki-Gab;Seo, Jung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.529-530
    • /
    • 2006
  • 분산형 전원이 전력계통에 연계됨에 따라 역조류, 보호협조, 계통 동기화, 전기품질 문제 등 여러 가지 문제를 야기한다. 이에 따라 전력회사에서는 분산형 전원의 계통연계 기술 기준을 제시하고 해당 분산형 전원의 계통 연계에 대한 기술 검토를 수행한다. 본 논문에서는 동기발전기형 2500KVA 소수력발전기 2대의 배전계통 연계에 대한 기술적 검토를 수행하였으며 해당 분산형 전인이 동기발전기임을 고려하여 계통연계시 상시전압변동 및 보호방식에 대해 집중 분석하였다. 먼저 소수력발전기가 연계되는 지점에서의 기존 선로 및 전력설비의 여건과 소수력발전기의 출력용량 및 역률을 고려하여 연계 지점에서의 전압변동을 검토하여 적절한 연계방식을 제시한다. 그리고 시간대별 소수력발전기의 발전량과 해당 배전선로의 부하량을 고려하여 기 설치된 보호계전기에 의한 단독운전 검출 능력을 검토하고자 한다.